Termometru digital portabil termocuplu K J T E Delta Ohm HD2328.0

Cod: Delta Ohm HD2328.0


 

Brosura produs PDF, 0.2 Mb
 

Descriere

Thermocouple thermometer for probes type K, J, T, E. Two inputs for miniature thermocouple connectors. Storage of maximum, minimum, average value. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree. Complete with carrying case, instruction manual, 3 batteries, the probes have to be ordered separately. All the thermocouples type K available in this price-list at page 108 can be connected.

 

Alte produse SENSECA

PH-METRU-CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR DELTA OHM HD3456.2

• Bench-top pHmeter-Conductivity meter-Thermometer
• measures pH, mV, ORP values by pH, redox or separated reference electrodes, conductivity,
• liquids resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

FOTO-RADIOMETRU PORTABIL CU DATALOGGER MASURA RADIATII OPTICE NECOERENTE CF DIRECTIVA EUROPEANA 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

TESTER MONITORIZARE SI ANALIZA CALITATE AER INTERIOR, MONOXID, BIOXID DE CARBON DELTA OHM HD37AB1347

• Datalogger for indoor air quality analysis (IAQ)
• measures: airspeed, temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide)
• Memory capacity of 67,600 records for each of the two inputs.
• Logging interval from 15 seconds to 1 hour.

 

APARAT MASURA SI INREGISTRARE PARAMETRI CO, CO2, PRESIUNE ATMOSFERICA, TEMPERATURA, UMIDITATE DELTA OHM HD21AB HD21AB17

• Carbon Dioxide CO2
• Carbon Monoxide CO
• Atmospheric Pressure
• Temperature
• Relative Humidity
• Dew Point, Wet Bulb Temperature, Absolute Humidity, Mixing Ratio, Enthalpy

 

SONOMETRU INTEGRATOR PORTABIL DE CLASA I CU ANALIZA SPECTRU OCTAVA SI STATISTICI DELTA OHM HD2010

• precision integrating portable sound level meter
• data logging functions
• performing both spectrum and statistical analysis
• maximum flexibility and simplicity
• firmware can be directly updated by the user by means of the Noise Studio program supplied with the instrument
• Class 1 sound level meter according to IEC 61672-1, 2002
• Class 1 octave and third octave filters according to IEC 61260
• Microphone complying with IEC 61094-4
• Noise monitoring and optional capture and analysis of sound events
• Octave and optional third octave band spectrum analysis from 16 Hz to 20 kHz

 

ANALIZOR AUDIO SUNET CLASA I CU DATALOGGER, ANALIZA SPECTRU ACUSTIC OCTAVA 3A, STATISTICI DELTA OHM HD2110L

• precision integrating portable sound level meter
• data logging function
• performing both spectrum and statistical analysis
• high-performance analysis of acoustic phenomena
• Class 1 sound level meter according to IEC 61672-1, 2002 , IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Real-time octave and third octave band spectrum analysis from 16 Hz to 20 kHz
• Narrow-band spectral analysis (FFT) with variable resolution from 1.5Hz to 100Hz and capture of the Leq profile at intervals of 1/32s

 

TESTER LABORATOR PARAMETRI ELECTROCHIMICI OXIGEN DIZOLVAT CONCENTRATIE INDEX SATURATIE DELTA OHM HD3409.2

• Bench-top Oxymeter-Thermometer measures dissolved oxygen,
• saturation index by polarographic type combined probes,
• temperature by Pt100 probes with SICRAM module.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

DATALOGGER ANALIZOR MICRO-CLIMA WBGT DELTA OHM HD32.2 HD32.2A

• analysis of WBGT index (Wet Bulb Glob Temperature: wet bulb temperature and globe thermometer temperature) in presence or in absence of solar radiation
• Logging
• data transfer speed via the RS232 serial port
• The measurement unit of the temperature: °C, °F, °K
• Date and time of the instrument
• display of maximum, minimum, medium statistic parameters and their deletion

 

ANEMOMETRU TERMOMETRU MASURA VITEZA AER DELTA OHM HD2303.0

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

DATALOGGER PRESIUNE, TEMPERATURA, DEBIT DELTA OHM DO9704

• Datalogger for pressure, flow rate and temperature measurements with 2 inputs,
• memory 512 Kbytes,
• storage of maximum, minimum and average value.
• RS232 C output