Pirheliometru clasa intai masura iradiere directa flux solar Delta Ohm LP PIRHE16

Cod: Delta Ohm LP PIRHE16


 

Brosura produs PDF, 0.36 Mb

Descriere

The pyrheliometer LP PYRHE 16 (First Class Pyrheliometer according to ISO 9060

classification) is an instrument for direct measurement of solar irradiance (Watt/m2).

The receiving surface must be positioned (via a solar tracker or else) perpendicularly

to sun’s rays. By using suitable diaphragms only the direct light reaches the surface

of the sensor. According to WMO (Seventh Edition 2008) and ISO 9069 regulations,

the pyrheliometer has a field of view of 5°.

 

The pyrheliometer is produced in three versions:

LP PYRHE 16 PASSIVE

LP PYRHE 16 AC ACTIVE with 4..20mA CURRENT output

LP PYRHE 16 AV ACTIVE with 0..1V or 0..5V o 0..10V VOLTAGE output to be defined at the time of placing the order

 

Alte produse SENSECA

TERMOMETRU DE PRECIZIE PORTABIL DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2

• Centesimal thermometer in the range +/-199.99°C, decimal outside this range
• one input for Pt100 probes with SICRAM module measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power

 

DATALOGGER ANALIZOR MICRO-CLIMA WBGT PMV PPD DELTA OHM HD32.3 HD32.3A

• Analysis of hot environments using WBGT index
• Analysis of the moderate warm environments using PMV index and PPD index
• Logging
• Start and stop can be set automatically with the auto-start function
• Selectable measurement unit of the temperature: °C, °F, °K.
• Date and time of the instrument.

 

TURBIDIMETRU PORTABIL DE LABORATOR TESTARE LICHIDE PROCES, APA POTABILA, APE UZATE DELTA OHM HD25.2

• Portable and bench turbidity meter equipped with 3 photodetectors and two light sources
• it measures according to the standard EPA 180.1, ISO-NEPH (ISO 7027), EBC and ASBC.
• Automatic calibration,
• datalogger,
• data downloading to PC by RS232C or USB 2.0 through the software DeltaLog11

 

FOTO-RADIOMETRU PORTABIL CU DATALOGGER MASURA RADIATII OPTICE NECOERENTE CF DIRECTIVA EUROPEANA 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

DATALOGGER 8-16 CANALE INREGISTRARE TEMPERATURA DELTA OHM HD32.7 HD32.8.8 HD32.8.16

• HD32.7 - 8 INPUTS DATA LOGGER FOR pt100 SENSOR PROBES
• HD32.8.8/ HD32.8.16 Rugged data logger with 8/16 inputs for K, J, T, N, R, S, B and E type thermocouple with miniature connector temperature probes
• Unit of measurement °C, °F, °K configurable.
• Data logging: instantaneous or postponed, with the possibility of selecting the storage start and end.
• Data download: RS232C, 1200...38400 baud or USB 1.1 - 2.0.
• DeltaLog9 software for data download and processing.

 

MICRO MANOMETRU-TERMOMETRU DIGITAL DELTA OHM HD2114P HD2134P

• Micromanometer-Thermometer for air speed and flow rate measurement by means of Pitot tubes
• full scale 20mbar for speed measurements from 2...55m/s.
• Temperature measurement by K type thermocouple.
• Datalogger which stores the maximum, minimum, average value and can store up to 36,000 couples of samples.
• RS232C/ USB output for data transfer in real time to a PC or printer

 

LUXMETRU MASURA ILUMINANTA, PAR, IRADIANTA LUMINA SOLARA DELTA OHM HD2302.0 HD2302.0VP474

• Device for measuring illuminance, luminance, PAR, irradiance
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

SONDA RADIOMETRICA EXTERIOR MASURA IRADIANTA LUMINA SOLARA DELTA OHM LP UVA02

• Radiometric probe for outdoor use for measuring IRRADIANCE in the range UVA (315...400nm).
• mV per mW/cm2 output.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors

 

PH-METRU-TERMOMETRU DE LABORATOR CU MASURA PH, MV, POTENTIAL REDOX ORP DELTA OHM HD2205.2

• Bench-top pHmeter-Thermometer with back-lighted display,
• with two BNC inputs, to
• measure pH, mV, ORP with pH, redox, separated reference electrodes,
• one input for a pH/temperature combined probe provided with SICRAM module.
• Datalogger of pH, mV, temperature.
• RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time.
• Input for Pt100 or Pt1000 temperature probes provided with SICRAM module

 

ANALIZOR AUDIO SUNET CLASA I CU DATALOGGER, ANALIZA SPECTRU ACUSTIC OCTAVA 3A, STATISTICI DELTA OHM HD2110L

• precision integrating portable sound level meter
• data logging function
• performing both spectrum and statistical analysis
• high-performance analysis of acoustic phenomena
• Class 1 sound level meter according to IEC 61672-1, 2002 , IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Real-time octave and third octave band spectrum analysis from 16 Hz to 20 kHz
• Narrow-band spectral analysis (FFT) with variable resolution from 1.5Hz to 100Hz and capture of the Leq profile at intervals of 1/32s