Sonometru integrator Clasa I / Clasa II cu datalogging, analiza spectrala si statistica Delta Ohm HD2010UC/A

Cod: Delta Ohm HD2010UC/A


 

Brosura produs PDF, 0.46 Mb
       

Descriere

HD2010UC/A is a portable integrating class 1 sound level meter, with data logging function, suitable for performing statistical and spectral analyses The instrument has been designed by combining maximum flexibility and simplicity. Attention has been paid to the possibility of adjusting the instrument so to comply with the changes in the rules about noise and to the necessity of comply with the current and future requests of the
users. It is possible to add options to the HD2010UC/A so to extend its applications; the user can update the firmware directly by means of the Noise Studio programme supplied with the instrument.
Several kits are available, ready to use!

Technical regulations:

• Class 1 or 2 sound level meter according to IEC 61672-1, 2002 (Certificate of Compliance I.N.RI.M. No. 07-0124-02), IEC 60651 and IEC 60804.
• Class 1 octave and third octave filters according to IEC 61260.

Applications:
• Assessment of the environmental noise level,
• Noise monitoring and optional capture and analysis of sound events,
• Octave and optional third octave band spectrum analysis from 25 Hz to 12.5 kHz,
• Statistical analysis with the calculation of 3 percentile levels and optional full statistical analysis,
• Identification of impulsive noise,
• Measurements in workplaces,
• Selection of personal protective equipment (SNR, HML, and OBM methods),
• Sound insulation and reclamation,
• Production quality control,
• Measurement of machine noise,
• Optional architectural acoustics and building measurements.


Sound level meter Class 1 Kits:

HD2010UC/A kit1: consists of HD2010UC/A class 1 sound level meter , HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2), windscreen, 5m extension cable and serial
RS232 or USB connection cable. Noise Studio PC programme.

HD2010UC/A kit1/E: version for outdoor measurements, it consists of HD2010UC/A class 1 sound level meter, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated  preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme.

HD2010UC/A kit1/IE: version for indoor and outdoor measurements, it consists of HD2010UC/A class 1 sound level meter, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated
preamplifier, HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme.

 

 

HD2010UC/A is a portable integrating class 2 sound level meter, with data logging function, suitable for performing statistical and spectral analyses The instrument has been designed by combining maximum flexibility and simplicity. Attention has been paid to the possibility of adjusting the instrument so to comply with the changes in the rules about noise and to the necessity of comply with the current and future requests of the
users. It is possible to add options to the HD2010UC/A so to extend its applications; the user can update the firmware directly by means of the Noise Studio programme supplied with the instrument.
Several kits are available, ready to use!

Technical regulations:

• Class 2 sound level meter according to IEC 61672-1, 2002 (Certificate of Compliance I.N.RI.M. No. 07-0124-02), IEC 60651 and IEC 60804.
• Class 2 octave and third octave filters according to IEC 61260.

Applications:
• Assessment of the environmental noise level,
• Noise monitoring and optional capture and analysis of sound events,
• Octave and optional third octave band spectrum analysis from 25 Hz to 12.5 kHz,
• Statistical analysis with the calculation of 3 percentile levels and optional full statistical analysis,
• Identification of impulsive noise,
• Measurements in workplaces,
• Selection of personal protective equipment (SNR, HML, and OBM methods),
• Sound insulation and reclamation,
• Production quality control,
• Measurement of machine noise,
• Optional architectural acoustics and building measurements.


Sound level meter Class 2 Kits:

HD2010UC/A kit2: consists of HD2010UC/A class 2 sound level meter , HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2), windscreen, 5m extension cable and serial
RS232 or USB connection cable. Noise Studio PC programme.

HD2010UC/A kit2/E: version for outdoor measurements, it consists of HD2010UC/A class 2 sound level meter, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated  preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme.

HD2010UC/A kit2/IE: version for indoor and outdoor measurements, it consists of HD2010UC/A class 2 sound level meter, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated
preamplifier, HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme.

 

Accesorii standard

 

 

Alte produse SENSECA

PIRGEOMETRU METEO MASURA RADIATIE INFRAROSU DELTA OHM LP PIRG01

• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).
• Its use is mainly in the meteorological field.
• Measures are referred to radiations with wavelength greater than 4.5 µm .
• The far infrared radiation derives from the measure of the thermopile output signal and from the knowledge of the instrument temperature. The temperature measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.
• The pyrgeometer can be used also for the study of energy balance

 

RADIOMETRU NET RADIATIE SOLARA ULTRAVIOLETA-INFRAROSU DELTA OHM LP NET07

• LP NET 07 measures the net radiation across a surface, from near ultraviolet to
• far infrared.
• The Net radiation is defined as the difference between the radiation that reaches the upper surface and the irradiation on the lower surface of the net radiometer.
• The surface of the upper receiver measures the direct solar radiation plus the diffuse one and the radiation at longer wavelengths emitted from the sky (clouds), while the lower receiving area measures the solar radiation reflected from the ground (albedo) and the radiation length wavelengths emitted from the earth.
• The instrument is designed and constructed to be used outdoors in any weather
• conditions.

 

DATALOGGER FOTO-RADIOMETRU LUMINA SOLARA, TEMPERATURA DELTA OHM DO9721

• Datalogger Photo-radiometer Thermometer which performs photometric, radiometric, PAR, temperature measurements.
• Two inputs.
• Function as datalogger: 30,000 samples, REL, Record, Q (integration),
• RS232C serial output

 

PH-METRU-CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR DELTA OHM HD3456.2

• Bench-top pHmeter-Conductivity meter-Thermometer
• measures pH, mV, ORP values by pH, redox or separated reference electrodes, conductivity,
• liquids resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

PH-METRU-TERMOMETRU DE LABORATOR CU MASURA PH, MV, POTENTIAL REDOX ORP DELTA OHM HD2205.2

• Bench-top pHmeter-Thermometer with back-lighted display,
• with two BNC inputs, to
• measure pH, mV, ORP with pH, redox, separated reference electrodes,
• one input for a pH/temperature combined probe provided with SICRAM module.
• Datalogger of pH, mV, temperature.
• RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time.
• Input for Pt100 or Pt1000 temperature probes provided with SICRAM module

 

ANEMOMETRU ULTRASONIC MASURA VITEZA SI DIRECTIE VANT DOUA AXE DELTA OHM HD52.3

• 2 axes ultrasonic Anemometers series HD 52.3D
• Wind speed and direction, U-V Cartesian components of wind speed,
• Relative Humidity and Temperature (option, code "17"),
• Diffuse Solar Radiation (option, code "P"),
• Barometric pressure (option, code "4").

 

SONOMETRU INTEGRATOR CLASA I SI CLASA II CU ANALIZA SPECTRALA SI STATISTICA DELTA OHM HD2010UC

• integrating portable sound level meter performing statistical analysis
• maximum low cost and simplicity of use
• possibility of adjusting the instrument and adding options at any time
• user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument
• Class 1 or 2 sound level meter according to IEC 61672-1 dated 2002, IEC 60651 and IEC 60804
• Assessment of the environmental noise level,
• Optional "data logging" function,
• Optional capture and analysis of sound events,
• Statistical analysis with the calculation of 3 percentile level and optional full statistical analysis

 

TURBIDIMETRU PORTABIL DE LABORATOR TESTARE LICHIDE PROCES, APA POTABILA, APE UZATE DELTA OHM HD25.2

• Portable and bench turbidity meter equipped with 3 photodetectors and two light sources
• it measures according to the standard EPA 180.1, ISO-NEPH (ISO 7027), EBC and ASBC.
• Automatic calibration,
• datalogger,
• data downloading to PC by RS232C or USB 2.0 through the software DeltaLog11

 

DATALOGGER METEO CU ACHIZITIE SI INREGISTRARE DATE DELTA OHM HD32MT.1

• 16-channel data logger capable of capturing and logging the values measured by a series of sensors connected to its inputs
• Sensors with analog voltage output, both unipolar and bipolar
• Sensors with analog current output(0..20mA, 4..20mA)
• Temperature sensors thermocouple(typpe K, J, T, N, R, S, B, E)
• Pt100/Pt1000 and NTC temperature sensors
• Sensors with digital output TTL level pulse (ON/OFF)
• Sensors with open/close contact output(e.g. rain gauges, cup anemometers

 

ACCELEROMETRU MONO-AXIAL SI ACCELEROMETRU TRIAXIAL ICP VIBRATII MECANICE DELTA OHM

• HD356A02: tri-axial accelerometer for the measurement of vibrations transmitted to the handarm system
• HD356B21: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system
• HD356B41: tri-axial accelerometer inserted in a rubber pad for the measurement of the vibrations trasnmitted to the whole body
• HD356A22: tri-axial accelerometer for general application
• HD352C34: mono-axial accelerometer for general application
• HD356B20: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system at high shock level