Sonometru integrator Clasa I / Clasa II cu datalogging, analiza spectrala si statistica Delta Ohm HD2010UC/A

Cod: Delta Ohm HD2010UC/A


 

Brosura produs PDF, 0.46 Mb
       

Descriere

HD2010UC/A is a portable integrating class 1 sound level meter, with data logging function, suitable for performing statistical and spectral analyses The instrument has been designed by combining maximum flexibility and simplicity. Attention has been paid to the possibility of adjusting the instrument so to comply with the changes in the rules about noise and to the necessity of comply with the current and future requests of the
users. It is possible to add options to the HD2010UC/A so to extend its applications; the user can update the firmware directly by means of the Noise Studio programme supplied with the instrument.
Several kits are available, ready to use!

Technical regulations:

• Class 1 or 2 sound level meter according to IEC 61672-1, 2002 (Certificate of Compliance I.N.RI.M. No. 07-0124-02), IEC 60651 and IEC 60804.
• Class 1 octave and third octave filters according to IEC 61260.

Applications:
• Assessment of the environmental noise level,
• Noise monitoring and optional capture and analysis of sound events,
• Octave and optional third octave band spectrum analysis from 25 Hz to 12.5 kHz,
• Statistical analysis with the calculation of 3 percentile levels and optional full statistical analysis,
• Identification of impulsive noise,
• Measurements in workplaces,
• Selection of personal protective equipment (SNR, HML, and OBM methods),
• Sound insulation and reclamation,
• Production quality control,
• Measurement of machine noise,
• Optional architectural acoustics and building measurements.


Sound level meter Class 1 Kits:

HD2010UC/A kit1: consists of HD2010UC/A class 1 sound level meter , HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2), windscreen, 5m extension cable and serial
RS232 or USB connection cable. Noise Studio PC programme.

HD2010UC/A kit1/E: version for outdoor measurements, it consists of HD2010UC/A class 1 sound level meter, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated  preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme.

HD2010UC/A kit1/IE: version for indoor and outdoor measurements, it consists of HD2010UC/A class 1 sound level meter, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated
preamplifier, HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme.

 

 

HD2010UC/A is a portable integrating class 2 sound level meter, with data logging function, suitable for performing statistical and spectral analyses The instrument has been designed by combining maximum flexibility and simplicity. Attention has been paid to the possibility of adjusting the instrument so to comply with the changes in the rules about noise and to the necessity of comply with the current and future requests of the
users. It is possible to add options to the HD2010UC/A so to extend its applications; the user can update the firmware directly by means of the Noise Studio programme supplied with the instrument.
Several kits are available, ready to use!

Technical regulations:

• Class 2 sound level meter according to IEC 61672-1, 2002 (Certificate of Compliance I.N.RI.M. No. 07-0124-02), IEC 60651 and IEC 60804.
• Class 2 octave and third octave filters according to IEC 61260.

Applications:
• Assessment of the environmental noise level,
• Noise monitoring and optional capture and analysis of sound events,
• Octave and optional third octave band spectrum analysis from 25 Hz to 12.5 kHz,
• Statistical analysis with the calculation of 3 percentile levels and optional full statistical analysis,
• Identification of impulsive noise,
• Measurements in workplaces,
• Selection of personal protective equipment (SNR, HML, and OBM methods),
• Sound insulation and reclamation,
• Production quality control,
• Measurement of machine noise,
• Optional architectural acoustics and building measurements.


Sound level meter Class 2 Kits:

HD2010UC/A kit2: consists of HD2010UC/A class 2 sound level meter , HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2), windscreen, 5m extension cable and serial
RS232 or USB connection cable. Noise Studio PC programme.

HD2010UC/A kit2/E: version for outdoor measurements, it consists of HD2010UC/A class 2 sound level meter, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated  preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme.

HD2010UC/A kit2/IE: version for indoor and outdoor measurements, it consists of HD2010UC/A class 2 sound level meter, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated
preamplifier, HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme.

 

Accesorii standard

 

 

Alte produse SENSECA

PIRHELIOMETRU CLASA INTAI MASURA IRADIERE DIRECTA FLUX SOLAR DELTA OHM LP PIRHE16

• The pyrheliometer LP PYRHE 16 First Class Pyrheliometer according to ISO 9060 classification
• is an instrument for direct measurement of solar irradiance (Watt/m2).
• The receiving surface must be positioned (via a solar tracker or else) perpendicularly to sun’s rays.
• By using suitable diaphragms only the direct light reaches the surface of the sensor.
• According to WMO (Seventh Edition 2008) and ISO 9069 regulations, the pyrheliometer has a field of view of 5°.

 

MANOMETRU TERMOMETRU DIGITAL PORTABIL DELTA OHM HD2304.0

• Manometer-Thermometer with one input for SICRAM module PP471 to connect probes TP704 and TP705 series
• Temperature measurement with Pt100 probe complete with SICRAM module, measuring range 200°C +650°C.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

PIRGEOMETRU METEO MASURA RADIATIE INFRAROSU DELTA OHM LP PIRG01

• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).
• Its use is mainly in the meteorological field.
• Measures are referred to radiations with wavelength greater than 4.5 µm .
• The far infrared radiation derives from the measure of the thermopile output signal and from the knowledge of the instrument temperature. The temperature measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.
• The pyrgeometer can be used also for the study of energy balance

 

DATALOGGER ANALIZA MONITORIZARE CALITATE MEDIU AER, MONOXID, BIOXID CARBON DELTA OHM HD37AB17D HD37B17D

• data loggers able to measure and memorize simultaneously the following parameters:
• Relative Humidity RH
• Environment temperature T
• Carbon monoxide CO (only HD37AB17D)
• Carbon dioxide CO2
• DeltaLog13 communication software via the USB port

 

DATALOGGER ANALIZOR MICRO-CLIMA WBGT PMV PPD DELTA OHM HD32.3 HD32.3A

• Analysis of hot environments using WBGT index
• Analysis of the moderate warm environments using PMV index and PPD index
• Logging
• Start and stop can be set automatically with the auto-start function
• Selectable measurement unit of the temperature: °C, °F, °K.
• Date and time of the instrument.

 

FOTO-RADIOMETRU PORTABIL CU DATALOGGER MASURA RADIATII OPTICE NECOERENTE CF DIRECTIVA EUROPEANA 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

TERMOMETRU DE PRECIZIE PORTABIL DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2

• Centesimal thermometer in the range +/-199.99°C, decimal outside this range
• one input for Pt100 probes with SICRAM module measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power

 

TERMOMETRU DIGITAL PORTABIL TERMOCUPLU K J T E DELTA OHM HD2328.0

• Thermocouple thermometer for probes type K, J, T, E
• Two inputs for miniature thermocouple connectors
• Storage of maximum, minimum, average valu
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

ANALIZOR VIBRATII 4-CANALE PROTECTIE VIBRATII MECANICE LOC DE MUNCA DELTA OHM HD2030

• portable vibration analyzer performing spectral and statistical analysis on four channels simultaneously
• measures all parameters required by current regulations concerning workers protection from vibration related risks
• measure vibrations transmitted to both hand-arm and whole body
• satisfies the specifications of standards ISO 8041:2005, ISO 5349-1:2001 (handarm vibrations)
• ISO 2631-1, 2 and 4 1997 (whole-body vibrations)
• detects accelerations on four axes through two accelerometers with integrated amplifying electronics

 

CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR CU MASURA REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE TDS DELTA OHM HD2206.2

• Bench-top conductivity meter-Thermometer with back-lighted display,
• with inputs for measurements of conductivity, liquid resistivity, total dissolved solids (TDS) and the salinity by conductivity and temperature
• combined probes with 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger of conductivity or resistivity or TDS and temperature.
• RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time.