Mini-datalogger temperatura si umiditate relativa Delta Ohm HD206 HD226 HD207 HD227

Cod: Delta Ohm HD206 HD226 HD207 HD227


 

Brosura produs PDF, 0.73 Mb

Descriere

TEMPERATURE and RELATIVE HUMIDITY mini data logger with display, ON BOARD SENSORS MOUNTED OUTSIDE THE INSTRUMENT. Working range: temperature �30°C...+80°C, R.H. 5...98%. Resolution 0.1°C 0.1%R.H. Accuracy ±0.3°C (0...70°C), ±0.4°C outside ±2.5%R.H. Selectable storage interval 1-5-10-15-30 sec/min, 1 hour. Storage of 120,000 reading per channel, 8mm 3 ½ digit LCD display. IP54 protection degree.

 

Alte produse SENSECA

PH-METRU TERMOMETRU CU DATALOGGING DELTA OHM HD2105.1 HD2105.2

• pHmeter-Thermometer which measures pH, mV and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 34,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

SONOMETRU INTEGRATOR CLASA I SI CLASA II CU ANALIZA SPECTRALA SI STATISTICA DELTA OHM HD2010UC

• integrating portable sound level meter performing statistical analysis
• maximum low cost and simplicity of use
• possibility of adjusting the instrument and adding options at any time
• user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument
• Class 1 or 2 sound level meter according to IEC 61672-1 dated 2002, IEC 60651 and IEC 60804
• Assessment of the environmental noise level,
• Optional "data logging" function,
• Optional capture and analysis of sound events,
• Statistical analysis with the calculation of 3 percentile level and optional full statistical analysis

 

PIRANOMETRU CU FOTODIODA SILICONICA MASURA RADIATIE SOLARA GLOBALA PANOURI FOTOVOLTAICE DELTA OHM LP SILICON-PYRA04

• LP Silicon-PYRA 04. pyranometer
• measures the global solar radiation (W/m2) by using a silicon photodiode (400nm-1100nm).
• special geometry and the diffuser allow to have a pyranometer field of view of 180 degrees according to cosine law.
• The pyranometer is suitable for the measurement of natural sunlight.

 

TERMO-HIGROMETRU PORTABIL DELTA OHM HD2101.1 HD2101.2

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

TESTER MULTIPARAMETRU PH-METRU-CONDUCTIVIMETRU-TERMOMETRU DELTA OHM HD2156.1 HD2156.2

• pHmeter-Conductivity-Thermometer measures pH, mV, conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Datalogger, stores the maximum, minimum, average value and can store up to 20,000 sets of three measurements.
• USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

DATALOGGER HVACR VITEZA SI DEBIT AER, PRESIUNE, TEMPERATURA, UMIDITATE DELTA OHM DO2003

• HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes,
• Pt100 temperature probes for immersion, pointed and for surface,
• combined temperature/relative humidity probes.
• Pressure up to 2000 mbar and barometric pressure.
• Max-Min-Med, Rel measurements.
• Storage up to 12,000 readings.
• Serial output RS232C


CONDUCTIVIMETRU-TERMOMETRU MASURA CONDUCTIVITATE, REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE, SALINITATE, TEMPERATURA DELTA OHM HD2306.0

• Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

TESTER LABORATOR PARAMETRI ELECTROCHIMICI OXIGEN DIZOLVAT CONCENTRATIE INDEX SATURATIE DELTA OHM HD3409.2

• Bench-top Oxymeter-Thermometer measures dissolved oxygen,
• saturation index by polarographic type combined probes,
• temperature by Pt100 probes with SICRAM module.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

ANALIZOR VIBRATII 3-CANALE PROTECTIE VIBRATII MECANICE LA LOCUL DE MUNCA DELTA OHM HD2070

• portable vibration analyzer performing spectral and statistical analysis on three channels simultaneously
• measures all parameters required by current regulations concerning workers protection from vibration related risks
• measure vibrations transmitted to both hand-arm and whole body
• simplicity of use with maximum flexibility
• possibility of updating the instrument according to the evolution of the regulations relating to vibration measurement
• Octave and third octave filters, available as option (HD2070.O1), satisfy class 1 specifications of IEC 61260 standard

 

RADIOMETRU NET RADIATIE SOLARA ULTRAVIOLETA-INFRAROSU DELTA OHM LP NET07

• LP NET 07 measures the net radiation across a surface, from near ultraviolet to
• far infrared.
• The Net radiation is defined as the difference between the radiation that reaches the upper surface and the irradiation on the lower surface of the net radiometer.
• The surface of the upper receiver measures the direct solar radiation plus the diffuse one and the radiation at longer wavelengths emitted from the sky (clouds), while the lower receiving area measures the solar radiation reflected from the ground (albedo) and the radiation length wavelengths emitted from the earth.
• The instrument is designed and constructed to be used outdoors in any weather
• conditions.