Conductivimetru-Termometru masura conductivitate, rezistivitate lichide, solide dizolvate, salinitate, temperatura Delta Ohm HD2306.0

Cod: Delta Ohm HD2306.0


 

Brosura produs PDF, 0.44 Mb

Descriere

Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature.

Storage of maximum, minimum, average value.

Functions: REL, HOLD and auto power off which can be disabled,

IP 67 protection degree.

 

Complete with carrying case, instruction manual, 3 batteries. Conductivity probes, calibrating solutions and TP47... series temperature probes with SICRAM module have to be ordered separately.

 

 

Alte produse SENSECA

DATALOGGER MULTIFUNCTIONAL CU ANALIZA MICROCLIMA DELTA OHM HD32.1

• Globe temperature
• Natural wet bulb temperature
• Ambient temperature
• Atmospheric pressure
• Relative Humidity
• Air velocity
• Air temperature at the height of the head...

 

KIT CALIBRARE PH-METRE SI MV-METRE CU SIMULATOR DELTA OHM HD9609

• pH/mV simulator kit composed of instrument HD9609,
• adapter cables CP 9509/T,
• CP9509/BNC and
• carrying case.

 

PLUVIOMETRU MASURA CANTITATE SI DEBIT CADERI PRECIPITATII ATMOSFERICE PLOAIE DELTA OHM HD2013

• Rain gauge with tipping bucket,
• area 400cm2,
• for temperature range +4°C... +60°C.
• Standard resolution 0.2.
• On request at the time of placing the order resolution 0.1 or 0.5mm.
• Output contact normally closed.

 

DATALOGGER FOTO-RADIOMETRU LUMINA SOLARA, TEMPERATURA DELTA OHM DO9721

• Datalogger Photo-radiometer Thermometer which performs photometric, radiometric, PAR, temperature measurements.
• Two inputs.
• Function as datalogger: 30,000 samples, REL, Record, Q (integration),
• RS232C serial output

 

TERMOMETRU DIGITAL PORTABIL TERMOCUPLU K J T E DELTA OHM HD2328.0

• Thermocouple thermometer for probes type K, J, T, E
• Two inputs for miniature thermocouple connectors
• Storage of maximum, minimum, average valu
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

FOTO-RADIOMETRU PORTABIL CU DATALOGGER MASURA RADIATII OPTICE NECOERENTE CF DIRECTIVA EUROPEANA 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

DATALOGGER ANALIZOR MICRO-CLIMA WBGT DELTA OHM HD32.2 HD32.2A

• analysis of WBGT index (Wet Bulb Glob Temperature: wet bulb temperature and globe thermometer temperature) in presence or in absence of solar radiation
• Logging
• data transfer speed via the RS232 serial port
• The measurement unit of the temperature: °C, °F, °K
• Date and time of the instrument
• display of maximum, minimum, medium statistic parameters and their deletion

 

TERMO-HIGROMETRU PORTABIL DELTA OHM HD2101.1 HD2101.2

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

DATALOGGER PRESIUNE, TEMPERATURA, DEBIT DELTA OHM DO9704

• Datalogger for pressure, flow rate and temperature measurements with 2 inputs,
• memory 512 Kbytes,
• storage of maximum, minimum and average value.
• RS232 C output

 

ANEMOMETRU ULTRASONIC MASURA VITEZA SI DIRECTIE VANT TREI AXE DELTA OHM HD2003 HD2003.1

• Determination of the anemometric quantities represented in diverse measurement units:
• wind speed and direction,
• U-V-W Cartesian components of speed,
• sound speed,
• sonic temperature
• 5 analogue voltage or current outputs, with different measuring ranges.
• RS232 and Multidrop RS485 Serial Communication interfaces.