LP NET 07 measures the net radiation across a surface, from near ultraviolet to

far infrared. The Net radiation is defined as the difference between the radiation

that reaches the upper surface and the irradiation on the lower surface of the net

radiometer. The surface of the upper receiver measures the direct solar radiation

plus the diffuse one and the radiation at longer wavelengths emitted from

the sky (clouds), while the lower receiving area measures the solar radiation

reflected from the ground (albedo) and the radiation length wavelengths emitted

from the earth.

The instrument is designed and constructed to be used outdoors in any weather

conditions.

 

Alte produse SENSECA

ANEMOMETRU-TERMOMETRU DIGITAL DELTA OHM HD2103.1 HD2103.2

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.
• RS232C/USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP67 protection degree.

 

LUXMETRU MASURA ILUMINANTA, PAR, IRADIANTA LUMINA SOLARA DELTA OHM HD2302.0 HD2302.0VP474

• Device for measuring illuminance, luminance, PAR, irradiance
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

TESTER LABORATOR PARAMETRI ELECTROCHIMIE: PH, CONDUCTIVITATE, OXIGEN DIZOLVAT, REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE, CONCENTRATIE DELTA OHM HD22569.2

• bench top instrument for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature.
• It is are fitted with a large backlighted LCD display.
• pH, mV, redox potential (ORP) with pH, redox electrodes or electrodes with separate reference;
• conductivity, resistivity in liquids,
• total dissolved solids (TDS) and salinity with combined 4-ring and 2-ring conductivity/
• temperature probes with direct input or SICRAM module;
• concentration of dissolved oxygen in liquids (in mg/l) and saturation index (in %),

 

LUXMETRU FOTO-RADIOMETRU MASURA ILUMINANTA, PAR, IRADIANTA SOLARA DELTA OHM HD2102.1 HD2102.2

• Device for measuring illuminance, luminance, PAR, irradiance.
• Storage of maximum, minimum, average value and the integral Q(t),
• RS232 C output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

TURBIDIMETRU PORTABIL DE LABORATOR TESTARE LICHIDE PROCES, APA POTABILA, APE UZATE DELTA OHM HD25.2

• Portable and bench turbidity meter equipped with 3 photodetectors and two light sources
• it measures according to the standard EPA 180.1, ISO-NEPH (ISO 7027), EBC and ASBC.
• Automatic calibration,
• datalogger,
• data downloading to PC by RS232C or USB 2.0 through the software DeltaLog11

 

TESTER OXIGEN DIZOLVAT SI TERMOMETRU CU DATALOGGING DELTA OHM HD2109.1 HD2109.2

• Oxygen meter-Thermometer measures dissolved oxygen, saturation index and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 18,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

FOTO-RADIOMETRU PORTABIL CU DATALOGGER MASURA RADIATII OPTICE NECOERENTE CF DIRECTIVA EUROPEANA 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

CONDUCTIVIMETRU-TERMOMETRU DE LABORATOR CU MASURA REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE TDS DELTA OHM HD3406.2

• Bench-top Conductivity meter-Thermometer measures conductivity, liquid resistivity,
• total dissolved solids (TDS) and salinity by 2 or 4 electrodes,
• combined conductivity probes and temperature by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value, it can store up to 36,000 samples.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled.,
• protection degree IP 66

 

TERMOMETRU DIGITAL PORTABIL TERMOCUPLU K, J, T, R, N, S, B, E DELTA OHM HD2108.1 HD2108.2 HD2128.1 HD2128.2

• Thermocouple thermometer with one input and logger 32.000 samples
• For K, J, T, R, N, S, B, E type probes with miniature connector
• Storage of maximum, minimum, average value,
• USB/RS232 C connection to download loggerdata to PC.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

DATALOGGER 8-16 CANALE INREGISTRARE TEMPERATURA DELTA OHM HD32.7 HD32.8.8 HD32.8.16

• HD32.7 - 8 INPUTS DATA LOGGER FOR pt100 SENSOR PROBES
• HD32.8.8/ HD32.8.16 Rugged data logger with 8/16 inputs for K, J, T, N, R, S, B and E type thermocouple with miniature connector temperature probes
• Unit of measurement °C, °F, °K configurable.
• Data logging: instantaneous or postponed, with the possibility of selecting the storage start and end.
• Data download: RS232C, 1200...38400 baud or USB 1.1 - 2.0.
• DeltaLog9 software for data download and processing.