Sonometru integrator Clasa I si Clasa II cu analiza spectrala si statistica Delta Ohm HD2010UC

Cod: Delta Ohm HD2010UC


 

Brosura produs PDF, 0.37 Mb
             

Descriere

HD2010UC kit1 is an integrating portable sound level meter performing statistical analysis.

The instrument has been designed combining maximum low cost and simplicity of use. Attention has been paid to the possibility of adjusting the instrument and adding options at any time to the HD2010UC so to extend its applications. The user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument.

 

Technical regulations:
• Class 1 sound level meter according to IEC 61672-1 dated 2002 (Certificate of Compliance I.N.RI.M. n. 07-0124-02), IEC 60651 and IEC 60804.

 

 

Applications:
• Assessment of the environmental noise level,
• Optional "data logging" function,
• Optional capture and analysis of sound events,
• Statistical analysis with the calculation of 3 percentile level and optional full statistical analysis,
• Identification of impulsive noises,
• Measurements in workplaces,
• Selection of personal protective equipments (SNR and HML methods),
• Production quality control,
• Measurement of machine noise.

Sound level meter class 1 or 2 Kit
• HD2010UC kit1 and kit2: consists of HD2010UC sound level meter class 1, HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2), windscreen, 5m extension cable and serial RS232 or USB connection cable. Noise Studio PC programme.
• HD2010UC kit1/E: version for outdoor measurements, it consists of HD2010UC sound level meter class 1, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme
• HD2010UC kit1/IE: version for indoor and outdoor measurements, It consists of HD2110 Sound Level Meter, HD WME weatherproof microphone unit, HD2110PWheated preamplifier, preamplifier HD2110P, MK223 microphone cartridge for free field, windscreen HD SAV, 5m extension cable CPA/5 and RS232 serial or USB connection cable. Noise Studio PC program.

Calibration of soundlevel meters: Delta Ohm can carry out all calibrations according to international recognized standards.

 

Calibrator class 1 for this instrument: HD2020

 

These kits are also available as class 2 soundlevel measurement: HD2010UC Class 2

 

 

 

 

HD2010UC kit 2 is an integrating portable sound level meter performing statistical analysis.

The instrument has been designed combining maximum low cost and simplicity of use. Attention has been paid to the possibility of adjusting the instrument and adding options at any time to the HD2010UC so to extend its applications. The user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument.

 

Technical regulations:
• Class 2 sound level meter according to IEC 61672-1 dated 2002 (Certificate of Compliance I.N.RI.M. n. 07-0124-02), IEC 60651 and IEC 60804.

 

Applications:
• Assessment of the environmental noise level,
• Optional "data logging" function,
• Optional capture and analysis of sound events,
• Statistical analysis with the calculation of 3 percentile level and optional full statistical analysis,
• Identification of impulsive noises,
• Measurements in workplaces,
• Selection of personal protective equipments (SNR and HML methods),
• Production quality control,
• Measurement of machine noise.

 

Sound level meter class 2

• HD2010UC kit 2: consists of HD2010UC sound level meter class 2, HD2010PNE2 preamplifier, UC52/1 microphone for free field, windscreen, 5m extension cable and serial RS232 or USB connection cable. Noise Studio PC programme.

 

Accesorii standard

 

 

Alte produse SENSECA

SONDA RADIOMETRICA EXTERIOR MASURA IRADIANTA LUMINA SOLARA DELTA OHM LP UVA02

• Radiometric probe for outdoor use for measuring IRRADIANCE in the range UVA (315...400nm).
• mV per mW/cm2 output.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors

 

ALBEDOMETRU PIRANOMETRU MASURA ALBEDOU SI RADIATIE GLOBALA INCIDENTA DELTA OHM LPPYRA05

• Albedometer First and Second Class pyranometers according to ISO 9060.
• Complete with: upper and bottom shade disk, desiccant sachet with silica-gel crystals, 2 cartridges, levelling device, support bracket
• calibration report.
• On request 5 or 10m cables with connectors.

 

ANEMOMETRU-TERMOMETRU DIGITAL DELTA OHM HD2103.1 HD2103.2

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.
• RS232C/USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP67 protection degree.

 

DATALOGGER METEO CU ACHIZITIE SI INREGISTRARE DATE DELTA OHM HD32MT.1

• 16-channel data logger capable of capturing and logging the values measured by a series of sensors connected to its inputs
• Sensors with analog voltage output, both unipolar and bipolar
• Sensors with analog current output(0..20mA, 4..20mA)
• Temperature sensors thermocouple(typpe K, J, T, N, R, S, B, E)
• Pt100/Pt1000 and NTC temperature sensors
• Sensors with digital output TTL level pulse (ON/OFF)
• Sensors with open/close contact output(e.g. rain gauges, cup anemometers

 

DATALOGGER MULTIFUNCTIONAL 3 CANALE INREGISTRARE PARAMETRI CALITATE MEDIU AER DELTA OHM DO9847

• Multifunctional handheld board instrument and datalogger
• RH, temperature, pressure, airspeed, light, voltage, current
• 128x64 pixel (56x38 mm) graphic display and three independent inputs
• Functions: watch, hold, max., min., average, record, immediate or deferred start record logging, difference between the two inputs, relative measures
• Storage capacity: 32.000 readings per input.
• RS232C serial output: from 300 up to 115.200 baud rate.

 

LUXMETRU FOTO-RADIOMETRU MASURA ILUMINANTA, PAR, IRADIANTA SOLARA DELTA OHM HD2102.1 HD2102.2

• Device for measuring illuminance, luminance, PAR, irradiance.
• Storage of maximum, minimum, average value and the integral Q(t),
• RS232 C output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

FOTO-RADIOMETRU PORTABIL CU DATALOGGER MASURA RADIATII OPTICE NECOERENTE CF DIRECTIVA EUROPEANA 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

PIRANOMETRU CLASA A 2A IN CONFORMITATE CU STANDARDUL ISO9060 DELTA OHM LP PYRA08

• Second class pyranometer according to ISO 9060,
• fast response sensor complete with calibration report,
• possibility to replace the exhausted silica-gel.
• Different configurations available.
• Male M12 connector.
• On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.

 

TESTER LABORATOR PARAMETRI ELECTROCHIMIE: PH, CONDUCTIVITATE, OXIGEN DIZOLVAT, REZISTIVITATE LICHIDE, SOLIDE DIZOLVATE, CONCENTRATIE DELTA OHM HD22569.2

• bench top instrument for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature.
• It is are fitted with a large backlighted LCD display.
• pH, mV, redox potential (ORP) with pH, redox electrodes or electrodes with separate reference;
• conductivity, resistivity in liquids,
• total dissolved solids (TDS) and salinity with combined 4-ring and 2-ring conductivity/
• temperature probes with direct input or SICRAM module;
• concentration of dissolved oxygen in liquids (in mg/l) and saturation index (in %),

 

MANOMETRU-TERMOMETRU DIGITAL PORTABIL DELTA OHM HD2124.1 HD2124.2

• Manometer-Thermometer with two inputs for SICRAM module PP471 to connect probes TP704 and TP705 series.
• Temperature measurement with Pt100 probe complete with SICRAM module measuring range 200°C +650°C.
• Datalogger which stores the maximum, minimum, average value and can store up to 32,000 couples of samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD, PEAK and auto power off which can be disabled,
• IP 67 protection degree.