Cod: Megger TDR2000/3 1003-036 TDR2000/3P 1003-037
Descriere
TDR2000/3 is a highly portable, high resolution, compact, dual channel time domain reflectometer with a large colour screen for locating faults on paired metallic cables in applications as diverse as street lighting, telephony and CATV
With a best resolution of 0.1m the TDR2000/2 has a 20km maximum range depending on the velocity factor selected and the cable type. Five output impedances are available (25, 50, 75, 100 and 125 ohms) and with an auto impedance matching feature and a velocity factor between 0.2 and 0.99 to meet any cable test requirements.
Powered by Li-ion rechargeable batteries, it is available in two configurations.
TDR2000/3 - high resolution TDR with backlit colour display and powered by Li-ion rechargeable battery batteries, complete with 2 pairs of mini-clip test leads.
TDR2000/3P - high resolution TDR with backlit colour display and powered by Li-ion rechargeable battery batteries, complete with 2 pairs of fused test leads.
Accesorii standard
TDR2000/3 Time Domain Reflectometer 1003-036
TDR2000/3P Time Domain Reflectometer 1003-037
Download Kit 1003-353
Terminal Adaptor Kit 1003-218
Included Accessories
Carry Case 1003-217
Dual Fused test leads (TDR2000/3P) 1002-136
User Guide CD 2003-074
Dual mini-clamp test leads (TDR2000/3) 6231-654
Carry Case 1003-217
Optional accessories
AC-DC Charger 1003-352
Pair mini-clamp test leads 6231-652
Replacement Battery 1002-552
Pair Fused test leads 1002-015
Alte produse MEGGER
|
DC CIRCUIT BREAKER TESTER MEGGER ½ CB360
• Capable of testing electromechanical or thermal-magnetic trip devices with dc current
|
|
MICROOHMMETRU PORTABIL 300A MEGGER MOM3
• Capacitate mare de curent
|
|
TRUSA TESTARE RIGIDITATE ULEI ELECTROIZOLANT MEGGER OTS60PB OTS80PB
• portable 60 kV and 80 kV oil test sets |
|
MEGGER - B10E
• Reliable and stable a.c. and d.c. power supply for circuit breaker testing
|
|
PRIMARY CURRENT INJECTION TEST SYSTEM MEGGER ODEN AT
• Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
|
|
PUNTE PENTRU MASURAT TANGENTA UNGHIULUI DE PIERDERI DIELECTRICE MEGGER DELTA4000
• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set |
|
PRIMARY CURRENT INJECTION TEST SYSTEM MEGGER INGVAR
• Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
|
|
ANALIZOR DIAGNOZA IZOLATIE SI PIERDERI ULEI ELECTROIZOLANT MEGGER IDAX-300 IDAX-350
• Automated measurement and analysis of moisture content, tan delta/power factor and oil conductivity |
|
MULTI-AMP CIRCUIT BREAKER TESTER RETROFIT MEGGER DDA16, DDA30 AND DDA60
• Drop-in retrofit capability to the Multi-Amp Model CB-9116, Model DB-8130 and Model CB-8160 circuit breaker test sets
|
|
TESTER IZOLATIE SI CONTINUITATE MEGGER MIT200 MIT210 MIT220 MIT230
• Testoare de izolaţie şi continuitate de buzunar - MIT210, MIT220, MIT230
|