Descriere

  • 15ppm/year Accuracy
    DC/AC voltage up to 1000 V
  • DC/AC current up to 30 A
  • Resistance up to 1000 MO, capacitance up to 100 uF
  • TC/RTD temperature sensors simulation
  • Frequency output up to 20 MHz
  • Electric power up to 240 V / 20 A
  • Built-in process multimeter
  • GPIB & RS232 interface

 

Description

Multifunction calibrator M142 is calibrator of electric quantities for application in calibration laboratories and in production lines where meters are manufatured. It can be used for calibration and adjustment of meters from the field of voltage, current, resistance, capacity and frequency. Installed harmonic and non-harmonic shape signals as well make it possible to test parameters of the meters by a signal with various crest factor. Frequency modes enable to set frequency, amplitude and duty ratio of the output signal. They are suitable for basic calibration of oscilloscopes. The calibrator is equipped with possibility to measure temperature with TC and RTD temperature sensors. Built-in multimeter can be used independently or in simultaneous operation with source part of the calibrator together. Testing of transducers of various types, regulators and evaluating units can be perform with it without necessity to use any other measuring instrument.

M140 multifunction calibrator is available in bench-top and in 19" rack housings.

 
Basic parameters

Basic function of the calibrator is generating of the calibrated DC/AC voltage in the range from 0 V to 1000 V and DC/AC current in the range from 0 A to 30 A . Using a 50-turn coil the current range can be extended to 1500 A. The best accuracy of the calibrator on DC voltage ranges is 15 ppm, on AC voltage ranges 250 ppm, on DC current ranges 130 ppm and on AC current ranges 550 ppm. Maximum frequency range is from 20 Hz to 100 kHz for harmonic output waveform. The calibrator is equipped with the function of generation the periodic non-harmonic signals with the defined crest factor. Thus it makes possible to test sensitivity of multimeters to distorted signals. Next function of the calibrator is simulation of resistance and capacity. With the calibrator, the resistance in range from 0 O to 1000 MO and capacitance from 1 nF to 100 µF can be simulated with the enough precision for calibration of common used hand-held multimeters. Basic accuracy of the resistance ranges is 150 ppm%, of the capacitance ranges it is 0.1 %.

Frequency function of the calibrator makes it possible to generate a square wave signal with adjustable and calibrated duty ratio, frequency and amplitude in range from 1 mV to 10 V in the frequency band up to 10 kHz. In the mode HF the square wave signal up to 20 MHz with a very low risetime can be generated. The frequency functions are suitable for the calibrations of corresponding frequency ranges of the multimeters, and for calibration of the channel sensitivities and time bases of the oscilloscopes as well.

For calibrations of DC and one-phase AC power-meters and energy meters, the power - energy mode is determined. Output voltage can be set up to 240 V and output current up to 20 A with the power factor in range from -1 to +1 in the frequency band from 40 Hz to 400 Hz. Current capability of the voltage output is 30 mA. It allows to calibrate also analogue power-meters which has usually higher consumption. For calibrations of the thermometers and temperature regulators, the function of simulation of temperature sensors is determined. Calibrator is able to simulate all common used Pt and Ni resistance sensors and TC sensors of the R, S, B, J, T, E, K and N types as well. Compensation of the TC cold junction is made either by entering value from the keyboard, or automatically by measuring the ambient temperature with Pt-100 sensor. The precision of the simulated resistance and TC sensors depends on set value and type of the sensor. For resistance sensors uncertainty band is in the range from 0.04°C to 0.5°C, for TC sensors from 0.4°C to 4.0°C.

 

Built-in multimeter

Internal multimeter with basic capability to measure DC current to 20 mA, DC voltage to 10 V, resistance to 2 kO and frequency to 15 kHz is standard part of the calibrator. With accuracy of 100 ppm it enables to measure output signals of various types of transducers. With external TC or resistance temperature sensor temperature can be scan and similarly, with external strange gauge sensorspressure, torsion, strength, etc. can be measured and displayed.

 

Calibrator - Tester

Calibrator can be used in simultaneous mode, i.e. selected output signal is generated and the response of the device under test is measured at the same time by internal multimeter. Programmable capability of the calibrator enables setting of 10 steps defined by output signal function and output value on source side and awaiting response of DUT measured by internal multimeter including allowed limits of the DUT. The testing can run automatically.

 

User confort

M142 Calibrator is equipped with a number of other functions which make its use easier. Among them belong possibility to set relative deviations from the actual value of the selected output signal, displaying of the output signal uncertainty, internal calibration procedure and others. Concept of the calibrator's control and indication uses a large area luminescence display on which all necessary information is concentrated. The control is perform by selection from the menu. Moreover, frequently used functions have firmly assigned keys with direct control. Normally, the calibrator is equipped with the GPIB bus and with the RS-232 serial port making it possible to be controlled by personal computer.

The calibrator can be included into MEATEST WinQbase/CALIBER software calibration systems.

M142 calibrator is derived from previous successful model M140. Against M140 model the M142 new one offers extended ranges and higher accuracy.

 

 

Accesorii standard

  • Power line cable  1 pc 
  • Operation manual, CD  1 pc 
  • Option 10/11  Test lead 1000V - 20 A, black/red 2 pcs Length 1m
  • Option 40, 60, 70, 80  1 pc Length 1m
  • Spare fuse  1 pc 
  • RS 232 cable  1 pc Length 1m
 

Optiuni recomandate

  • Option 140-50 Current coil 25/50 turns For clamp ammeters calibration
  • Option 10 Test lead 20A/1000V (cerný) Length 1m
  • Option 11 Test lead 20A/1000V (cervený) Length 1m
  • Option 20 Test cable BNC - BNC Length 1m
  • Option 30 Test cable BNC - banana Length 1m
  • Option 40 Cable adapter Canon 25 / 2 x banana For DC voltage/current
  • Option 60 Cable adapter Canon 25 / 4 x banana Four wire resistance measurement
  • Option 70 Four wire cable adapter Four wire resistance simulation
  • Option 80 Cable adapter Cannon 25 / 2 x banana mVDC and TC measurement
  • Option 90 External sensor RTD temperature sensor
  • Option 140-01 Cable adapter with metal pad for test unit

Contains Pt100 sensor for ambient temperature measurement and cold junction

compensation.
 
  • Cable GPIB  GPIB cable   Length 1m
  • Cable RS-232 RS-232 cable  Length 1m
  • WinQbase Database software for meter calibration
  • CALIBER Software for automatic calibration of meter
 

Alte produse MEATEST

DECADA REZISTIVA 10KV CALIBRARE MEGOHMMETRE SI TESTERE IZOLATIE MEATEST M191

• Total resistance range 10.00 k? to 1000.0 G?
• Resistance accuracy 0.1 to 5 %
• Test voltage range 10 000 VDC + 5%
• Test voltage accuracy indication 0.5 % + 10 V
• Test current indication 4 digit from 0.01 pA to 99.99 mADC
• Programmable high resistance decade box
• Short current verification
• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)
• High voltage capacitance in three fix points 10, 50, 100 nF
• HIPOT timer verification

 

CALIBRATOR UNIVERSAL INALTA PRECIZIE MEATEST M142I

• 15ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 30 A
• TC temperature sensors simulation
• RS232 interface

 

CALIBRATOR UNIVERSAL MULTIFUNCTIONAL DE LABORATOR SI PRECIZIE MEATEST M143

• Wide voltage range from 0 to 1000 V DC/AC with accuracy 0.01 %
• Extended current range from 0 to 20 A DC/AC with accuracy 0.02 %
• Extended current range to 1000 A for calibration of clamp ammeters
• Sinusoidal & Non-sinusoidal waveforms
• Fix standard resistors 10 O to 100 MO in decimal values with calibration accuracy 0.02 %
• Thermocouple temperature sensor simulation R, S, B, J, T, E, K, N in range from 250 °C to 1850 °C
• Cold junction automatic compensation using external Pt1000 sensor
• RTD temperature sensor simulator as option

 

REZISTENTA CAPACITATE INDUCTANTA STANDARD PENTRU CALIBRARE RLC-METRE

• Resistance Capacitance Inductance standards
• Traceability of electric quantities
• Calibration of meters
• Calibration uncertainty 0.005 %
• Low time constant
• Three/four terminal or four pair terminal connection

 

CALIBRATOR IMPEDANTA RLC-METRE: REZISTENTA, CAPACITATE, INDUCTANTA MEATEST M550

• Resistance standards from 0.1 O to 100 MO
• Capacitance standards from 10 pF to 100 µF
• Simulated inductance standards from 10 µH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard

 

CALIBRATOR MULTIFUNCTIONAL UNIVERSAL MEATEST M141

• 100ppm Accuracy
• DC/AC voltage up to 750 V
• DC/AC current up to 2 A
• Fix standard resistors from 10 O to 10 MO in decade values
• TC temperature sensors simulation
• Frequency output up to 20 MHz
• RS232 & GPIB (option) interface

 

CALIBRATOR DE LABORATOR TENSIUNE, CURENT, REZISTENTA, CAPACITATE, FRECVENTA MEATEST M140

• 35ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 20 A
• Resistance up to 50 MO, capacitance up to 50 µF
• TC/RTD temperature sensors simulation
• Frequency output up to 20 MHz
• Electric power up to 240 V / 10 A
• Built-in process multimeter
• GPIB & RS232 interface

 

REZISTOR ETALON DE PRECIZIE SI FRECVENTA INALTA CALIBRARE RLC-METRE MEATEST M530

• Resistance range 10 O to 1000 O
• Very low frequency dependency
• Applicable frequency range to 100 MHz
• Calibration of wide frequency range LCR meters

 

CALIBRATOR PUTERE SI ENERGIE ACTIVA, REACTIVA, APARENTA, FAZA, UNGHI MEATEST M133I

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 30 mA to 30 A / 5 V, accuracy 310 ppm
• Power factor setting -1 to +1
• Frequency range 15 Hz to 1 kHz
• Simulated electric power up to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

DECADA CAPACITIVA CALIBRARE RLC-METRE MEATEST M520

• Designed for RCL meters calibration
• Range of capacitance from 100 pF to 12 mF
• Basic accuracy 0.25 %
• Maximal operating voltage 50 V
• Power supplying from internal battery or power line adapter