Filtru putere aplicatii Tempest/ EMP de mare performanta curenti 16..200A ETS-Lindgren N600X

Cod: ETS-Lindgren N600X


 

Brosura produs PDF, 0.64 Mb

Descriere

  • Suitable for 400Hz supplies
  • Compact Rugged Construction
  • Maximum Protection for EMP and Tempest applications
  • Current Range 16 to 200 Amperes
  • 100 dB Insertion Loss from 14 kHz to 40 GHz
  • Low power dissipation

 

APPLICATIONS

  • In high performance screened rooms and anechoic chambers the N600X series provides protection of both incoming and outgoing supplies in line with the shield performance.
  • In TEMPEST applications, the N600X filters provide an extremely high degree of protection required to obtain maximum security.
  • N600X filters are ideal for EMP applications needing to meet the most stringent NATO requirements.
  • N600X filters can be used for filtering of mains incomers entering screened room facilities.

 

Electrical Specifications

PART #

Current Max (Amps)

Voltage Max (Volts)

Frequency (Hz)

Number of Lines

Volt Drop on Full Load in a 250V 50/60 Hz System Per Line (Max)

Full Load Dissipation (W)

6000

16

250

DC/50/60/400

2

1.2

35

6001

16

440/250

DC/50/60/400

4

1

45

6002

32

250

DC/50/60/400

2

1.1

70

6003

32

440/250

DC/50/60/400

4

0.75

50

6004

63

250

DC/50/60/400

2

1.3

68

6005

63

440/250

DC/50/60/400

4

0.75

155

6006

100

250

DC/50/60/400

2

0.7

135

6007

100

440/250

DC/50/60/400

4

0.5

135

6009

200

440/250

DC/50/60/400

4

1

400

 

Alte produse ETS-LINDGREN

TESTER CAMP MAGNETIC 2..400 KHZ ETS-LINDGREN HI-3637

• 0.06 mG - 400 G (with 100X probe)
• 2 - 400 kHz
• True RMS Detection
• Three concentric orthogonal field sensors

 

ANTENA DE BANDA LARGA BICONICA 30 MHZ..1 GHZ ETS-LINDGREN 3180

• Frequency Maximum 1 GHz
• Connectors Type N (F)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W

 

TESTER CURENT RF INDUS 9 KHZ..70 MHZ ETS-LINDGREN HI-3702

• Wide Frequency Response (9 kHz - 70 MHz)
• Eliminates concern over foot contact and body orientation
• Monitors induced current while standing, walking, or climbing.
• Thermally based True RMS Converter Circuit for increased accuracy

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5402

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA HORN PIRAMIDAL MULTI-OCTAVA LINIAR POLARIZATA 960 MHZ..40 GHZ ETS-LINDGREN 3160

• Frequency Minimum 960 MHz
• Frequency Maximum 40 GHz
• Pattern Type directional
• Polarization linear

 

TESTER MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE MONITOARE VIDEO SI TERMINALE CU DISPLAY ETS-LINDGREN HI-3603

• VDT / VLF Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings

 

ANTENA LOG-PERIODICA DIRECTIONALA MASURATORI CISPR 16-1 BANDA 200 MHZ..2 GHZ ETS-LINDGREN 3148B

• Frequency Minimum 200 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1 kW
• Pattern Type directional
• Peak Power 1.3 kW
• Polarization linear

 

ANTENA SPIRALA CONICA LOGARITMICA 200 MHZ..1 GHZ ETS-LINDGREN 3101

• Frequency Minimum 200 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 100 W
• Pattern Type directional
• Peak Power 150 W
• Polarization circular
• VSWR 2.4:1
• Extremely low VSWR
• Individually calibrated

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA HORN GHID MICROUNDE DUBLU CREASTA 750 MHZ..18 GHZ ETS-LINDGREN 3115

• Frequency Minimum 750 MHz
• Frequency Maximum 18 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 500 W
• Pattern Type directional
• Polarization linear