Tester masura radiatii camp electromagnetic emise de monitoare video si terminale cu display ETS-Lindgren HI-3603

Cod: ETS-Lindgren HI-3603


 

Brosura produs PDF, 0.19 Mb

Descriere

  • VDT / VLF Survey Instrument
  • Wide Dynamic Range
  • On-Board Data Logging
  • Combination E & H Readings

 

Electrical Specifications

Data Logging

127 data points using front panel controls

Frequency Response, Electric Fields

2 kHz - 300 kHz, ± 2 dB

Frequency Response, Magnetic Fields

8 kHz - 300 kHz, ± 2 dB

Magnetic Field Units

User Selectable (amperes/meter, gauss, tesla)

Power Supply

2 - 9 volt batteries

Sensitivity, Electric Field

1 - 2000 Volts/meter in three ranges

Sensitivity, Magnetic Field

1 - 2000 Milliamperes/meter in three ranges

 

Accesorii standard

  • Tripod Mounting Socket
  • User Manual
  • Dielectric Handle
  • Custom Carrying Case
 

Optiuni recomandate

  • 491008 Dielectric Floor stand
  • 4413 Serial Interface
  • 491009 Dielectric Tripod
  • HI-3616 Remote Control Readout
  • Dielectric Spacer (30 cm) for VDT measurements
  • Plastic Fiber Optic Cable
 

Alte produse ETS-LINDGREN

FILTRE PROTECTIE TEMPEST/RFI/ EMI PETRU LINII TRANSMISII DATE ANALOGICE/ DIGITALE ETS-LINDGREN N2460

• Suitable for EMI and Tempest Protection
• Digital and analogue transmissions
• Tubular, flat-pack or modular design

 

CAMERA ECRANATA ACUSTIC TESTARE DISPOZITIVE DIMENSIUNI MICI ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

TESTER CAMP MAGNETIC 5..2000 HZ ETS-LINDGREN HI-3627

• 5 - 2000 Hz
• 0.2 mG - 20 G
• Three Concentric Orthogonal Field Sensors
• True RMS Detection
• Isotropic Response
• 100dB Dynamic Range

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5402

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

FILTRU PUTERE APLICATII TEMPEST/ EMP DE MARE PERFORMANTA CURENTI 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

TESTER MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE LINII TRANSMISIE RETELE ENERGIE ELECTRICA ETS-LINDGREN HI-3604

• Power Line Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings

 

ANTENA LOG-PERIODICA DIRECTIONALA MASURATORI CISPR 16-1 BANDA 200 MHZ..2 GHZ ETS-LINDGREN 3148B

• Frequency Minimum 200 MHz
• Frequency Maximum 2 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1 kW
• Pattern Type directional
• Peak Power 1.3 kW
• Polarization linear

 


CAMERA ECRANATA TESTARE EMI/RFI ETS-LINDGREN 5240

• Ease of operation in a compact, portable format
• Maximum performance Double Electrically Isolated (DEI) RF door with toggle action over center draw latches
• High performance 24 ounce copper shielding construction
• Shielding performance of 120 dB+

 

ANTENA BUCLA MAGNETICA ECRANATA FRECVENTA JOASA 20 HZ..500 KHZ ETS-LINDGREN 7604

• Frequency Minimum 20 Hz
• Frequency Maximum 500 kHz
• Connectors Type BNC
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear