Celula GTEM test, masura, incercari emisii electromagnetice si imunitate EMC ETS-Lindgren 5402

Cod: ETS-Lindgren 5402


 

Brosura produs PDF, 0.12 Mb

Descriere

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f < 1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

50 W

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq < 1.50:1
Characteristic Freq < 1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Accesorii standard

  • Manual emissions correlation software (on request)
  • 7/16" DIN to type "N" adaptor
  • Individually characterized with results of TDR and VSWR tests
  • 5400 GTEM! Series manual
  • One removable access port in floor
  • ETS-Lindgren absorber material
  • Primary door 6.3" W x 9.1" H clear opening (16 cm x 23 cm)
  • Completely assembled
 

Optiuni recomandate

  • Blank connector panel
 

Alte produse ETS-LINDGREN

ANTENA HORN GHID MICROUNDE DUBLU CREASTA 750 MHZ..18 GHZ ETS-LINDGREN 3115

• Frequency Minimum 750 MHz
• Frequency Maximum 18 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 500 W
• Pattern Type directional
• Polarization linear

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA LOG-PERIODICA POLARITATE LINIARA 100 MHZ..1 GHZ ETS-LINDGREN 3150

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors 7/8 EIA Flange (others available)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type directional
• Polarization linear

 

ANTENA SPIRALA CONICA LOGARITMICA 100 MHZ..1 GHZ ETS-LINDGREN 3103

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 100 W
• Pattern Type directional
• Peak Power 100 W
• Polarization circular
• VSWR 1.6:1
• Two Year Warranty
• Extremely low VSWR

 

ANTENA HORN PIRAMIDAL CU GENERARE CAMP ELECTRIC TESTARE EMC AUTO GMW 3097 SI ES-XW7T-1A278-AC 1.2..1.4 GHZ ETS-LINDGREN 3162-01

• Frequency Minimum 1.2 GHz
• Frequency Maximum 1.4 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 550 W
• Pattern Type directional
• GMW 3097
• ES-XW7T-1A278-AC

 

ANTENA HORN DESCHISA CUADRI-CREASTA 300 MHZ..6 GHZ ETS-LINDGREN 3164-06

• Frequency Minimum 300 MHz
• Frequency Maximum 6 GHz
• Connectors SMA Female (2)
• Cross Polarization Isolation >25 dB
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W
• Linear or Circular Polarization (With Hybrid)

 

ANTENA DE BANDA LARGA OMNIDIRECTIONALA 1..18 GHZ ETS-LINDGREN 3183

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• VSWR Ratio (AVG) 2:1
• Maximum Continuous Power 50 watts @ 1GHz, 25 watts @ 18 GHz
• Chamber Characterization
• Broadband Spectrum Monitoring

 

ANTENA MONOPOL PASIV DE TRANSMISIE CAMP ELECTRIC 1 KHZ..30 MHZ ETS-LINDGREN 3303

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Peak Power 1 W
• Polarization linear
• Switchable Two-band Transformer
• Two Year Warranty

 

ANTENA HIBRID LOG-PERIODICA DE BANDA LARGA PENTRU MASURATORI EMC 26 MHZ..3 GHZ ETS-LINDGREN 3140B

• Frequency Minimum 26 MHz
• Frequency Maximum 3 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1 kW
• Pattern Type directional
• Peak Power 1.3 kW
• Polarization linear
• Best EMC RI Performance

 

TESTER MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE CUPTOARE MICROUNDE ETS-LINDGREN HI-1501

• Three Ranges
• Calibrated at 2450 MHz
• Battery Operated
• Extra sensitivity for Compliance Measurement