Celula GTEM test, masura, incercari emisii electromagnetice si imunitate EMC ETS-Lindgren 5402

Cod: ETS-Lindgren 5402


 

Brosura produs PDF, 0.12 Mb

Descriere

  • Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
  • Post Production
  • For all Phases of EMC Testing - Design Qualification - Pre-Compliance
  • Full Compliance IEC 61000-4-3 ANSI C63.4

 

Electrical Specifications

Feed Connector Type

cw 7/16 DIN to N Adapter

Field Uniformity

f < 1 GHz, 0 -6dB

Frequency

9 kHz - 5 GHz (RE) 1
DC - 20 GHz (RI) 2

Input Impedance

50 ?

Maximum CW Input

50 W

Shielding Effectiveness

10 kHz - 1 GHz
From Internal E-Fields 80 dB min

VSWR Maximum

All Other Freq < 1.50:1
Characteristic Freq < 1.75:1

VSWR Typical

All Other Freq 1.30:1
Characteristic Freq3 1.75:1

 

Accesorii standard

  • Manual emissions correlation software (on request)
  • 7/16" DIN to type "N" adaptor
  • Individually characterized with results of TDR and VSWR tests
  • 5400 GTEM! Series manual
  • One removable access port in floor
  • ETS-Lindgren absorber material
  • Primary door 6.3" W x 9.1" H clear opening (16 cm x 23 cm)
  • Completely assembled
 

Optiuni recomandate

  • Blank connector panel
 

Alte produse ETS-LINDGREN

ANTENA BUCLA PASIVA TESTARE ECRANARE SI IMUNITATE RADIATII 1 KHZ..30 MHZ ETS-LINDGREN 6509

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Input Power 1 kW
• Pattern Type omnidirectional
• Polarization linear

 

CAMERA ECRANATA ACUSTIC TESTARE DISPOZITIVE DIMENSIUNI MICI ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

MATERIALE ABSORBTIE RADIATII EMC SI MICROUNDE ETS-LINDGREN

• EMC Anechoic Absorber
• Ferrite Tile Absorber
• FerroSorb FS EMC Absorber
• FerroSorb PS EMC Absorber
• Ultra Broadband Microwave Absorber

 

ANTENA HORN PIRAMIDAL MULTI-OCTAVA LINIAR POLARIZATA 960 MHZ..40 GHZ ETS-LINDGREN 3160

• Frequency Minimum 960 MHz
• Frequency Maximum 40 GHz
• Pattern Type directional
• Polarization linear

 

ANTENA BICONICA MASURA DE PRECIZIE 30..300 MHZ ETS-LINDGREN 3110C

• Frequency Minimum 30 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 250mW

 

ANTENA HORN GHID DE UNDA DUBLU CRESTATA 100 MHZ..1 GHZ ETS-LINDGREN 3112

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 800 W
• Maximum Power 2 kW

 

ANTENA LOG-PERIODICA POLARITATE LINIARA DUBLA 100 MHZ..1.1 GHZ ETS-LINDGREN 3145BDP

• Frequency Range 100 MHz - 1.1 GHz
• Input Impedance 50 ?
• VSWR 1.5:1 average, 3.5:1 maximum
• Maximum RF input power 800 W
• Stainless Steel Construction
• Dual Linearly Polarized

 

CAMERA DE TEST IZOLATA RF MASURATORI EMC SI ECRANARE ETS-LINDGREN 5230

• Standard dimenssions 600 x 500 x 500 mm
• Progressive Latching
• Large Working Interior
• Up to 120 dB RF Isolation

 

FILTRE PUTERE APLICATII TEMPEST/RFI/ EMI DE MARE PERFORMANTA CURENTI 6..100A ETS-LINDGREN N255X

• Maximum protection in Tempest and EMPP applications
• Highest performing commercially available power line filter
• Over 100dB insertion loss from 10 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

SONDA MASURA CAMP MAGNETIC 300 KHZ..300 MHZ ETS-LINDGREN HI-4433

• Frequency Range: 300 kHz - 300 MHz
• Magnetic Field Sensing: 5-300 MHz
• Automatic Continuous Zeroing
• Data from each axis can be viewed individually
• Isotropic Detection