Camera ecranata acustic testare dispozitive dimensiuni mici ETS-Lindgren SD

Cod: ETS-Lindgren SD


 

Brosura produs PDF, 0.37 Mb

Descriere

  • Acoustically Controlled Test Environment
  • Survey and/or Engineering Grade Measurement
  • Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

APPLICATIONS

  • Automotive Components
  • Quality Assurance/Comparative Analysis
  • Testing of Telephone Handsets or Mounted Transducers for Noise Quality
  • Insertion Measurements of Hearing Aids
  • Evaluation Testing of Microphones or Preamplifiers for Noise Cancellation, Conductivity and Noise Emissions
  • Testing Noise Emissions of Small Parts or Components
  • Head & Torso Testing (SD3)
  • IT Product Noise Testing

 

Product Features and Options

Model #

Chamber Dims Outside (L x W x H)

Chamber Dims Inside (L x W x H)

Features

Applications

Some Applicable Standards

SD

91.4 cm x 86.4 cm x 91.4 cm
(36 in. x 34 in. x 36 in.)

71.1 cm x 66.0 cm x 71.1 cm
(28 in. x 26 in. x 28 in.)

For Testing > 500 Hz
Solid Steel Floor
Cable Ports (2)
Vibration Pads (4)
AS-A504 Walls

Quality Control Comparative Analysis

ISO 3744
ISO 3746
ISO 532B
ISO 11201

SD1

111.8 cm x 111.8 cm x 111.8 cm
(44 in. x 44 in. x 44 in.)

91.4 cm x 91.4 cm x 91.4 cm
(36 in. x 36 in. x 36 in.)

For Testing > 500 Hz
Solid Steel Floor
Cable Ports (2)
Vibration Pads (4)
AS-A504 Walls
Light(1)

Sound Power and
Sound Pressure of
Auto Parts,Computer Parts, and Small Parts

ISO 3744
ISO 3746
ISO 532B
ISO 11201
GMW7293

SD2

152.4 cm x 152.4 cm x 162.6 cm
(60 in. x 60 in. x 64 in.)

121.9 cm x 121.9 cm x 132.1 cm
(48 in. x 48 in. x 52 in.)

For Testing > 500 Hz
Solid Steel Floor
Cable Ports (2)
Vibration Pads (2)
AS-A506 Walls
Light(1)

Engineering Test of Small Parts

ISO 3744
ISO 3746
ISO 532B
ISO 11201
GMW7293
MS14011

SD3

127 cm x 127 cm x 241.3 cm
(50 in. x 50 in. x 95 in.)

106.7 cm x 106.7 cm x 213.4 cm
(42 in. x 42 in. x 84 in.)

For Testing > 500 Hz
Solid Steel Floor
Cable Ports (2)
Vibration Pads (2)
AS-A504 Walls
Light(1)

Head & Torso Testing
Speech Intelligibility
Codec Scoring
End to End Signal Integrity

ISO 3744
ISO 3746
ISO 532B
ISO 11201

 

Accesorii standard

  • Acoustic Walls, Ceiling, and Floor
  • Acoustically Engineered Roof Integrated Ventilation System
  • Light (SD1, SD2, SD3 Only)
  • Sound Absorbing Perforated Steel Interior (Walls and Ceiling)
  • Panelized Floor (Reflective)
  • Floor Vibration Rails, SD2 & SD3
  • Floor Vibration Pads, SD & SD1
  • Cable Ports
    -- 1 ea. 5.1 cm (2 in.)
    -- 1 ea. 2.5 cm (1 in.)
  • Acoustic Door with Window
 

Optiuni recomandate

  • Test Stands (Not Available on SD3)
  • Absorptive Mini Wedges
  • Interior Perforated Floor
  • Stainless Steel Construction
  • Light (SD Only)
  • Ventilation Silencers (SD3 Only)
 

Alte produse ETS-LINDGREN

INTERFATA WIRELESS TESTARE TELEFOANE MOBILE IN COMUNICATII CELULARE ETS-LINDGREN 5211

• Works with Mobile/Cellular Radio Test Sets: HP 8924
• >80 dB Typical RF Isolation
• On-The-Air Test TX, RX Functionality Without Direct Cable connection to Cell Phone Data Port
• Flat Coupling Response over 700 MHz - 2 GHz

 

ANTENA BICONICA MASURA DE PRECIZIE 30..300 MHZ ETS-LINDGREN 3110C

• Frequency Minimum 30 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 250mW

 

BOBINA HELMHOLTZ MONOAXIALA GENERARE CAMP MAGNETIC UNIFORM FRECVENTE JOASE ETS-LINDGREN 6400

• Excellent for Magnetic Immunity Testing
• A Source for Calibration
• Custom Models Available

 

ANTENA BICONICA TESTARE IEC 1000-4-3 20..300 MHZ ETS-LINDGREN 3109

• Frequency Minimum 20 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type omnidirectional
• Peak Power 3 kW
• Polarization linear

 

SONDA MASURA CAMP MAGNETIC 300 KHZ..300 MHZ ETS-LINDGREN HI-4433

• Frequency Range: 300 kHz - 300 MHz
• Magnetic Field Sensing: 5-300 MHz
• Automatic Continuous Zeroing
• Data from each axis can be viewed individually
• Isotropic Detection

 

ANTENA BUCLA PASIVA DE TESTAT ECRANARE SI IMUNITATE RADIATII 10 KHZ..30 MHZ ETS-LINDGREN 6512

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear

 

ANTENA BUCLA CU GENERARE CAMP MAGNETIC FRECVENTA JOASE 20 HZ..50 KHZ ETS-LINDGREN 7603

• Frequency Minimum 20 Hz
• Frequency Maximum 50 kHz
• Connectors Banana Jack (2)
• Impedance (Nominal) 50 ?
• Maximum Input Power 5 A
• Pattern Type omnidirectional
• Polarization linear

 

FILTRE DE CONTROL APLICATII TEMPEST/ EMP/ EMI CURENTI 2..10A ETS-LINDGREN N502X/ N503X

• Current Rating 2 Amps
• Number of Lines 2
• Voltage Frequency Maximum 100/DC
• Current range up to 10 Amperes
• Protection for Tempest and EMP
• Low volt drop
• AC and DC Options

 

CAMERA ECRANATA TESTARE EMI/RFI ETS-LINDGREN 5240

• Ease of operation in a compact, portable format
• Maximum performance Double Electrically Isolated (DEI) RF door with toggle action over center draw latches
• High performance 24 ounce copper shielding construction
• Shielding performance of 120 dB+

 

TESTER MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE LINII TRANSMISIE RETELE ENERGIE ELECTRICA ETS-LINDGREN HI-3604

• Power Line Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings