Camera ecranata acustic testare dispozitive dimensiuni mici ETS-Lindgren SD

Cod: ETS-Lindgren SD


 

Brosura produs PDF, 0.37 Mb

Descriere

  • Acoustically Controlled Test Environment
  • Survey and/or Engineering Grade Measurement
  • Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

APPLICATIONS

  • Automotive Components
  • Quality Assurance/Comparative Analysis
  • Testing of Telephone Handsets or Mounted Transducers for Noise Quality
  • Insertion Measurements of Hearing Aids
  • Evaluation Testing of Microphones or Preamplifiers for Noise Cancellation, Conductivity and Noise Emissions
  • Testing Noise Emissions of Small Parts or Components
  • Head & Torso Testing (SD3)
  • IT Product Noise Testing

 

Product Features and Options

Model #

Chamber Dims Outside (L x W x H)

Chamber Dims Inside (L x W x H)

Features

Applications

Some Applicable Standards

SD

91.4 cm x 86.4 cm x 91.4 cm
(36 in. x 34 in. x 36 in.)

71.1 cm x 66.0 cm x 71.1 cm
(28 in. x 26 in. x 28 in.)

For Testing > 500 Hz
Solid Steel Floor
Cable Ports (2)
Vibration Pads (4)
AS-A504 Walls

Quality Control Comparative Analysis

ISO 3744
ISO 3746
ISO 532B
ISO 11201

SD1

111.8 cm x 111.8 cm x 111.8 cm
(44 in. x 44 in. x 44 in.)

91.4 cm x 91.4 cm x 91.4 cm
(36 in. x 36 in. x 36 in.)

For Testing > 500 Hz
Solid Steel Floor
Cable Ports (2)
Vibration Pads (4)
AS-A504 Walls
Light(1)

Sound Power and
Sound Pressure of
Auto Parts,Computer Parts, and Small Parts

ISO 3744
ISO 3746
ISO 532B
ISO 11201
GMW7293

SD2

152.4 cm x 152.4 cm x 162.6 cm
(60 in. x 60 in. x 64 in.)

121.9 cm x 121.9 cm x 132.1 cm
(48 in. x 48 in. x 52 in.)

For Testing > 500 Hz
Solid Steel Floor
Cable Ports (2)
Vibration Pads (2)
AS-A506 Walls
Light(1)

Engineering Test of Small Parts

ISO 3744
ISO 3746
ISO 532B
ISO 11201
GMW7293
MS14011

SD3

127 cm x 127 cm x 241.3 cm
(50 in. x 50 in. x 95 in.)

106.7 cm x 106.7 cm x 213.4 cm
(42 in. x 42 in. x 84 in.)

For Testing > 500 Hz
Solid Steel Floor
Cable Ports (2)
Vibration Pads (2)
AS-A504 Walls
Light(1)

Head & Torso Testing
Speech Intelligibility
Codec Scoring
End to End Signal Integrity

ISO 3744
ISO 3746
ISO 532B
ISO 11201

 

Accesorii standard

  • Acoustic Walls, Ceiling, and Floor
  • Acoustically Engineered Roof Integrated Ventilation System
  • Light (SD1, SD2, SD3 Only)
  • Sound Absorbing Perforated Steel Interior (Walls and Ceiling)
  • Panelized Floor (Reflective)
  • Floor Vibration Rails, SD2 & SD3
  • Floor Vibration Pads, SD & SD1
  • Cable Ports
    -- 1 ea. 5.1 cm (2 in.)
    -- 1 ea. 2.5 cm (1 in.)
  • Acoustic Door with Window
 

Optiuni recomandate

  • Test Stands (Not Available on SD3)
  • Absorptive Mini Wedges
  • Interior Perforated Floor
  • Stainless Steel Construction
  • Light (SD Only)
  • Ventilation Silencers (SD3 Only)
 

Alte produse ETS-LINDGREN

CAMERA ECRANATA ACUSTIC TESTARE DISPOZITIVE DIMENSIUNI MICI ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

TESTER MASURA RADIATII CAMP ELECTROMAGNETIC EMISE DE MONITOARE VIDEO SI TERMINALE CU DISPLAY ETS-LINDGREN HI-3603

• VDT / VLF Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII RADIATII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ANTENA BUCLA PASIVA TESTARE ECRANARE SI IMUNITATE RADIATII 1 KHZ..30 MHZ ETS-LINDGREN 6509

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Input Power 1 kW
• Pattern Type omnidirectional
• Polarization linear

 

ANTENA BICONICA MASURA DE PRECIZIE 30..300 MHZ ETS-LINDGREN 3110C

• Frequency Minimum 30 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 250mW

 

CELULA GTEM TEST, MASURA, INCERCARI EMISII ELECTROMAGNETICE SI IMUNITATE EMC ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

FILTRE PROTECTIE RETEA MONOFAZATA APLICATII RFI/EMI PUTERE & CURENT INALT 400..800A ETS-LINDGREN N2510

• >3000 Amp capability
• Fully accessible end chambers
• 80 dB Insertion Loss From 100 kHz to 10 GHz
• Excellent strength to weight ratio
• RoHS Compliant and CE Marked for Compliance with the Low Voltage Directive
• High current capability
• Compact design

 

ANTENA LOG-PERIODICA POLARITATE LINIARA 100 MHZ..1 GHZ ETS-LINDGREN 3150

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors 7/8 EIA Flange (others available)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type directional
• Polarization linear

 

ANTENA DIPOL DE PRECIZIE CU EMISIE OMNIDIRECTIONALA TEST IMUNITATE ELECTROMAGNETICA 440..3010 MHZ ETS-LINDGREN 3125

• Frequency Matched to Wireless Device Frequencies: 440..3010 MHz
• IEEE SCC 34 Design
• Designed for AAMI/FDA Test Requirements

 

ANTENA BICONICA TESTARE IEC 1000-4-3 20..300 MHZ ETS-LINDGREN 3109

• Frequency Minimum 20 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type omnidirectional
• Peak Power 3 kW
• Polarization linear