Esders Vakumobil

Cod: Esders Vakumobil


 

Brosura produs PDF, 2.67 Mb

Descriere

A further conclusion of the E.ON Ruhrgas report is that increasing the throughput of the applied suction system will lead to even better results.

 

However we see limits here in both the costs for the vacuum system and also for handling because the costs and the weight of larger pumps increase disproportionably in relation to performance.

The advantage of the Vakumobil, however, is its work capability both from out of the vehicle (in the portable version) and also the possibility of quickly moving the compact system or operating it at exposed locations. Furthermore, even smaller vehicles with limited space and tolerably low vehicle payload are used when looking for gas leaks.

Therefore, our plan is to keep the existing sizes. Should situations then occur which require even more capacity; two Vakumobil can be used effortlessly at the same time. Depending on the size of the gas diffusion, three or six suction pumps are then connected to every Vakumobil. Equal number of connected suction probes ensue the same vacuum for every probe and therefore, optimal suction. There is also double suction performance for doubled costs. This variety of uses offers a flexible solution and very good cost effectiveness.

The new suction probes and accessory parts are available immediately and they can naturally be used with existing systems.

 

Alte produse ESDERS

ESDERS GASCAM® SG CAMERA VIZUALIZARE SCURGERI GAZ METAN

• Infrared Lens
• Detector unit
• Lithium-ion rechargeable battery packs
• Tripod with swivel/tilt head
• High performance Notebook

 

ESDERS GOLIATH ANALIZOR DE GAZE

• Time-tested Esders operation concept.
• Very quick initial break-in phase after being switching on or changing application.
• Extremely short reaction times when measuring CH4 and CO2 in all concentrations.
• Oxygen and up to 3 toxic gas sensors are available as an option.
• Ethane analysis with automatic measurement result assessment can be integrated.
• Optional pressure measuring up to 2,000 hPa.

 

ESDERS HUNTER DETECTOR SI ANALIZOR SCAPARI DE GAZE

• Cast carpet mat free from the material wear common in deep drawn mats
• Stabilising mould elements enable optimal fit on the ground and enable the carpet to be pulled backwards
• Comprehensive flow channels for sampling

 

ESDERS SIGI EX TESTER GAZE INFLAMABILE

• Improved sensor technology and adjustment options
• Increased operating temperature range of -20 to +50 ° C
• By up to 44% larger display area for better readability
• Red backlight for improved perception of alarm messages

 

ESDERS MULTI GAS DETECTOR H2S CO O2 LEL

• 2 month battery life on a single charge (infrared version)
• Compact and lightweight
• Low maintenance cost
• Simple to use
• LEL sensor (IR) does not require oxygen

 

ESDERS TONI GASTEST CH4 DETECTOR SCURGERI GAZ METAN

• Interval de măsurare: 0 - 10.000 ppm metan
• Timp de răspuns foarte rapid
• Robust, portabil, cu protecţie IP64
• Alarmă de vibraţii şi afișaj digital
• Fabricat în Germania

 

ESDERS GASTEST DELTA3 TESTER GAZ CONFORM DVGW-TRGI 2008

• Usability test in accordance with G5952 or Esders express procedure
• Leak detection via external, digital hand sensor with integrated calibration and vibration alarm
• Automatic and manual test on controllers and safety valves
• Leak test with 150 mbar, strength test with 1 bar
• Pressure measurement up to 25 bar via external sensors

 

ESDERS VACUUM-PROBES-SYSTEM VSS 15

• Complete with connection cable and metal plug
• Stainless steel design with coarse filter and integrated water barrier
• Complete with connection cable and metal bush

 

ESDERS VAKUMOBIL

• The Esders Vakumobil has a markedly improved suction power compared to conventional technology.
• The low pressure in the surface generated by one suction probe has an impact over several metres.
• This creates only a movement or distortion of the gas accumulation but not there elimination.

 

ESDERS SAFE ETHANTEST TESTER GAZ ETAN

• Taking the service box to the measurement site
• Activate device and connect sensor
• Feed sensor into sensor hole and start analysis at the touch of a button
• SAFE absorbs a gas sample and displays its concentration in vol.%
• The gas sample passes through the chromatographic column and the display of methane and ethane (if applicable) takes place