Mono-Axial Accelerometer and Triaxial Accelerometer ICP mechanical vibrations Delta Ohm

Code: Delta Ohm Accelerometers


 

Datasheet PDF, 0.32 Mb

Description

Accelerometer models

HD356A02: tri-axial accelerometer for the measurement of vibrations transmitted to the handarm system; sensitivity of 10mV/g and maximum acceleration equal to 500g. This sensor is mainly used for hand-arm measurements.

 

HD356B21: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system; sensitivity of 10mV/g and maximum acceleration equal to 500g. This sensor is mainly used for hand-arm measurements.

 

HD356B41: tri-axial accelerometer inserted in a rubber pad for the measurement of the vibrations trasnmitted to the whole body. 3m connection cable to the HD2030 analyser included. Sensitivity 100mV/g and maximum acceleration 10g.

 

HD356A22: tri-axial accelerometer for general application with sensitivity of 100mV/g and maximum acceleration equal to 50g.

 

HD352C34: mono-axial accelerometer for general application with nominal sensitivity of 100mV/g and maximum acceleration equal to 50g.

 

HD356B20: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system at high shock level. Sensitivity of 1mV/g and maximum acceleration equal to 5000g.

 

More products SENSECA

CENTESIMAL THERMOMETER DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2

• Centesimal thermometer in the range +/-199.99°C, decimal outside this range
• one input for Pt100 probes with SICRAM module measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power

 

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD2256.2

• Bench-top pHmeter-Conductivity meter-Thermometer with back-lighted display,
• to measure pH, mV, ORP by pH, redox, separated reference electrodes, one input for a pH/temperature combined probe,
• it measures conductivity, liquid resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes with
• 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger for pH or mV, conductivity or resistivity or TDS and temperature.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.

 

SOUND LEVEL CALIBRATOR WITH AUDIO SIGNAL GENERATOR FOR ACOUSTIC CALIBRATIONS CLASS I/II DELTA OHM HD9101 HD9102

• generator noise level 9101/HD HD 9102
• portable, battery-powered sound source,
• suitable for calibration of sound level meters (portable and laboratory) and acoustic measuring stations
• possible to calibrate directly microphones 1 / 2 "of mechanical dimensions conform to the requirements of IEC 61094-1
• the frequency of the sound signal at 1000Hz can perform calibration of sound level meters with any frequency weighting
• sound pressure level generated is independent of atmospheric pressure
• Ease of use allows the use even by unskilled personnel.

 

METEO DATALOGGER WITH DATA ACQUISITION AND RECORDING DELTA OHM HD32MT.1

• 16-channel data logger capable of capturing and logging the values measured by a series of sensors connected to its inputs
• Sensors with analog voltage output, both unipolar and bipolar
• Sensors with analog current output(0..20mA, 4..20mA)
• Temperature sensors thermocouple(typpe K, J, T, N, R, S, B, E)
• Pt100/Pt1000 and NTC temperature sensors
• Sensors with digital output TTL level pulse (ON/OFF)
• Sensors with open/close contact output(e.g. rain gauges, cup anemometers

 

MICRO MANOMETER-THERMOMETER DELTA OHM HD2114P HD2134P

• Micromanometer-Thermometer for air speed and flow rate measurement by means of Pitot tubes
• full scale 20mbar for speed measurements from 2...55m/s.
• Temperature measurement by K type thermocouple.
• Datalogger which stores the maximum, minimum, average value and can store up to 36,000 couples of samples.
• RS232C/ USB output for data transfer in real time to a PC or printer

 

FOUR-CHANNEL VIBRATION ANALYZER FOR WORKERS PROTECTION RISK DELTA OHM HD2030

• portable vibration analyzer performing spectral and statistical analysis on four channels simultaneously
• measures all parameters required by current regulations concerning workers protection from vibration related risks
• measure vibrations transmitted to both hand-arm and whole body
• satisfies the specifications of standards ISO 8041:2005, ISO 5349-1:2001 (handarm vibrations)
• ISO 2631-1, 2 and 4 1997 (whole-body vibrations)
• detects accelerations on four axes through two accelerometers with integrated amplifying electronics

 

ANEMOMETER-THERMOMETER AIR SPEED MEASUREMENT DELTA OHM HD2303.0

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

ALBEDOMETER PYRANOMETER FOR GLOBAL INCIDENT SOLAR RADIATION DELTA OHM LPPYRA05

• Albedometer First and Second Class pyranometers according to ISO 9060.
• Complete with: upper and bottom shade disk, desiccant sachet with silica-gel crystals, 2 cartridges, levelling device, support bracket
• calibration report.
• On request 5 or 10m cables with connectors.

 

MANOMETERS-THERMOMETERS DELTA OHM HD2114 HD2134 HD2164

• portable instruments with a large LCD display
• They measure absolute, relative and differential pressure, as well as temperature
• Max, Min and Avg function calculates the maximum, minimum or average values
• relative measurement REL, the HOLD function, and the automatic turning off
• store up to 36,000 samples
• standard RS232C serial port and USB 2.0

 

NET RADIOMETER FOR ULTRAVIOLET TO INFRARED SOLAR RADIATION MEASUREMENT DELTA OHM LP NET07

• LP NET 07 measures the net radiation across a surface, from near ultraviolet to
• far infrared.
• The Net radiation is defined as the difference between the radiation that reaches the upper surface and the irradiation on the lower surface of the net radiometer.
• The surface of the upper receiver measures the direct solar radiation plus the diffuse one and the radiation at longer wavelengths emitted from the sky (clouds), while the lower receiving area measures the solar radiation reflected from the ground (albedo) and the radiation length wavelengths emitted from the earth.
• The instrument is designed and constructed to be used outdoors in any weather
• conditions.