3-Channel Multifunction Air Parameters Monitoring Datalogger Delta Ohm DO9847

Code: Delta Ohm DO9847


 

Datasheet PDF, 2.08 Mb
           

Description

Multifunctional handheld board instrument and datalogger. Provided with a 128x64 pixel (56x38 mm) graphic display and three independent inputs. Each input can be connected to one channel or two channel dual probes (ex. two thermocouples, relative humidity/temperature, etc.).
The instrument automatically recognises SICRAM probes connected to the input (memory equipped and configurable intelligent probe).
Functions: watch, hold, max., min., average, record, immediate or deferred start record logging, difference between the two inputs, relative measures, three input channel measurement and inside reference temperature display.
Sampling time: one per second/input.
Probe calibration through SICRAM module; calibration data permanent storage inside the probe.
Storage capacity: 32.000 readings per input.
Storage interval and printing can be configured between one second and 1 hour.
RS232C serial output: from 300 up to 115.200 baud rate.
Immediate or deferred print-out.
Stored data can be displayed and stored data blocks can be deleted.
Automatic shutout after 8 minutes can be disabled.
Units of measurement can be selected according to the physical quantity of the connected probe.

Firmware update through RS232C serial port. Different types of SICRAM modules or probes can be connected to the input: Platinum sensor temperature, thermocouple, relative humidity/temperature, Discomfort index, continuous voltage (±20V), current (0...24mA), pressure, air speed and light.

Delivered including application software (Windows7® compatible) in a rugged carryingcase.

 

More products SENSECA

THERMO HYGROMETER DELTA OHM HD2101.1 HD2101.2

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

DATALOGGER PHOTO-RADIOMETER FOR SOLAR LIGHT, TEMPERATURE DELTA OHM DO9721

• Datalogger Photo-radiometer Thermometer which performs photometric, radiometric, PAR, temperature measurements.
• Two inputs.
• Function as datalogger: 30,000 samples, REL, Record, Q (integration),
• RS232C serial output

 

FIRST CLASS PYRHELIOMETER FOR DIRECT SOLAR IRRADIANCE MEASUREMENT DELTA OHM LP PIRHE16

• The pyrheliometer LP PYRHE 16 First Class Pyrheliometer according to ISO 9060 classification
• is an instrument for direct measurement of solar irradiance (Watt/m2).
• The receiving surface must be positioned (via a solar tracker or else) perpendicularly to sun’s rays.
• By using suitable diaphragms only the direct light reaches the surface of the sensor.
• According to WMO (Seventh Edition 2008) and ISO 9069 regulations, the pyrheliometer has a field of view of 5°.

 

HVACR DATALOGGER FOR AIR SPEED, FLOW, PRESSURE, TEMPERATURE DELTA OHM DO2003

• HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes,
• Pt100 temperature probes for immersion, pointed and for surface,
• combined temperature/relative humidity probes.
• Pressure up to 2000 mbar and barometric pressure.
• Max-Min-Med, Rel measurements.
• Storage up to 12,000 readings.
• Serial output RS232C


NET RADIOMETER WITH 4-COMPONENTS FOR SOLAR RADIATION MEASUREMENTS DELTA OHM LP NET14

• LP NET 14 is a 4-component net-radiometer for the measurement of the net radiation between 0.3µm and 45 µm.
• consists of two pyranometers: one for the measurement of the global radiation Esw? and the other one for the measurement of the reflected solar radiation Esw?
• pair of pyrgeometers: one for the measurement of the infrared radiation emitted by the sky EFIR? and the other one for the infrared emitted by the ground surface EFIR?
• equipped with a temperature sensor (NTC).

 

MANOMETERS-THERMOMETERS DELTA OHM HD2114 HD2134 HD2164

• portable instruments with a large LCD display
• They measure absolute, relative and differential pressure, as well as temperature
• Max, Min and Avg function calculates the maximum, minimum or average values
• relative measurement REL, the HOLD function, and the automatic turning off
• store up to 36,000 samples
• standard RS232C serial port and USB 2.0

 

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD2256.2

• Bench-top pHmeter-Conductivity meter-Thermometer with back-lighted display,
• to measure pH, mV, ORP by pH, redox, separated reference electrodes, one input for a pH/temperature combined probe,
• it measures conductivity, liquid resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes with
• 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger for pH or mV, conductivity or resistivity or TDS and temperature.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.

 

8-16 CHANNEL TEMPERATURE DATALOGGER DELTA OHM HD32.7 HD32.8.8 HD32.8.16

• HD32.7 - 8 INPUTS DATA LOGGER FOR pt100 SENSOR PROBES
• HD32.8.8/ HD32.8.16 Rugged data logger with 8/16 inputs for K, J, T, N, R, S, B and E type thermocouple with miniature connector temperature probes
• Unit of measurement °C, °F, °K configurable.
• Data logging: instantaneous or postponed, with the possibility of selecting the storage start and end.
• Data download: RS232C, 1200...38400 baud or USB 1.1 - 2.0.
• DeltaLog9 software for data download and processing.

 

HANDHELD DIGITAL THERMOCOUPLE THERMOMETER K J T E DELTA OHM HD2328.0

• Thermocouple thermometer for probes type K, J, T, E
• Two inputs for miniature thermocouple connectors
• Storage of maximum, minimum, average valu
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

MANOMETER THERMOMETER DIGITAL HANDHELD DELTA OHM HD2304.0

• Manometer-Thermometer with one input for SICRAM module PP471 to connect probes TP704 and TP705 series
• Temperature measurement with Pt100 probe complete with SICRAM module, measuring range 200°C +650°C.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,