pH and mV-meter simulator calibrating kit Delta Ohm HD9609

Code: Delta Ohm HD9609


 

Datasheet PDF, 0.15 Mb

Description

pH/mV simulator kit composed of instrument HD9609,

adapter cables CP 9509/T,

CP9509/BNC and

carrying case.

 

More products SENSECA

HVACR DATALOGGER FOR AIR SPEED, FLOW, PRESSURE, TEMPERATURE DELTA OHM DO2003

• HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes,
• Pt100 temperature probes for immersion, pointed and for surface,
• combined temperature/relative humidity probes.
• Pressure up to 2000 mbar and barometric pressure.
• Max-Min-Med, Rel measurements.
• Storage up to 12,000 readings.
• Serial output RS232C


CENTESIMAL THERMOMETER DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2

• Centesimal thermometer in the range +/-199.99°C, decimal outside this range
• one input for Pt100 probes with SICRAM module measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power

 

ALBEDOMETER PYRANOMETER FOR GLOBAL INCIDENT SOLAR RADIATION DELTA OHM LPPYRA05

• Albedometer First and Second Class pyranometers according to ISO 9060.
• Complete with: upper and bottom shade disk, desiccant sachet with silica-gel crystals, 2 cartridges, levelling device, support bracket
• calibration report.
• On request 5 or 10m cables with connectors.

 

SOUND LEVEL CALIBRATOR FOR MICROPHONES AND ACOUSTIC STATIONS DELTA OHM HD2020

• HD 2020 sound level calibrator
• portable, battery operated sound source
• suitable for sound level meters (portable and laboratory) and acoustic stations
• class 1 according to IEC60942:2003 with LCD display.
• ISO 9001 calibration report included.
• 1000Hz frequency allows calibrating sound level meters with any weighting

 

LABORATORY TESTER FOR ELECTROCHEMICAL PARAMETERS: PH, CONDUCTIVITY, DISSOLVED OXYGEN, TEMPERATURE, CONCENTRATION, SOLIDS, SALINITY DELTA OHM HD22569.2

• bench top instrument for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature.
• It is are fitted with a large backlighted LCD display.
• pH, mV, redox potential (ORP) with pH, redox electrodes or electrodes with separate reference;
• conductivity, resistivity in liquids,
• total dissolved solids (TDS) and salinity with combined 4-ring and 2-ring conductivity/
• temperature probes with direct input or SICRAM module;
• concentration of dissolved oxygen in liquids (in mg/l) and saturation index (in %),

 

PORTABLE LABORATORY TURBIDITY-METER FOR LPROCESS IQUIDS, DRINKING WATER, WASTE WATER DELTA OHM HD25.2

• Portable and bench turbidity meter equipped with 3 photodetectors and two light sources
• it measures according to the standard EPA 180.1, ISO-NEPH (ISO 7027), EBC and ASBC.
• Automatic calibration,
• datalogger,
• data downloading to PC by RS232C or USB 2.0 through the software DeltaLog11

 

PORTABLE PH-METER WITH THERMOMETER DELTA OHM HD2305.0

• pHmeter-Thermometer which measures pH, mV and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

CONDUCTIVIMETER-THERMOMETER FOR CONDUCTIVITY, LIQUID RESISTIVITY, DISSOLVED SOLIDS, SALINITY, TEMPERATURE DELTA OHM HD2306.0

• Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

ANEMOMETER-THERMOMETER AIR SPEED MEASUREMENT DELTA OHM HD2303.0

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

PORTABLE PHOTO-RADIOMETER DATALOGGER TO MEASURE NON-COHERENT OPTICAL RADIATION ACC.EUROPEAN DIRECTIVE 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.