Integrating Sound Level Meter Class I or Class II with Spectral Analysis & Statistics Delta Ohm HD2010UC

Code: Delta Ohm HD2010UC


 

Datasheet PDF, 0.37 Mb
             

Description

HD2010UC kit1 is an integrating portable sound level meter performing statistical analysis.

The instrument has been designed combining maximum low cost and simplicity of use. Attention has been paid to the possibility of adjusting the instrument and adding options at any time to the HD2010UC so to extend its applications. The user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument.

 

Technical regulations:
• Class 1 sound level meter according to IEC 61672-1 dated 2002 (Certificate of Compliance I.N.RI.M. n. 07-0124-02), IEC 60651 and IEC 60804.

 

 

Applications:
• Assessment of the environmental noise level,
• Optional "data logging" function,
• Optional capture and analysis of sound events,
• Statistical analysis with the calculation of 3 percentile level and optional full statistical analysis,
• Identification of impulsive noises,
• Measurements in workplaces,
• Selection of personal protective equipments (SNR and HML methods),
• Production quality control,
• Measurement of machine noise.

Sound level meter class 1 or 2 Kit
• HD2010UC kit1 and kit2: consists of HD2010UC sound level meter class 1, HD2010PNE2 preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2), windscreen, 5m extension cable and serial RS232 or USB connection cable. Noise Studio PC programme.
• HD2010UC kit1/E: version for outdoor measurements, it consists of HD2010UC sound level meter class 1, HD WME weatherproof microphone unit for outdoor use, HD2010PNE2W heated preamplifier, UC52/1 microphone for free field (UC52 for HD2010UC kit2) and serial RS232 or USB connection cable. Noise Studio PC programme
• HD2010UC kit1/IE: version for indoor and outdoor measurements, It consists of HD2110 Sound Level Meter, HD WME weatherproof microphone unit, HD2110PWheated preamplifier, preamplifier HD2110P, MK223 microphone cartridge for free field, windscreen HD SAV, 5m extension cable CPA/5 and RS232 serial or USB connection cable. Noise Studio PC program.

Calibration of soundlevel meters: Delta Ohm can carry out all calibrations according to international recognized standards.

 

Calibrator class 1 for this instrument: HD2020

 

These kits are also available as class 2 soundlevel measurement: HD2010UC Class 2

 

 

 

 

HD2010UC kit 2 is an integrating portable sound level meter performing statistical analysis.

The instrument has been designed combining maximum low cost and simplicity of use. Attention has been paid to the possibility of adjusting the instrument and adding options at any time to the HD2010UC so to extend its applications. The user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument.

 

Technical regulations:
• Class 2 sound level meter according to IEC 61672-1 dated 2002 (Certificate of Compliance I.N.RI.M. n. 07-0124-02), IEC 60651 and IEC 60804.

 

Applications:
• Assessment of the environmental noise level,
• Optional "data logging" function,
• Optional capture and analysis of sound events,
• Statistical analysis with the calculation of 3 percentile level and optional full statistical analysis,
• Identification of impulsive noises,
• Measurements in workplaces,
• Selection of personal protective equipments (SNR and HML methods),
• Production quality control,
• Measurement of machine noise.

 

Sound level meter class 2

• HD2010UC kit 2: consists of HD2010UC sound level meter class 2, HD2010PNE2 preamplifier, UC52/1 microphone for free field, windscreen, 5m extension cable and serial RS232 or USB connection cable. Noise Studio PC programme.

 

Standard accessories

 

 

More products SENSECA

RADIOMETRIC PROBE FOR OUTDOOR MEASURING OF SOLAR IRRADIANCE DELTA OHM LP UVA02

• Radiometric probe for outdoor use for measuring IRRADIANCE in the range UVA (315...400nm).
• mV per mW/cm2 output.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors

 

DATALOOGER WITH MICROCLIMATE ANALYSIS WBGT PMV PPD DELTA OHM HD32.3 HD32.3A

• Analysis of hot environments using WBGT index
• Analysis of the moderate warm environments using PMV index and PPD index
• Logging
• Start and stop can be set automatically with the auto-start function
• Selectable measurement unit of the temperature: °C, °F, °K.
• Date and time of the instrument.

 

METEO DATALOGGER WITH DATA ACQUISITION AND RECORDING DELTA OHM HD32MT.1

• 16-channel data logger capable of capturing and logging the values measured by a series of sensors connected to its inputs
• Sensors with analog voltage output, both unipolar and bipolar
• Sensors with analog current output(0..20mA, 4..20mA)
• Temperature sensors thermocouple(typpe K, J, T, N, R, S, B, E)
• Pt100/Pt1000 and NTC temperature sensors
• Sensors with digital output TTL level pulse (ON/OFF)
• Sensors with open/close contact output(e.g. rain gauges, cup anemometers

 

MULTIPARAMETRIC TESTER FOR ELECTROCHEMICAL MEASUREMENTS: PH, CONDUCTIVITY, DISSOLVED OXYGEN, TEMPERATURE, CONCENTRATION, SOLIDS, SALINITY DELTA OHM HD98569

• portable multi-parameter data logger for electrochemical measures: pH, conductivity, dissolved oxygen and temperature
• large back-lighted LCD display
• pH, mV, redox potential (ORP) with pH, redox or combined pH/temperature electrodes complete with SICRAM module
• conductivity, resistivity in liquids, total dissolved solids (TDS), and salinity with combined 4-ring and 2-ring conductivity and temperature probes with SICRAM module.
• Concentration of dissolved oxygen in liquids (in mg/l), saturation index (in %)

 

LUXMETER PHOTO- RADIOMETER MEASURING SOLAR ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2102.1 HD2102.2

• Device for measuring illuminance, luminance, PAR, irradiance.
• Storage of maximum, minimum, average value and the integral Q(t),
• RS232 C output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

PORTABLE PHOTO-RADIOMETER DATALOGGER TO MEASURE NON-COHERENT OPTICAL RADIATION ACC.EUROPEAN DIRECTIVE 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

ANEMOMETER-THERMOMETER DELTA OHM HD2103.1 HD2103.2

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.
• RS232C/USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP67 protection degree.

 

LABORATORY BENCHTOP CONDUCTIVITY-METER-THERMOMETER WITH LIQUID RESISTIVITY, DISSOLVED SOLIDS TDS DELTA OHM HD2206.2

• Bench-top conductivity meter-Thermometer with back-lighted display,
• with inputs for measurements of conductivity, liquid resistivity, total dissolved solids (TDS) and the salinity by conductivity and temperature
• combined probes with 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger of conductivity or resistivity or TDS and temperature.
• RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time.
• Input for Pt100 or Pt1000 temperature probes provided with SICRAM module.

 

AIR QUALITY ANALYSIS MONITORING DATALOGGER CO CO2 DELTA OHM HD37AB17D HD37B17D

• data loggers able to measure and memorize simultaneously the following parameters:
• Relative Humidity RH
• Environment temperature T
• Carbon monoxide CO (only HD37AB17D)
• Carbon dioxide CO2
• DeltaLog13 communication software via the USB port

 

FOUR-CHANNEL VIBRATION ANALYZER FOR WORKERS PROTECTION RISK DELTA OHM HD2030

• portable vibration analyzer performing spectral and statistical analysis on four channels simultaneously
• measures all parameters required by current regulations concerning workers protection from vibration related risks
• measure vibrations transmitted to both hand-arm and whole body
• satisfies the specifications of standards ISO 8041:2005, ISO 5349-1:2001 (handarm vibrations)
• ISO 2631-1, 2 and 4 1997 (whole-body vibrations)
• detects accelerations on four axes through two accelerometers with integrated amplifying electronics