Datalooger with Microclimate analysis WBGT Delta Ohm HD32.2 HD32.2A

Code: Delta Ohm HD32.2 HD32.2A


 

Datasheet PDF, 0.85 Mb
 

Description

HD32.2 - WBGT Index is an instrument made by Delta Ohm srl for the analysis of WBGT index (Wet Bulb Glob Temperature: wet bulb temperature and globe thermometer temperature) in presence or in absence of solar radiation.

Reference Regulations:
ISO 7243: Hot environments. Estimation of the heat stress on working man, based on WBGT index (wet bulb temperature and Globe thermometer).
ISO 8996: Ergonomics of the thermal environment - Determination of the energy metabolism.
ISO 7726: Ergonomics of the thermal environment - Instruments for measuring physical quantities.
The instrument is provided with three inputs for probes with SICRAM module:
the SICRAM module interface between the instrument and sensor connected and communicate the sensor parameters and calibration data to the instrument.
All SICRAM probes can be plugged into any of the inputs: they are
automatically recognized upon turning the Instrument on.
The main features of the instrument are:

  • Logging: data acquisition and logging to the integral instrument memory.

Storage capacity: 64 different logging sections, sample interval, user selectable.

  • You can set the automatic logging start with auto-start function( Start/Stop time ).
  • The measurement unit of the temperature: °C, °F, °K.
  • Date and time of the instrument.
  • The display of maximum, minimum, medium statistic parameters and their deletion.

• The data transfer speed via the RS232 serial port.

HD32.2 instrument can detect simultaneously the following quantities:

  • Globe thermometer temperature Tg.
  • Wet bulb temperature with natural ventilation Tn.
  • Environment temperature T. Starting from the detected values, HD32.2 can calculate:
  • WBGT(in) index (Wet Bulb Glob Temperature: wet bulb temperature and Globe thermometer) in absence of solar radiation.

• WBGT(out) index (Wet Bulb Glob Temperature wet bulb temperature and Globe thermometer) in presence of solar radiation. 

Thermal microclimate to measure the WBGT Index in Moderate Environments. 3 inputs for probes with SICRAM module, graphic display, four 1.5V AA batteries, instruction manual, software Deltalog 10 Hot Environment with WBGT index analysis.

These probes are requested for the WBGT measurement: · Dry bulb temperature probe TP3207.2. · Globe temperature probe TP3276.2. · Natural ventilated wet bulb temperature probe HP3201.2.

 

More products SENSECA

SOUND LEVEL CALIBRATOR FOR MICROPHONES AND ACOUSTIC STATIONS DELTA OHM HD2020

• HD 2020 sound level calibrator
• portable, battery operated sound source
• suitable for sound level meters (portable and laboratory) and acoustic stations
• class 1 according to IEC60942:2003 with LCD display.
• ISO 9001 calibration report included.
• 1000Hz frequency allows calibrating sound level meters with any weighting

 

LABORATORY ELECTROCHEMICAL MULTIPARATEMER TESTER FOR DISSLVED OXIGEN, CONCENTRATION, SATURATION INDEX DELTA OHM HD3409.2

• Bench-top Oxymeter-Thermometer measures dissolved oxygen,
• saturation index by polarographic type combined probes,
• temperature by Pt100 probes with SICRAM module.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

INTEGRATING SOUND LEVEL METER CLASS I / CLASS II WITH DATALOGGING, SPECTRAL ANALYSIS & STATISTICS DELTA OHM HD2010UC/A

• portable integrating class 1 sound level meter, with data logging function, suitable for performing statistical and spectral analyses
• possibility of adjusting the instrument and adding options at any time
• user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument
• Class 1 or 2 sound level meter according to IEC 61672-1 IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Assessment of the environmental noise level,
• Noise monitoring and optional capture and analysis of sound events,
• Octave and optional third octave band spectrum analysis from 25 Hz to 12.5 kHz,

 

SECONDARY CLASS PYRANOMETER FOR DIRECT SOLAR IRRADIANCE ON FLAT SURFACE AND GLOBAL RADIATION DELTA OHM LP PYRA10

• measures the irradiance on a flat surface (Watt/m2)
• pyranometer classified as Secondary in accordance with ISO 9060
• according to the publication "Guide to Meteorological Instruments and Methods of Observation", fifth edition (1983) of WMO
• LP PYRA 10 PASSIVE *
• LP PYRA 10 AC ACTIVE with CURRENT 4..20 mA output
• LP PYRA 10 AV ACTIVE with VOLTAGE 0..1 V, 0..5 V, 0..10 V output

 

PORTABLE PHOTO-RADIOMETER DATALOGGER TO MEASURE NON-COHERENT OPTICAL RADIATION ACC.EUROPEAN DIRECTIVE 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD2256.2

• Bench-top pHmeter-Conductivity meter-Thermometer with back-lighted display,
• to measure pH, mV, ORP by pH, redox, separated reference electrodes, one input for a pH/temperature combined probe,
• it measures conductivity, liquid resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes with
• 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger for pH or mV, conductivity or resistivity or TDS and temperature.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.

 

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD3456.2

• Bench-top pHmeter-Conductivity meter-Thermometer
• measures pH, mV, ORP values by pH, redox or separated reference electrodes, conductivity,
• liquids resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

MULTIPARAMETRIC TESTER FOR ELECTROCHEMICAL MEASUREMENTS: PH, CONDUCTIVITY, DISSOLVED OXYGEN, TEMPERATURE, CONCENTRATION, SOLIDS, SALINITY DELTA OHM HD98569

• portable multi-parameter data logger for electrochemical measures: pH, conductivity, dissolved oxygen and temperature
• large back-lighted LCD display
• pH, mV, redox potential (ORP) with pH, redox or combined pH/temperature electrodes complete with SICRAM module
• conductivity, resistivity in liquids, total dissolved solids (TDS), and salinity with combined 4-ring and 2-ring conductivity and temperature probes with SICRAM module.
• Concentration of dissolved oxygen in liquids (in mg/l), saturation index (in %)

 

SECONDARY CLSSS PYRANOMETER ACCORDING TO WMO STANDARD ISO9060 DELTA OHM LP PYRA08

• Second class pyranometer according to ISO 9060,
• fast response sensor complete with calibration report,
• possibility to replace the exhausted silica-gel.
• Different configurations available.
• Male M12 connector.
• On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.

 

PORTABLE CLASS I INTEGRATING SOUND LEVEL METER WITH SPECTRUM ANALYSIS ANS STATISTICS DELTA OHM HD2010

• precision integrating portable sound level meter
• data logging functions
• performing both spectrum and statistical analysis
• maximum flexibility and simplicity
• firmware can be directly updated by the user by means of the Noise Studio program supplied with the instrument
• Class 1 sound level meter according to IEC 61672-1, 2002
• Class 1 octave and third octave filters according to IEC 61260
• Microphone complying with IEC 61094-4
• Noise monitoring and optional capture and analysis of sound events
• Octave and optional third octave band spectrum analysis from 16 Hz to 20 kHz