Luxmeter Radiometer measuring illuminance, PAR, irradiance Delta Ohm HD2302.0 HD2302.0VP474

Code: Delta Ohm HD2302.0 HD2302.0VP474


 

Datasheet PDF, 0.49 Mb

Description

HD2303.0 Device for measuring illuminance, luminance, PAR, irradiance. Storage of maximum, minimum, average value. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree. Complete with carrying case, instruction manual, 3 batteries. LP471. series probes with SICRAM module are suitable. The probes have to be ordered separately.

 

 

HD2302.0VP474 Radiometer complete with SICRAM module. A pyranometer such as LP PYRA02AV or LP PYRA03AV can be connected. The instrument displays the values in W/m2. The order has to be placed for: instrument, pyra­no­meter and connection cable. The kit includes instrument, module VP474, carrying case, instruction manual, 3 batteries. The pyranometer at choice between LP PYRA02AV or LP PYRA03AV, the cable (CP AA 1.5 or CP AA 1.10) and any other LP471 series probes have to be ordered separately. The kit has to be configured by the manufacturer.

 

More products SENSECA

DUAL INPUT THERMOMETER DELTA OHM HD2178.1 HD2178.2

• Thermometer with two inputs, the first for Pt100 probes equipped with SICRAM module, the second input for thermocouple type K, J, T, E, N
• large display
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

MANOMETER THERMOMETER DIGITAL HANDHELD DELTA OHM HD2304.0

• Manometer-Thermometer with one input for SICRAM module PP471 to connect probes TP704 and TP705 series
• Temperature measurement with Pt100 probe complete with SICRAM module, measuring range 200°C +650°C.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

SECONDARY CLSSS PYRANOMETER ACCORDING TO WMO STANDARD ISO9060 DELTA OHM LP PYRA08

• Second class pyranometer according to ISO 9060,
• fast response sensor complete with calibration report,
• possibility to replace the exhausted silica-gel.
• Different configurations available.
• Male M12 connector.
• On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.

 

MANOMETERS-THERMOMETERS DELTA OHM HD2114 HD2134 HD2164

• portable instruments with a large LCD display
• They measure absolute, relative and differential pressure, as well as temperature
• Max, Min and Avg function calculates the maximum, minimum or average values
• relative measurement REL, the HOLD function, and the automatic turning off
• store up to 36,000 samples
• standard RS232C serial port and USB 2.0

 

CONDUCTIVIMETER-THERMOMETER FOR CONDUCTIVITY, LIQUID RESISTIVITY, DISSOLVED SOLIDS, SALINITY, TEMPERATURE DELTA OHM HD2306.0

• Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

SECONDARY CLASS PYRANOMETER FOR DIRECT SOLAR IRRADIANCE ON FLAT SURFACE AND GLOBAL RADIATION DELTA OHM LP PYRA10

• measures the irradiance on a flat surface (Watt/m2)
• pyranometer classified as Secondary in accordance with ISO 9060
• according to the publication "Guide to Meteorological Instruments and Methods of Observation", fifth edition (1983) of WMO
• LP PYRA 10 PASSIVE *
• LP PYRA 10 AC ACTIVE with CURRENT 4..20 mA output
• LP PYRA 10 AV ACTIVE with VOLTAGE 0..1 V, 0..5 V, 0..10 V output

 

DATALOOGER WITH MICROCLIMATE ANALYSIS WBGT DELTA OHM HD32.2 HD32.2A

• analysis of WBGT index (Wet Bulb Glob Temperature: wet bulb temperature and globe thermometer temperature) in presence or in absence of solar radiation
• Logging
• data transfer speed via the RS232 serial port
• The measurement unit of the temperature: °C, °F, °K
• Date and time of the instrument
• display of maximum, minimum, medium statistic parameters and their deletion

 

PORTABLE PHOTO-RADIOMETER DATALOGGER TO MEASURE NON-COHERENT OPTICAL RADIATION ACC.EUROPEAN DIRECTIVE 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

ALBEDOMETER PYRANOMETER FOR GLOBAL INCIDENT SOLAR RADIATION DELTA OHM LPPYRA05

• Albedometer First and Second Class pyranometers according to ISO 9060.
• Complete with: upper and bottom shade disk, desiccant sachet with silica-gel crystals, 2 cartridges, levelling device, support bracket
• calibration report.
• On request 5 or 10m cables with connectors.

 

MULTIPARAMETRIC TESTER FOR ELECTROCHEMICAL MEASUREMENTS: PH, CONDUCTIVITY, DISSOLVED OXYGEN, TEMPERATURE, CONCENTRATION, SOLIDS, SALINITY DELTA OHM HD98569

• portable multi-parameter data logger for electrochemical measures: pH, conductivity, dissolved oxygen and temperature
• large back-lighted LCD display
• pH, mV, redox potential (ORP) with pH, redox or combined pH/temperature electrodes complete with SICRAM module
• conductivity, resistivity in liquids, total dissolved solids (TDS), and salinity with combined 4-ring and 2-ring conductivity and temperature probes with SICRAM module.
• Concentration of dissolved oxygen in liquids (in mg/l), saturation index (in %)