Code: Delta Ohm HD2402
Description
HD2402 is a portable photo-radiometer data logger for the measurement of noncoherent optical radiation in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
The instrument consists of a series of sensors to cover different portions of the spectrum and a small laser which is used to indicate the analyzed source.
The various sensors operate in the following spectral fields:
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.
The HD2402 can be powered either by connecting it to a PC, receiving power directly from the USB port of your PC, or via an external power supply with USB output (code SWD05). The CP24 connection cable is fitted with a M12 connector
on the instrument side and an USB type A connector on the PC side or to the power supply SWD05.
Using the software DeltaLog13 from version 1.0.1.0 and a PC, the HD2402 can be configured (calendar, date, time, start and duration of logging), and you can download and analyze the stored data or acquire the real-time data. Once configured, the data logger can be disconnected from the PC and connected to its power supply for capturing and storing data according to the programmed settings.
Complete with: DeltaLog13 software (version 1.0.1.0) to download, monitor and process the data on personal computer,
hardware key CH20 to enable the software, CP24 cable, power supply SWD05, manual, carrying case.
More products SENSECA
|
LUXMETER RADIOMETER MEASURING ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2302.0 HD2302.0VP474
• Device for measuring illuminance, luminance, PAR, irradiance |
|
SOUND LEVEL CALIBRATOR WITH AUDIO SIGNAL GENERATOR FOR ACOUSTIC CALIBRATIONS CLASS I/II DELTA OHM HD9101 HD9102
• generator noise level 9101/HD HD 9102 |
|
ANEMOMETER-THERMOMETER DELTA OHM HD2103.1 HD2103.2
• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module. |
|
THERMOPILE PYRANOMETER FOR MEASURE INCOMING GLOBAL SOLAR RADIATION DELTA OHM LP PYRA02 PYRA03 PYRA12
• First class pyranometer according to ISO 9060. |
|
AIR QUALITY ANALYSIS MONITORING DATALOGGER CO CO2 DELTA OHM HD37AB17D HD37B17D
• data loggers able to measure and memorize simultaneously the following parameters: |
|
PORTABLE PHOTO-RADIOMETER DATALOGGER TO MEASURE NON-COHERENT OPTICAL RADIATION ACC.EUROPEAN DIRECTIVE 2006/25/EC DELTA OHM HD2402
• portable photo-radiometer data logger for the measurement of noncoherent optical radiation |
|
PORTABLE PH-METER WITH THERMOMETER DELTA OHM HD2305.0
• pHmeter-Thermometer which measures pH, mV and temperature. |
|
MONO-AXIAL ACCELEROMETER AND TRIAXIAL ACCELEROMETER ICP MECHANICAL VIBRATIONS DELTA OHM
• HD356A02: tri-axial accelerometer for the measurement of vibrations transmitted to the handarm system |
|
CENTESIMAL THERMOMETER DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2
• Centesimal thermometer in the range +/-199.99°C, decimal outside this range |
|
DISSOLVED OXIGEN TESTER WITH THERMOMETER AND DATALOGGING DELTA OHM HD2109.1 HD2109.2
• Oxygen meter-Thermometer measures dissolved oxygen, saturation index and temperature. |