Manometers-Thermometers Delta Ohm HD2114 HD2134 HD2164

Code: Delta Ohm HD2114.0 HD2114.2 HD2134.0 HD2134.2 HD2164.0 HD2164.2 HD2114B.0 HD2114B.2


 

Datasheet PDF, 0.35 Mb
   

Description

These are portable instruments with a large LCD display. They measure absolute, relative and differential pressure, as well as temperature.
Pressure is measured using an internal module which is differential with respect to the atmosphere with fixed full scale. With the PP471 module acting as an interface, the instrument can use all the TP704 and TP705 series Delta Ohm probes to perform the measurements. The HD2114B.0 and HD2114B.2 internal module measures the barometric pressure.
The temperature is detected using immersion, penetration, contact or air probes, with SICRAM module or direct 4 wire probes. The sensor can be a Pt100 or Pt1000. Temperature probes are equipped with SICRAM module and factory calibration data are stored inside so that when the instrument is on it soon recognizes them.

 

The HD2114.2, HD2134.2, HD2164.2 and HD2114B.2 instruments are dataloggers. They store up to 36,000 samples which can be transferred in to a PC via the multi-standard RS232C serial port and USB 2.0. The storing interval, printing, and baud rate can be configured using the menu. They are also fitted with an RS232C serial port and can transfer the acquired measurements to a PC or to a portable printer in real time.
The Max, Min and Avg function calculates the maximum, minimum or average values. The Peak function can be activated with external probes connected to the module PP471 and detects the presence of pressure peaks. Other functions include: the relative measurement REL, the HOLD function, and the automatic turning off.

 

More products SENSECA

NET RADIOMETER WITH 4-COMPONENTS FOR SOLAR RADIATION MEASUREMENTS DELTA OHM LP NET14

• LP NET 14 is a 4-component net-radiometer for the measurement of the net radiation between 0.3µm and 45 µm.
• consists of two pyranometers: one for the measurement of the global radiation Esw? and the other one for the measurement of the reflected solar radiation Esw?
• pair of pyrgeometers: one for the measurement of the infrared radiation emitted by the sky EFIR? and the other one for the infrared emitted by the ground surface EFIR?
• equipped with a temperature sensor (NTC).

 

CENTESIMAL THERMOMETER DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2

• Centesimal thermometer in the range +/-199.99°C, decimal outside this range
• one input for Pt100 probes with SICRAM module measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power

 

LUXMETER RADIOMETER MEASURING ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2302.0 HD2302.0VP474

• Device for measuring illuminance, luminance, PAR, irradiance
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

PLUVIOMETER RAIN GAUGE FOR ATMOSFERIC PRECIPITATION DELTA OHM HD2013

• Rain gauge with tipping bucket,
• area 400cm2,
• for temperature range +4°C... +60°C.
• Standard resolution 0.2.
• On request at the time of placing the order resolution 0.1 or 0.5mm.
• Output contact normally closed.

 

PORTABLE PH-METER WITH THERMOMETER AND DATALOGGING DELTA OHM HD2105.1 HD2105.2

• pHmeter-Thermometer which measures pH, mV and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 34,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

LUXMETER PHOTO- RADIOMETER MEASURING SOLAR ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2102.1 HD2102.2

• Device for measuring illuminance, luminance, PAR, irradiance.
• Storage of maximum, minimum, average value and the integral Q(t),
• RS232 C output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

DATALOOGER WITH MICROCLIMATE ANALYSIS WBGT DELTA OHM HD32.2 HD32.2A

• analysis of WBGT index (Wet Bulb Glob Temperature: wet bulb temperature and globe thermometer temperature) in presence or in absence of solar radiation
• Logging
• data transfer speed via the RS232 serial port
• The measurement unit of the temperature: °C, °F, °K
• Date and time of the instrument
• display of maximum, minimum, medium statistic parameters and their deletion

 

LABORATORY BENCHTOP CONDUCTIVITY-METER-THERMOMETER WITH LIQUID RESISTIVITY, DISSOLVED SOLIDS TDS DELTA OHM HD3406.2

• Bench-top Conductivity meter-Thermometer measures conductivity, liquid resistivity,
• total dissolved solids (TDS) and salinity by 2 or 4 electrodes,
• combined conductivity probes and temperature by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value, it can store up to 36,000 samples.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled.,
• protection degree IP 66

 

LABORATORY TESTER FOR ELECTROCHEMICAL PARAMETERS: PH, CONDUCTIVITY, DISSOLVED OXYGEN, TEMPERATURE, CONCENTRATION, SOLIDS, SALINITY DELTA OHM HD22569.2

• bench top instrument for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature.
• It is are fitted with a large backlighted LCD display.
• pH, mV, redox potential (ORP) with pH, redox electrodes or electrodes with separate reference;
• conductivity, resistivity in liquids,
• total dissolved solids (TDS) and salinity with combined 4-ring and 2-ring conductivity/
• temperature probes with direct input or SICRAM module;
• concentration of dissolved oxygen in liquids (in mg/l) and saturation index (in %),

 

ANEMOMETER-THERMOMETER DELTA OHM HD2103.1 HD2103.2

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.
• RS232C/USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP67 protection degree.