Secondary Clsss Pyranometer according to WMO standard ISO9060 Delta Ohm LP PYRA08

Code: Delta Ohm LP PYRA08


 

Datasheet PDF, 0.84 Mb

Description

Second class pyranometer according to ISO 9060,
fast response sensor complete with calibration report,
possibility to replace the exhausted silica-gel.
Different configurations available.
Male M12 connector.
On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.
 

More products SENSECA

AIR QUALITY ANALYSIS MONITORING DATALOGGER CO CO2 DELTA OHM HD37AB17D HD37B17D

• data loggers able to measure and memorize simultaneously the following parameters:
• Relative Humidity RH
• Environment temperature T
• Carbon monoxide CO (only HD37AB17D)
• Carbon dioxide CO2
• DeltaLog13 communication software via the USB port

 

8-16 CHANNEL TEMPERATURE DATALOGGER DELTA OHM HD32.7 HD32.8.8 HD32.8.16

• HD32.7 - 8 INPUTS DATA LOGGER FOR pt100 SENSOR PROBES
• HD32.8.8/ HD32.8.16 Rugged data logger with 8/16 inputs for K, J, T, N, R, S, B and E type thermocouple with miniature connector temperature probes
• Unit of measurement °C, °F, °K configurable.
• Data logging: instantaneous or postponed, with the possibility of selecting the storage start and end.
• Data download: RS232C, 1200...38400 baud or USB 1.1 - 2.0.
• DeltaLog9 software for data download and processing.

 

SOUND LEVEL CALIBRATOR FOR MICROPHONES AND ACOUSTIC STATIONS DELTA OHM HD2020

• HD 2020 sound level calibrator
• portable, battery operated sound source
• suitable for sound level meters (portable and laboratory) and acoustic stations
• class 1 according to IEC60942:2003 with LCD display.
• ISO 9001 calibration report included.
• 1000Hz frequency allows calibrating sound level meters with any weighting

 

INDOOR QUALITY ANALYSIS IAQ MONITORING DATALOGGER CO CO2 DELTA OHM HD37AB1347

• Datalogger for indoor air quality analysis (IAQ)
• measures: airspeed, temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide)
• Memory capacity of 67,600 records for each of the two inputs.
• Logging interval from 15 seconds to 1 hour.

 

MULTIPARAMETRIC PH-METER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD2156.1 HD2156.2

• pHmeter-Conductivity-Thermometer measures pH, mV, conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Datalogger, stores the maximum, minimum, average value and can store up to 20,000 sets of three measurements.
• USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

LOGGING INSTRUMENT FOR CO, CO2, ATMOSPHERIC PRESSURE, TEMPERATURE, HUMIDITY DELTA OHM HD21AB HD21AB17

• Carbon Dioxide CO2
• Carbon Monoxide CO
• Atmospheric Pressure
• Temperature
• Relative Humidity
• Dew Point, Wet Bulb Temperature, Absolute Humidity, Mixing Ratio, Enthalpy

 

MANOMETER-THERMOMETER DIGITAL HANDHELD DELTA OHM HD2124.1 HD2124.2

• Manometer-Thermometer with two inputs for SICRAM module PP471 to connect probes TP704 and TP705 series.
• Temperature measurement with Pt100 probe complete with SICRAM module measuring range 200°C +650°C.
• Datalogger which stores the maximum, minimum, average value and can store up to 32,000 couples of samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD, PEAK and auto power off which can be disabled,
• IP 67 protection degree.

 

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD2256.2

• Bench-top pHmeter-Conductivity meter-Thermometer with back-lighted display,
• to measure pH, mV, ORP by pH, redox, separated reference electrodes, one input for a pH/temperature combined probe,
• it measures conductivity, liquid resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes with
• 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger for pH or mV, conductivity or resistivity or TDS and temperature.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.

 

SOUND LEVEL CALIBRATOR WITH AUDIO SIGNAL GENERATOR FOR ACOUSTIC CALIBRATIONS CLASS I/II DELTA OHM HD9101 HD9102

• generator noise level 9101/HD HD 9102
• portable, battery-powered sound source,
• suitable for calibration of sound level meters (portable and laboratory) and acoustic measuring stations
• possible to calibrate directly microphones 1 / 2 "of mechanical dimensions conform to the requirements of IEC 61094-1
• the frequency of the sound signal at 1000Hz can perform calibration of sound level meters with any frequency weighting
• sound pressure level generated is independent of atmospheric pressure
• Ease of use allows the use even by unskilled personnel.

 

PHOTOMETRIC PROBE FOR OUTDOOR MEASURING OF SOLAR ILLUMINANCE DELTA OHM LP PHOT02

• Outdoor photometric probe for measuring ILLUMINANCE (0...150 Klux),
• CIE photopic filter,
• diffuser for cosine correction.
• mVdc output for klux.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors.