Seba KMT T26/1 T26/1A T26/1B T26/1C High Voltage Cable Testing

Code: Seba-KMT T26/1 T26/1A T26/1B T26/1C


 

Datasheet PDF, 0.56 Mb

Description

T 26/1

The T 26/1A and T 26/1B high-voltage test sets are efficient, mobile systems for high-voltage testing of cables, cable systems and installations as required by current regulations (VDE) with DC voltages of up to 400 kV and 650 kV respectively. The sets are suitable for both installation in measuring trailers and onsite testing as stationary test set. The spatial separation of the operating and high-voltage units makes it possible to operate the sets from outside the immediate danger area. Their modular structure makes them easy to set up on site and allows adaptation to measuring tasks. 

The sets are primarily designed for power supply companies, cable laying firms and cable manufacturers for the DC voltage testing of high-voltage systems and cables. Their short-circuit-proof output circuit and high power make them suitable for use in fault location as a burn-down unit for burning high-impedance and intermittent cable fault. 

Key benefits:

  • Great mobility
  • Simple, safe operation
  • Thermal overload shutdown
  • Discharge switch

 

 

 

Standard accessories

 

 

Recommended options

 

 

More products SEBAKMT

SEBA KMT HPG 70-K 70KV DC HIGH VOLTAGE HIPOT TESTER

• fully insulated test set for DC testing up to 70 kV
• Testing of cables, switchgear, current-transformers, MV plant/ component testing,
• Highest safety thanks to fully insulated design
• Compact and lightweight
• Separate control and HV-unit
• Voltage continuously adjustable
• Expandable with a VLF CR attachment for VLF testing on MV cables

 

SEBA BPS 5000-D BURN AND PROOF TEST SYSTEM ON MEDIUM VOLTAGE CABLES BPS-5000D BPS500D BPS 5000D-VLF

• Easy-go single button operation
• Protocolling of the test results
• Data transfer via Bluetooth
• DC burn current up to 6 A
• AC burn current up to 110 A
• Sheath fault pinpoiting mode

 

SEBA SURGEFLEX SFX 8-1000 CABLE FAULT LOCATING SYSTEM

• Small, light and portable
• Very low voltage levels
• Complete fault location with DC Testing up to 8 kV
• Prelocation with ARM and ICE
• Burning with up to 1.4 A

 

SEBA KMT ESG NT PINPOINTING EARTH FAULT LOCATOR IN SHEATH OF UNDERGROUND CABLES

• high accuracy pinpointing of a sheath fault
• Automatic adaptation to voltage level
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• High-contrast color display

 

SEBA KMT VFL CR-20 VERY LOW FREQUENCY CABLE TESTING SYSTEM

• VLF Test System 20 kV
• high test capacity of 3 µF permits the simultaneous testing of all three phases
• method is officially recommended by the two VDE Standards 0276-620 and 0276-621
• VLF is the most economic method for testing PE and XLPE cables

 

SEBAKMT CORRELUX C-3 HYBRID LEAK NOISE CORRELATOR, ONLINE AND OFFLINE

• Precise leak detection
• State-of-the-art sensor technology
• Online and offline correlation
• Simple operation
• Robust design

 

SEBA SMART THUMP 16 CABLE FAULT LOCATION SYSTEM ON LOW AND MEDIUM VOLTAGE CABLES

• 1500J at 8 / 16 kV, 16 kV DC-HV proof test 23/46mA Burning
• Integrated ARM and ICE Prelocation
• Easy Go - automatic sequence to proof test, pre-locate & pinpoint
• Automatic interpretation of test results
• Sunlight readable, transflective 5.7" TFT colour display
• Safe OP Check protects user from incorrect or faulty lead connections
• USB interface for trace export via USB flash drive

 

SEBA KMT BT 500 IS-1 CABLE FAULT CONVERTER

• Overload protection
• Automatic discharge
• Burning of high resistive faults
• Low- potential free voltage avoids damage to other conductors
• Adjustable current limiter

 

SEBA KMT HPA35 HPA50 HPA58 HPA78 AC HIGH VOLTAGE HIPOT TESTING WITHSTANDING

• HPA 35, AC testing up to 35 kVrms
• HPA 50 / 58 AC testing up to 50 / 58 kVrms
• HPA 78, AC testing up to 78 kVrms

 

SEBA FAULT SNIFFER FOR DETECTION OF BURNING GASES FROM FAULT CABLES UNDERGROUND

• Customers can stay connected
• Fault location with no supply interrupt
• Reliable avoidance of incorrect excavations
• Fast and easy location of faults
• Can be used on straight or branched networks
• Handy size, easy to transport
• No pre-location required
• Accuracy in the decimetre range
• Sensitive to several specifi c gases and therefore suitable for any insulation material