Seba KMT TAN DELTA Cable condition Diagnosis System

Code: Seba-KMT TAN-DELTA


 

Datasheet PDF, 0.3 Mb
   

Description

Tan Delta

The tan delta test attachment enables a precise determination of the condition of the cable. Integral aging effects, such as the degree of humidity and "water treeing" can be simply recognised and quantified, making the tan delta test attachment the ideal instrument for monitoring the condition of the cable.

The tan delta test attachment can be used as a stand-alone system with the portable VLF sine systems from SebaKMT or in combination with the integrated VLF sine test systems in test vehicles.

The system achieves very accurate measurements because it measures at the high voltage potential and the measuring head can be placed very close to the test object.

Key Benefits:

  • Very accurate measurement
  • Optional leakage current correction
  • High wireless range
  • Measurement at high voltage potential
  • Light and portable

 

 

Standard accessories

 

 

Recommended options

Options

Leakage current correction

 

More products SEBAKMT

SEBA KMT T22/13B BURN UNIT FOR TESTING MEDIUM VOLTAGE CABLES T22-13B

• Short circuit proof
• Equipped with new circuity to keep Burn-Down power constant
• Maximal Burn-Down current of 25A
• Burn-Down voltage constinuously variable from 0 to 15 kV
• Indication of output current and voltage
• Integrated start interlock circuit and discharging device
• Pulse mode for earth leakage

 

SEBA KMT VFL CR-80 46KV HIGH VOLTAGE CABLE TEST SYSTEMS

• Powerful 0.1 Hz VLF test system
• High test power without frequency reduction
• No polarisation effects as by DC testing
• Protocoling
• Breakdown recognition
• Leakage current measurement

 

SEBA SURGEFLEX SFX 8-1000 CABLE FAULT LOCATING SYSTEM

• Small, light and portable
• Very low voltage levels
• Complete fault location with DC Testing up to 8 kV
• Prelocation with ARM and ICE
• Burning with up to 1.4 A

 

SEBA KMT BT 500 IS-1 CABLE FAULT CONVERTER

• Overload protection
• Automatic discharge
• Burning of high resistive faults
• Low- potential free voltage avoids damage to other conductors
• Adjustable current limiter

 

SEBA KMT HPA 100 AC HPA 130 DC BURNDOWN HIGH VOLTAGE TESTING

• Powerful test- and burning system
• Continuous testing with AC voltages up to 100 kVrms at 5 kVA
• Own noise-level below 1 pC
• Built-in overcurrent protection
• DC testing up to 130 kV with optional rectifier

 

SEBA DIGIPHONE+ ESG NT PINPOINTING ACOUSTIC PINPOINTING SET FOR STEATH FAULT LOCATION IN UNDERGROUND CABLES

• Perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• Acoustic and step voltage fault location in one device
• BNR technology for perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic setting of all parameters, no adjustments necessary

 

SEBAKMT CORRELUX C-3 HYBRID LEAK NOISE CORRELATOR, ONLINE AND OFFLINE

• Precise leak detection
• State-of-the-art sensor technology
• Online and offline correlation
• Simple operation
• Robust design

 

SEBA KMT VFL SINUS 34KV 0.1HZ SINE WAVE CABLE TEST SYSTEMS

• High test capacity of 5 µF
• Suitable for outdoor use (IP 54)
• Single-button operation easyGO
• Integrated safety system
• Reporting
• Continuous duty cycle

 

SEBA KMT LPD MONITOR ON-LINE PD PARTIAL DISCHARGE MONITORING SYSTEM FOR MV AND HV

• Portable online PD measuring system for monitoring MV and HV systems
•  16 channels
•  Allows ef? cient forward planning of necessary maintenance work
•  Quick and easy to install
•  Integrated automatic knowledge-based evaluation of measured PD levels
•  Current status can be viewed at any time via remote access

 

SEBA TELEFLEX VX CABLE REFLECTOMETER FOR FAULT LOCATION SYSTEMS

• Range : 20 m … 1280 km
• Bright and large display
• Easiest operation via self guiding and explaining menus
• ARM Slide Technology
• Automatic storage of all results
• Supports all existing prelocation technologies
• Automatic detection and display of cable end and fault position