Seba KMT T99/1 40kV DC High Voltage Test Unit

Code: Seba-KMT T99/1


 

Datasheet PDF, 0.3 Mb

Description

T 99-1

The high voltage test unit T99/1 is a portable and powerful test device able to generate a DC voltage of up to 40 kV. The T 99/1 is used for testing of cables, cable accessories, plant and installations. Because of the short-circuit proof design and high output current of the T 99/1, this is device is also suitable for cable fault location (in conjunction with a TDR unit). 

Key benefits:

  • Ideal for field application because of its low weight and compact design
  • High safety due to internal discharge facility
  • High flexibility with the external battery
  • Over-current tripping
 

Standard accessories

Scope of Delivery

 T 99/1 Test Set 40 kV

 Connecting leads

 Operation manual

 

 

Recommended options

Optional Accessories

 Battery connecting cable 10 m, 2 x 4 mm2, including battery clip

 Accessory bag

 Safety resistor < 70 kV

 

 

More products SEBAKMT

SEBA KMT T22/13B BURN UNIT FOR TESTING MEDIUM VOLTAGE CABLES T22-13B

• Short circuit proof
• Equipped with new circuity to keep Burn-Down power constant
• Maximal Burn-Down current of 25A
• Burn-Down voltage constinuously variable from 0 to 15 kV
• Indication of output current and voltage
• Integrated start interlock circuit and discharging device
• Pulse mode for earth leakage

 

SEBA KMT VCAM-5 SEWER PIPELINE VIDEO INSPECTION CAMERA

• One touch recording
• Lightweight and compact design
• Records to USB, SD or HDD
• JPEG still image capture
• Wi-Fi and Ethernet interface

 

SEBA KMT VFL CR-80 46KV HIGH VOLTAGE CABLE TEST SYSTEMS

• Powerful 0.1 Hz VLF test system
• High test power without frequency reduction
• No polarisation effects as by DC testing
• Protocoling
• Breakdown recognition
• Leakage current measurement

 

SEBA SMART THUMP 16 CABLE FAULT LOCATION SYSTEM ON LOW AND MEDIUM VOLTAGE CABLES

• 1500J at 8 / 16 kV, 16 kV DC-HV proof test 23/46mA Burning
• Integrated ARM and ICE Prelocation
• Easy Go - automatic sequence to proof test, pre-locate & pinpoint
• Automatic interpretation of test results
• Sunlight readable, transflective 5.7" TFT colour display
• Safe OP Check protects user from incorrect or faulty lead connections
• USB interface for trace export via USB flash drive

 

SEBA SURGEFLEX SFX-15 SFX-25 CABLE FAULT LOCATING SYSTEM

• » DC-Testing up to 15 kV / 25 kV (depending on model)
• » Prelocating
• » - Reflection measurement
• » - ARM-Measurement (Arc reflection method)
• » - ICE Impulse current method
• » Cable tracing (optional)
• » Pin-pointing
• » - Distance and acoustic measurement
• » - Audio frequency methods (optional)
• » Battery and mains operation

 

SEBA KMT VLOCML2 PIPELINE LOCATION AND TRACING FOR UNDERGROUND PIPES AND CABLES

• Location of passive markers which are used by utility
• companies for labelling underground lines
• Colour-coded display of the signal strength
• Specifi c line location mode
• Specifi c marker location mode
• Mode for simultaneous location of lines and markers

 

SEBA KMT HPA35 HPA50 HPA58 HPA78 AC HIGH VOLTAGE HIPOT TESTING WITHSTANDING

• HPA 35, AC testing up to 35 kVrms
• HPA 50 / 58 AC testing up to 50 / 58 kVrms
• HPA 78, AC testing up to 78 kVrms

 

SEBA KMT LPD MONITOR ON-LINE PD PARTIAL DISCHARGE MONITORING SYSTEM FOR MV AND HV

• Portable online PD measuring system for monitoring MV and HV systems
•  16 channels
•  Allows ef? cient forward planning of necessary maintenance work
•  Quick and easy to install
•  Integrated automatic knowledge-based evaluation of measured PD levels
•  Current status can be viewed at any time via remote access

 

SEBA BPS 5000-D BURN AND PROOF TEST SYSTEM ON MEDIUM VOLTAGE CABLES BPS-5000D BPS500D BPS 5000D-VLF

• Easy-go single button operation
• Protocolling of the test results
• Data transfer via Bluetooth
• DC burn current up to 6 A
• AC burn current up to 110 A
• Sheath fault pinpoiting mode

 

SEBA KMT MMG 10 CABLE SHEATH TESTER

• Adjustable current limiter
• Easy and powerful testing of cable jackets
• Pulsed output voltage for sheath fault pinpointing
• Burning of cable faults