Seba KMT PVS-100 Phase Identification Tester for Cable Selection

Code: Seba-KMT PVS-100


 

Datasheet PDF, 1.13 Mb
 

Description

PVS 100

The exact knowledge of the phase assignment in the area of power distribution is an essential requirement for the safe and reliable power network operation. This covers all voltage levels from a low voltage distribution to high voltage transmission systems. A phase identification or verification is required for the determination of load distribution, the control of the phase assignment of old or new installation and prior to switching to avoid damages and outages. The phase identification with the PVS 100 enhances the safety of power distribution systems and prevents accidents.

Key benefits:

  • Clear determination of the phase assignment in respect to a reference phase
  • Determination of the phase by GPS synchronisation and GSM connection
  • Offline measurement without data connection by post synchronisation possible
  • Easy entry and correction of transformer vector groups
  • Reliable function in all voltage levels
  • Easiest operation

 

 

  • Identifies the phase at all voltage levels in real time
  • Functions with and without a permanent data connection
  • Easy to operate
  • Eliminates safety risks
  • Saves time and money

 

All the advantages at a glance

Direct phase indication with a GSM/GPS connection or with an available low voltage connection

Extremely easy input of phase shifts/vector groups by using the zero key

Can operate independently of GSM or GPS reception with synchronisation

of the stored readings

Internal memory for 10 days of continuous operation

Li-Ion battery for 10 hours of operation

Data transfer via USB

Operation via LCD touch screen

Intuitive operating software

High voltage sensor with bidirectional wireless transmission to PVS 100

and direct visual signalling

 

 

 

 

Standard accessories

Phase verification system,

full set

»» 2 x PVS 100 incl. GPS outdoor unit

»» High voltage sensor with probe tips

»» Insulating rod 110 kV

»» 2 x cable set

»» Tripod for GPS module with holder

»» PVS probe for capacitive taps

»» Charger for HVS 120-36 and PVS probe

»» 2 GSM aerials with holder

»» 2 cases/trolleys for PVS 100

Phase verification system,

additional device

»» 1 x PVS 100 incl. GPS outdoor unit

»» High voltage sensor with probe tips

»» I nsulating rod 110 kV

»» Cable set

»» Tripod for GPS module with holder

»» PVS probe for capacitive taps

»» Charger for HVS 120-36 and PVS probe

»» GSM aerial with holder

»» 1 case/trolley for PVS 100

 

 

Recommended options

 

 

More products SEBAKMT

SEBA SWG 505 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG505

• Voltage Ranges : 0.. 3kV / 4kV / 5kV
• Energy : 180J / 320J / 500J
• MAx Current Imax : 129mA / 182mA / 213mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method

 

SEBA KMT VLOC-5000 LINE LOCATION AND TRACER FOR UNDERGROUND PIPES AND CABLES

• Precise direction guidance with right/left arrows and guidance compass
• SiS ("Signal Select") and SD ("Signal Direction") for reliable line identification
• "Distortion Alert" for signal evaluation
• Internal GPS receiver and data storage
• Permanent depth or signal current intensity measurement

 

SEBA KMT PD SURVEYOR AIR PARTIAL DISCHARGE DETECTOR FOR MEDIUM VOLTAGE CABLES, SWITCHGEAR, PLANTS

• Three PD sensor technologies in one device
•  Early detection of PD activity
•  Universal application - can be applied to
• MV cables, MV switchgear & other types of MV plants
•  Directs maintenance resources straight to the problem areas
•  Easy to use

 

SEBA KMT T26/1 T26/1A T26/1B T26/1C HIGH VOLTAGE CABLE TESTING

• DC voltages of up to 400 kV and 650 kV
• Great mobility
• Simple, safe operation
• Thermal overload shutdown
• Discharge switch

 

SEBA KMT VM-810 LOCATION UNDERGROUND PIPES AND CABLES

• Easy to use
• High location accuracy
• Optimal inductive transmission of line signals
• Signal "jumps over" insulating pipe sleeves

 

SEBA DIGIFLEX COM REFLECTOMETER FAULT LOCATING ON METALLIC TELECOMM LINES, COAXIAL AND POWER CABLES

• Measuring range from 5 m up to 30 km
• Line comparison with 2 measuring inputs
• High resolution in the near and far range
• Weatherproof case
• Solid housing for rugged fi eld use

 

SEBA BPS 5000-D BURN AND PROOF TEST SYSTEM ON MEDIUM VOLTAGE CABLES BPS-5000D BPS500D BPS 5000D-VLF

• Easy-go single button operation
• Protocolling of the test results
• Data transfer via Bluetooth
• DC burn current up to 6 A
• AC burn current up to 110 A
• Sheath fault pinpoiting mode

 

SEBA KMT T22/13B BURN UNIT FOR TESTING MEDIUM VOLTAGE CABLES T22-13B

• Short circuit proof
• Equipped with new circuity to keep Burn-Down power constant
• Maximal Burn-Down current of 25A
• Burn-Down voltage constinuously variable from 0 to 15 kV
• Indication of output current and voltage
• Integrated start interlock circuit and discharging device
• Pulse mode for earth leakage

 

SEBA KMT HPG 50..80-D DC & AC HIGH VOLTAGE CABLE TESTER

• HPG 50-D, AC testing up to 35 kVRMS/ DC testing up to 100 kV
• HPG 70 / 80-D, AC testing up to 50 / 58 kVRMS / DC testing up to 140 / 150 kV
• Suitable for AC testing and DC testing
• Compact, cast-resin high-voltage transformers
• Separate control and HV-units
• Voltage continuously adjustable
• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation

 

SEBA KMT FERROLUX FLE 10 AUDIO FREQUENCY RECEIVER FOR CABLE LOCATION, SELECTION, SHEATH FAULTS

• Precise direction guidance with right/left arrows
• "SignalSelect" for clear route location
• Depth and signal current intensity measurement at the push of a button
• Route sensor weighs less than 1 kg for non-tiring use
• "DirectSignal" for effective line location