Seba KMT PIL 8 Phasenlux Phase identi?cation in earthed and short-circuited medium voltage cables

Code: Seba-KMT PIL-8 Phasenlux


 

Datasheet , 0.33 Mb

Description

Pil 8

The Phase identification System PIL 8 permits a fast and especially safe phase determination at the jointing location during the mounting of medium voltage cables. 

According to DIN VDE 0105 0100 part 2 (EN 50110-1) from Okt. 1997, Pos. 6.2.4.1 Topic 3 (Page 12) it specifies 

"... If the earthing or shorting has to be removed for the duration of measurements or tests, suitable other safety measures have to be taken." 

Such safety measures require a relatively large effort and are not always practical. The specific advantage of the technology used in the PIL 8 is the fact, that the ground or shorting must not be removed. In opposition, this grounding it is an essential part of the procedure, which means, the cable must be grounded and shorted for the system to work. Resulting the use is absolutely safe. For each phase the according transceiver clamp are installed tot he grounded cable end and then at the selection point each phase is identified and marked. 

Key benefits:

  • Maintenance free transceiver clamps
  • Suitable for any type of switch gear
  • Requires only one person
  • Easiest operation
  • Absolute safe phase identification

 

 

Standard accessories

Scope of delivery

1 pc. Generator/receiver PIL 8

1 set of Cables VL 83-E

3 pairs of Transceiver tongs PIZ 50

1 pc. Transport case PIK 8

 

Special accessories

for each additional end-to-end measurement (3 are

possible) 3 pairs of transceiver tongs PIZ50

 

Recommended options

 

 

More products SEBAKMT

SEBA KMT VFL CR-60-HP LONG CABLES TEST SYSTEMS

• Very high test power without frequency reduction
• Covers cables up to 20 km @ maximum Voltage
• No polarisation effects as with DC
• Protocoling
• Breakdown detection
• Leakage current measurement
• Powerful 0.1 Hz VLF test system with energy recovery

 

SEBA TELEFLEX LV MONITOR CABLE FAULT LOCATION SYSTEM WITH MONITORING MEGGER

• Fault location on live low voltage cables
• 3 phase cable monitor for a permanent check of current and voltage
• GSM remote controlled system

 

SEBAKMT CORRELUX C-3 HYBRID LEAK NOISE CORRELATOR, ONLINE AND OFFLINE

• Precise leak detection
• State-of-the-art sensor technology
• Online and offline correlation
• Simple operation
• Robust design

 

SEBA KMT EASYTEST 20KV VFL CABLE TESTER VERY LOW FREQUENCY

• simplified version of the standard VLF test
• Easy to operate
• Configurable test sequences
• Compact, rugged and lightweight design
• AC, DC and sheath testing in one single system
• Reporting via USB or Winkis

 

SEBA SWG 1750 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG1750 SWG1750C SWG1750CI SWG1750C-4 SWG1750CD

• Voltage Ranges : 0.. 8kV / 0..16kV / 0..32kV
• SWG 1750C with 8 - 16 - 32 kV / 1750 J
• SWG 1750 CI with 8 - 16 - 32 kV / 1750 J, incl. leakage current measurement
• SWG 1750 C-4 with 2 - 4 kV / 1150 J and 8 - 16 - 32 kV / 1750 J
• SWG 1750 CD with 8 - 16 - 32 kV / 3500 J

 

SEBA KMT PIL 8 PHASENLUX PHASE IDENTI?CATION IN EARTHED AND SHORT-CIRCUITED MEDIUM VOLTAGE CABLES

• Maintenance free transceiver clamps
• Suitable for any type of switch gear
• Requires only one person
• Easiest operation
• Absolute safe phase identification


SEBA KMT T26/1 T26/1A T26/1B T26/1C HIGH VOLTAGE CABLE TESTING

• DC voltages of up to 400 kV and 650 kV
• Great mobility
• Simple, safe operation
• Thermal overload shutdown
• Discharge switch

 

SEBA TELEFLEX SX CABLE REFLECTOMETER FOR FAULT LOCATION MEGGER

• ARMslide technology with 15 traces in one ARM shot
• ProRange for optimised display of distant details
• Support of all existing prelocation technologies
• Automatic adjustment and display of cable end and fault
• Compatible with all fault location systems

 

SEBA SURGEFLEX SFX-32 SPG-32 CABLE FAULT LOCATING SYSTEM

• »» DC-testing up to 32 kV
• »» Prelocating
• - Reflection measurement
• - ARM measurement
• (Arc Reflection Method) up to 32 kV
• - Decay up to 32 kV
• - ICE Impulse Current Method
• 0…4 / 8 / 16 / 32 kV
• »» Burning (fault conditioning) up to 32 kV
• »» Cable tracing (optional)
• »» Pinpointing
• - Distance and acoustic measurement
• 0 … 8 / 16 / 32 kV at 1750 J

 

SEBA KMT EZ-THUMP CABLE FAULT LOCATION SYSTEM ON LV/MV CABLES

• Easiest, fully automatic operation
• All in one small and portable unit
• ARM Prelocation
• Pinpointing with 500 J
• Available as 4 or 12 kV version
• Bright, brilliant colour display
• Battery operation