Code: Seba-KMT PIL-8 Phasenlux
Description
Pil 8
The Phase identification System PIL 8 permits a fast and especially safe phase determination at the jointing location during the mounting of medium voltage cables.
According to DIN VDE 0105 0100 part 2 (EN 50110-1) from Okt. 1997, Pos. 6.2.4.1 Topic 3 (Page 12) it specifies :
"... If the earthing or shorting has to be removed for the duration of measurements or tests, suitable other safety measures have to be taken."
Such safety measures require a relatively large effort and are not always practical. The specific advantage of the technology used in the PIL 8 is the fact, that the ground or shorting must not be removed. In opposition, this grounding it is an essential part of the procedure, which means, the cable must be grounded and shorted for the system to work. Resulting the use is absolutely safe. For each phase the according transceiver clamp are installed tot he grounded cable end and then at the selection point each phase is identified and marked.
Key benefits:
Standard accessories
Scope of delivery
1 pc. Generator/receiver PIL 8
1 set of Cables VL 83-E
3 pairs of Transceiver tongs PIZ 50
1 pc. Transport case PIK 8
Special accessories
for each additional end-to-end measurement (3 are
possible) 3 pairs of transceiver tongs PIZ50
Recommended options
More products SEBAKMT
|
SEBA KMT TAN DELTA CABLE CONDITION DIAGNOSIS SYSTEM
• Very accurate measurement |
|
SEBA BPS 5000-D BURN AND PROOF TEST SYSTEM ON MEDIUM VOLTAGE CABLES BPS-5000D BPS500D BPS 5000D-VLF
• Easy-go single button operation |
|
SEBA KMT VIVAX METROTECH VLOC2 LINE LOCATION AND TRACER FOR UNDERGROUND PIPES AND CABLES
• Carbon-reinforced plastic housing |
|
SEBA KMT PIL 8 PHASENLUX PHASE IDENTI?CATION IN EARTHED AND SHORT-CIRCUITED MEDIUM VOLTAGE CABLES
• Maintenance free transceiver clamps |
|
SEBA KMT HPG 70-K 70KV DC HIGH VOLTAGE HIPOT TESTER
• fully insulated test set for DC testing up to 70 kV |
|
SEBA SMART THUMP 16 CABLE FAULT LOCATION SYSTEM ON LOW AND MEDIUM VOLTAGE CABLES
• 1500J at 8 / 16 kV, 16 kV DC-HV proof test 23/46mA Burning |
|
SEBA DIGIPHONE+ SURGE WAVE RECEIVER FOR ACOUSTIC AND ELECTROMAGNETIC FAULT PINPOINTING IN CABLES
• Perfect acoustic quality and noise immunity |
|
SEBA SFX 5-1000 SPG 5-1000 CABLE FAULT LOCATION SYSTEM ON LOW AND MEDIUM VOLTAGE CABLES
• ICEplus for the easy and reliable fault prelocation without interference from branches |
|
SEBA KMT EZ-THUMP CABLE FAULT LOCATION SYSTEM ON LV/MV CABLES
• Easiest, fully automatic operation |
|
SEBA SURGEFLEX SFX-40 SPG-40 CABLE FAULT LOCATING SYSTEM
• DC Testing up to 40 kV ARM, ICE and Decay Method integrated |