Code: Seba-KMT PIL-8 Phasenlux
Description
Pil 8
The Phase identification System PIL 8 permits a fast and especially safe phase determination at the jointing location during the mounting of medium voltage cables.
According to DIN VDE 0105 0100 part 2 (EN 50110-1) from Okt. 1997, Pos. 6.2.4.1 Topic 3 (Page 12) it specifies :
"... If the earthing or shorting has to be removed for the duration of measurements or tests, suitable other safety measures have to be taken."
Such safety measures require a relatively large effort and are not always practical. The specific advantage of the technology used in the PIL 8 is the fact, that the ground or shorting must not be removed. In opposition, this grounding it is an essential part of the procedure, which means, the cable must be grounded and shorted for the system to work. Resulting the use is absolutely safe. For each phase the according transceiver clamp are installed tot he grounded cable end and then at the selection point each phase is identified and marked.
Key benefits:
Standard accessories
Scope of delivery
1 pc. Generator/receiver PIL 8
1 set of Cables VL 83-E
3 pairs of Transceiver tongs PIZ 50
1 pc. Transport case PIK 8
Special accessories
for each additional end-to-end measurement (3 are
possible) 3 pairs of transceiver tongs PIZ50
Recommended options
More products SEBAKMT
|
SEBA KMT VFL CR-60-HP LONG CABLES TEST SYSTEMS
• Very high test power without frequency reduction |
|
SEBA TELEFLEX LV MONITOR CABLE FAULT LOCATION SYSTEM WITH MONITORING MEGGER
• Fault location on live low voltage cables |
|
SEBAKMT CORRELUX C-3 HYBRID LEAK NOISE CORRELATOR, ONLINE AND OFFLINE
• Precise leak detection
|
|
SEBA KMT EASYTEST 20KV VFL CABLE TESTER VERY LOW FREQUENCY
• simplified version of the standard VLF test |
|
SEBA SWG 1750 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG1750 SWG1750C SWG1750CI SWG1750C-4 SWG1750CD
• Voltage Ranges : 0.. 8kV / 0..16kV / 0..32kV |
|
SEBA KMT PIL 8 PHASENLUX PHASE IDENTI?CATION IN EARTHED AND SHORT-CIRCUITED MEDIUM VOLTAGE CABLES
• Maintenance free transceiver clamps |
|
SEBA KMT T26/1 T26/1A T26/1B T26/1C HIGH VOLTAGE CABLE TESTING
• DC voltages of up to 400 kV and 650 kV |
|
SEBA TELEFLEX SX CABLE REFLECTOMETER FOR FAULT LOCATION MEGGER
• ARMslide technology with 15 traces in one ARM shot |
|
SEBA SURGEFLEX SFX-32 SPG-32 CABLE FAULT LOCATING SYSTEM
• »» DC-testing up to 32 kV |
|
SEBA KMT EZ-THUMP CABLE FAULT LOCATION SYSTEM ON LV/MV CABLES
• Easiest, fully automatic operation |