Karl Fischer Moisture In Oil Test Sets Megger ½ KF875 and KF-LAB MkII

Code: Megger KF875 KF-LAB MkII


 

Datasheet PDF, 0.22 Mb

Description

Over 20 years experience has led to the development of the Megger KF875 and KF-LAB MkII Coulometric Karl Fischer Test Sets designed to determine moisture in oil, to provide highly accurate results on-site. The KF875 and KF-LAB MkII are highly portable instruments, complete with integral printer and carrying case, are easy to use and provide highly accurate results.

 

Optimized for testing insulating oils with a specific gravity of 0.875, the Megger KF875 simply requires the operator to press one button and inject a 1ml sample into the test cell. The simple ½one touch½ operation makes the KF875 so easy to use that it requires no specialist knowledge or training to use it effectively. Results are presented on the instrument display and on the integral printer in both micrograms of water and in milligrams per kilogram (parts per million, ppm).

 

The KF-LAB MkII allows the titration of samples with a range of specific gravities from 0.60 to 1.40 and also permits the use of different sample sizes. The KF-LAB MkII also has a default setting optimized for analyzing insulating oils with an SG of 0.875. This means it can be used to measure water content in a variety of different materials but is also easy to set up for transformer insulating oils.

 

Features:

  • Coulometric Karl Fischer titrimetry
  • KF875 optimized for insulating oil with an SG of 0.875, completely portable
  • KF-LAB MkII offers greater flexibility, versatility and sample data input than the KF875; also completely portable
  • KF-LAB MkII analyzes materials with an SG between 0.6 & 1.4, plus insulating oils with an SG of 0.875
 

More products MEGGER

MEGGER MIT515/2 5KV INSULATION RESISTANCE MEGOHMMETER

• RE>Act mode enhanced accuracy and safety
• PI predictor function (PIp)
• Measures up to 20 TΩ
• Up to 3 mA noise rejection

 

MEGGER FREJA 300 PROGRAMMA RELAY TESTER CF-19091

• can generate 4x150 V (82 VA) and 3x15 A (87 VA) or 1x45 A (250 VA).
• Manual and automatic control
• Easy to use
• Excellent software provides great visuals and simple setup
• Lightweight and portable
• Highly accurate
• User can calibrate unit

 

PRIMARY CURRENT INJECTION TEST SYSTEM MEGGER ODEN AT

• Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
• Modular design to permit optimal user configuration of output current vs. unit size
• Compact transport cart facilitates portability into switchgear rooms with limited space
• Unique I/30 function allows the current to be pre-set using low current to prevent test sample heating, thus eliminating corruption of test result

 

EARTH LEAKAGE CLAMPMETER MEGGER - DCM300E

• 0.01 mA resolution
• EMC and IEC61010-2-032 compliance
• 30 mA, 300 mA, 30 A and 300 A range

 

MEGGER IMT100 MULTIFUNCTION INDUSTRIAL TESTER FOR PHOTOVOLTAIC INSTALLATIONS

• Powerful 3-in-1 tester for safe, accurate PV installation
• Exceptionally safe to use
• Complete suite of insulation resistance
• Ready for outdoor conditions

 

MEGGER MIT2500 2.5KV INSULATION TESTER

• Insulation testing up to 2.5 kV and 200 GΩ range in a handheld instrument
• Guard terminal for high resistance accuracy
• Adjustable insulation test voltage from 50 V to 2500 V
• Stabilised insulation test voltage

 

MEGGER TM1800 CIRCUIT BREAKER ANALYZER CG-19290 CG-19292 CG-19294 CG-19296

• Modular based design - user configurable TM1800 from nine different modules
• Built in PC with CABA Local software - advanced testing with predefined breaker test plans (templates), onsite measurement view and analysis
• Dual ground testing using DCM module - increased safety with both sides of breaker grounded
• Fast and easy testing - Select-Connect-Inspect workflow and high level user interface
• Graphical results for quick interpretation - timing and motion measurements, coil currents
• USB and Ethernet communication interface - for quick back up, LAN connection and printer options
• CABA Win - for advanced data analysis, database interface and common test data archive

 

MEGGER TM1700 CIRCUIT BREAKER ANALYZER TM1710 TM1720 TM1740 TM1750 TM1760

• Provides reliable and accurate test results in noisy high voltage substations
• Four standard models. Full stand-alone functionality or data acquisition models without user interface.
• Fast and safer with DualGround™ testing, both sides of breaker grounded
• On-screen assistance with connection diagrams and test template Wizard
• All models can be controlled via computer

 

MEGGER MPRT2145 SINGLE PHASE RELAY TESTER

• Open communication architecture for third party software application
• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power (60 amps/400 VA rms)
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

COMBINED LOOP AND RCD TESTERS MEGGER - LRCD210 AND LRCD220

• Non-trip loop tester
• RCD testing from 10 mA to 1000 mA
• Extremely easy and safe to use
• Built-in protective front cover