MEGGER MFT1800 MFT1825 MFT1815 Universal electrician installation tester

Code: MFT1800 MFT1825 MFT1815 1002-402 1002-403 1002-405 1002-407 1002-408 1002-410


 

Datasheet PDF, 0.45 Mb

Description

MFT1800 Series
Multifunction installation testers MFT1815, MFT1825

About the product
  • Type-B RCD and three-phase RCD testing for industrial applications with no earth/ground
  • Two-wire and three-wire non-trip loop testing for RCD protected circuits
  • Choice of 3-pole, 3-pole with attached rod technique, 2-pole and stakeless tests for earth electrode resistance measurement
  • Simple colour-coded test selection and large clear backlit display for ease of use
  • Auto reversing continuity test of a choice of 200 mA and 15 mA test currents
  • Internal memory and Bluetooth communications
  • EN61010 CATIV safety ratings and tough IP54 case

The MFT1800 series of multifunction installation testers have been designed for testing low voltage electrical installations to the requirements of all IEC 60364 derived standards. They provide all the tests required to complete the necessary electrical certification for industrial, commercial, and domestic fixed wiring installations.

The series is comprised of 3 instruments:

MFT1815 - The entry level tester offering CAT IV safety, 200 mA continuity, two-wire non trip loop testing with resistance and fault current display, frequency measurement and the largest, brightest, and clearest display on the market.
MFT1825 - The most popular of the range of testers offering all the benefits of the MFT1815, plus three-pole and two-pole earth electrode testing, 15 mA continuity testing, auto RCD testing, phase rotation, programmable and three-phase RCD testing, and current measurement with the optional clamp.

 

All instruments are IEC 61010 CAT IV 300 V rated for connection to low voltage systems with no protective device, so can be safly connected anywhere on the system up to the source transformer without risk of damage from large transient spikes.

Visible and audible safety warnings are paramount when testing high energy systems, and the MFT1800 range includes full input protection and safety warnings when a hazardous voltage is present. If live voltages exist on a circuit during insulation or continuity testing, the voltage is displayed on the screen. If this voltage exceeds a safe level, further testing is inhibited and a warning sounds.

Quick to pick up and use, the rotary controls are colour-coded to make range selection easy and fast, also reducing the chance of using the wrong function or range. Additionally, the large clear backlit display uses the patented Megger digital/analogue arc, providing you with indication of fluctuating readings while the dual digital readout shows precise values of key measurements simultaneously with the test parameters, such as the output voltage on insulation testing as well as the resistance value in MΩ.

 

Due to circumstances beyond our control, Megger has to obsolete certain models from its MFT1800 series. However, this action allows us to focus our efforts on developing new products that better meet your needs and incorporate the latest technologies. The MFT-X1 is our latest product in the multifunction family and can directly replace the obsoleted MFT1800 series instruments and offers more advanced electrical test capability. The MFT1815 and MFT1825 are not affected by this obsolescence and are still available for purchase.

Models affected by the obsoletion:

MFT1835 variants
MFT1845+ variants
Models not affected by the obsoletion:

MFT1815 variants
MFT1825 variants

Youtube video presentation of MEGGER MFT1800



 

Standard accessories

Description Order Code
MFT1815-AU 1005-270
MFT1815-CH-DE/FR 1002-402
MFT1815-SC-DE/NL/EN 1002-403
MFT1815-SC-FR/ES 1002-405
MFT1825-AU 1002-406
MFT1825-CH-DE/FR 1002-407
MFT1825-SC-DE/NL/EN 1002-408
MFT1825-SC-FR/ES 1002-410
Description Order Code
Included accessories
Printed quickstart guide
Calibration certificate
Switched probe SP5 1007-157
Neck strap - Megger embroidered 2001-509
3 Wire lead set with prods and clips 1001-991
Euro mains test lead SIA45 (not AU) 2000-674
AU/NZ plug test lead (AU only) 6220-828


 

Recommended options

Optional accessories
Soft carry case with lead/document pouch 6420-143
Fused 10 A test lead set (red/blue/green)
with prods and clips 1001-975
ETL30 Extension Test Lead 30 m 1000-215
ETL50 Extension Test Lead 50 m 1000-217
Battery charging lead 12V 1004‐183
Earth electrode kit 1001-810
ETK30 (3 Pole Earth Test Kit) 1010-176
MCC1010 Current measuring clamp 1010-516
MVC1010 Voltage clamp 1010-518

 

More products MEGGER

MEGGER EGIL BREAKER ANALYZER BM-19090 BM-19093 BM-19095

• Suitable for testing timing and travel on all circuit breakers with single interrupter per phase
• Extremely easy-to-use and reliable
• Two separate timing channels for measurement of auxiliary contacts
• Analog measurement channels for travel transducers or general voltage/current measurements
• Static and dynamic resistance measurements along with the SDRM201 accessory

 

MEGGER CDAX-605 CAPACITANCE AND DISSIPATION FACTOR MEASUREMENT INSTRUMENT CDAX605 AI-19090

• capacitance and dissipation factor test
• High accuracy and wide measurement range
• Automatic measurement process
• Measures capacitive, resistive or inductive test objects
• High accuracy ratio measurements
• Works with any standard capacitor or resistor value without any recalculations
• All standard UST and GST configurations

 

MEGGER MIT1025/2 10KV INSULATING RESISTANCE MEGOMETER

• Diagnostic testing with full test suite
• PI Predictor™ cuts test time in half
• Accurate testing with RE>Act™
• Built-in storage and easy data export
• Designed for safe testing in the field

 

MEGGER S1-1068/2 EXPERT 10KV INSULATION RESISTANCE MEGOHMMETER

• Reliable results in noisy substations
• Accurate testing with RE>Act™
• Remote control for safer, easier testing
• PI Predictor™ cuts test time in half
• Full diagnostic suite with PDC capability

 

MEGGER SMRT36 THREE PHASE RELAY TESTER

• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power (60 Amps/300 VA rms) per phase
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS Software

 

MEGGER MIT480/2 MIT481/2 MIT485/2 INSULATION TESTER FOR COMMUNICATIONS 500V

• Insulation testing up to 500 V and 100 GΩ range in a hand held instrument
• 3-wire connection for A, B, and E (Tip, Ring and Ground/Earth) connection
• Gated access to 500 V to prevent accidental damage
• CAT IV 600 V and IP 54

 

VACUUM INTERRUPTER TESTER MEGGER - VIDAR

• Tests the integrity of vacuum interrupters quickly, safely and easily
• User defined voltage selection
• Extensive voltage range
• Easy to operate. Follows ANSI/IEEE standardized DC test methods.
• Lightweight and portable

 

MEGGER TTRU1 TRANSFORMER TURN RATIO TESTER

• Battery operated with USB-C rechargeablenAA NiMH batteries included
• Pass/Fail ratio evaluation
• Automatic results storage
• USB drive save and export
• Full colour Hi-bright LCD screen
• Additive / Subtractive polarity detection
• Excitation current

 

MEGGER FREJA 306 PROGRAMMA RELAY TESTER CF-29091

• current outputs, higher amps (3 x 15 A + 3 x 35 A), VA or compliance voltage.
• test differential relays with 6 currents, or virtually any single or 3-phase relay
• For secondary testing of protection relays
• Can be used stand-alone or with a PC
• Flexble, can test many relay types
• Lightweight and portable
• Greatest possible precision

 

MEGGER FREJA 400 PROGRAMMA RELAY TEST SYSTEM FREJA400

• FREJA 403 3x60 A at 300 VA per phase.
• FREJA 406 Up to 6 channels: 3 x 60 A and 3 x 15 A
• FREJA 409 Up to 9 channels: 6 x 60 A and 3 x 15 A
• Voltage outputs : Up to four channels 300 V at 150 VA
• Fully automated testing using FREJA Win software
• PC operated or stand alone using the intuitive graphic touch screen
• High current, high power output (60 A / 300 VArms) per phase
• FREJA 409 provides 3 x 120 A in threephase configuration mode
• FREJA 406 provides 6 currents, and FREJA 409 provides 9 currents for transformer differential testing
• IEC 61850 test capabilities