Type-B RCD and three-phase RCD testing for industrial applications with no earth/ground
Two-wire and three-wire non-trip loop testing for RCD protected circuits
Choice of 3-pole, 3-pole with attached rod technique, 2-pole and stakeless tests for earth electrode resistance measurement
Simple colour-coded test selection and large clear backlit display for ease of use
Auto reversing continuity test of a choice of 200 mA and 15 mA test currents
Internal memory and Bluetooth communications
EN61010 CATIV safety ratings and tough IP54 case
The MFT1800 series of multifunction installation testers have been designed for testing low voltage electrical installations to the requirements of all IEC 60364 derived standards. They provide all the tests required to complete the necessary electrical certification for industrial, commercial, and domestic fixed wiring installations.
The series is comprised of 3 instruments:
MFT1815 - The entry level tester offering CAT IV safety, 200 mA continuity, two-wire non trip loop testing with resistance and fault current display, frequency measurement and the largest, brightest, and clearest display on the market.
MFT1825 - The most popular of the range of testers offering all the benefits of the MFT1815, plus three-pole and two-pole earth electrode testing, 15 mA continuity testing, auto RCD testing, phase rotation, programmable and three-phase RCD testing, and current measurement with the optional clamp.
All instruments are IEC 61010 CAT IV 300 V rated for connection to low voltage systems with no protective device, so can be safly connected anywhere on the system up to the source transformer without risk of damage from large transient spikes.
Visible and audible safety warnings are paramount when testing high energy systems, and the MFT1800 range includes full input protection and safety warnings when a hazardous voltage is present. If live voltages exist on a circuit during insulation or continuity testing, the voltage is displayed on the screen. If this voltage exceeds a safe level, further testing is inhibited and a warning sounds.
Quick to pick up and use, the rotary controls are colour-coded to make range selection easy and fast, also reducing the chance of using the wrong function or range. Additionally, the large clear backlit display uses the patented Megger digital/analogue arc, providing you with indication of fluctuating readings while the dual digital readout shows precise values of key measurements simultaneously with the test parameters, such as the output voltage on insulation testing as well as the resistance value in MΩ.
Due to circumstances beyond our control, Megger has to obsolete certain models from its MFT1800 series. However, this action allows us to focus our efforts on developing new products that better meet your needs and incorporate the latest technologies. The MFT-X1 is our latest product in the multifunction family and can directly replace the obsoleted MFT1800 series instruments and offers more advanced electrical test capability. The MFT1815 and MFT1825 are not affected by this obsolescence and are still available for purchase.
• Interchangeable test lead terminations
• High or low output power selection for condition diagnosis
• Operates from battery or AC mains supply
• Protected to 600 V without blowing a fuse, test lead live voltage warning light
• Powerful 3-in-1 tester for safe, accurate PV installation
• Exceptionally safe to use
• Complete suite of insulation resistance
• Ready for outdoor conditions
• Powered off of phase A voltage AC/DC
• Weatherproof to IP54 standard for use in any environment
• 1000 VAC and 1500 VDC range
• Auto CT identifies the current that the instrument is connected to and the range that it is in
• Real time scope and DVM
• IEC61000-4-30 Class A compliance
• 200.0 A a.c. open-jaw current measurement
• 0.1 V to 1000 V auto-ranging a.c. and d.c. voltage measurement
• 0.1 O to 20.00 MO resistance range
• Continuity buzzer
• High test current
• Four terminal measurement
• Two measuring ranges (2000 mO. and 20,00 mO.)and maximum resolution of 0,01 mO.
• Protected against inadvertent connection to the mains supply
• FREJA 403 3x60 A at 300 VA per phase. • FREJA 406 Up to 6 channels: 3 x 60 A and 3 x 15 A • FREJA 409 Up to 9 channels: 6 x 60 A and 3 x 15 A • Voltage outputs : Up to four channels 300 V at 150 VA • Fully automated testing using FREJA Win software • PC operated or stand alone using the intuitive graphic touch screen • High current, high power output (60 A / 300 VArms) per phase • FREJA 409 provides 3 x 120 A in threephase configuration mode • FREJA 406 provides 6 currents, and FREJA 409 provides 9 currents for transformer differential testing • IEC 61850 test capabilities
• Test voltages : 60 kV, 80 kV and 100 kV • Laboratory instruments for measuring insulating oil breakdown voltage • Lock in precision - oil vessel with lockable adjustment • Bright 3.5" colour display • Suitable for mineral, ester and silicon oils • Trip detection circuit with direct measurement of voltage and current • Ultra fast (< 10 µs) HV switch off time