Battery Ground Fault Locator Megger - BGL

Code: Megger - BGL


 

Datasheet PDF, 0.18 Mb

Description

This instrument was developed to detect, track and locate ground faults on battery systems - without resorting to sectionalizing! Model BGL tracks and locates ground faults on live or dead battery systems. To save hours of unnecessary troubleshooting, the BGL readily differentiates between the resistive fault currents and capacitive charging currents. This feature allows the instrument to detect and track leakage paths, even in the presence of surge-suppression capacitors.

 

Features:

  • Ground faults in ungrounded dc battery systems easily located
  • Operates in high electrical noise environment
  • Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes
 

More products MEGGER

AC VOLTAGE DETECTORS MEGGER - VF3

• Non-contact detection of AC voltage
• Automatic audible warning buzzer
• Bright red voltage indicator in tip
• Ultra bright LED torch

 

MEGGER SVERKER 750 780 PROGRAMMA SINGLE PHASE RELAY TESTER

• The engineer’s toolbox for all single phase relay testing!
• Stand-alone functionality
• Rugged and reliable for field use

 

PRIMARY CURRENT INJECTION TEST SYSTEM MEGGER INGVAR

• Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
• Up to 5000 A output current
• Two units, each of about 20 kg, makes it easier to carry
• Unique I/30 function allows the current to be pre-set using low current to prevent test sample heating, thus eliminating corruption of test result

 

MEGGER DET3TC DET3TD EARTH RESISTANCE TESTER

• 2 and 3 point testing
• ART (Attached Rod Technique) testing capability with DET3TC
• Choice of digital or analog display
• Warning indicators prevent test failure
• IP54 rated
• Complete with leads, stakes and rugged carry case
• Simple one button operation
• Calibration test certificate included

 

MEGGER TRAX MULTIFUNCTION TRANSFORMER TEST SET FOR CAPACITANCE AND DISSIPATION POWER FACTOR

• Replaces the need for multiple test sets
• Powerful, portable and compact system
• Reduces user training and testing time
• Extend the life of power transformers
• 1 Hz insulation condition testing
• Manage and analyse test data

 

MEGGER MTO300 MTO330 TRANSFORMER SIX-WINDING OHMMETER MTO3XX

• Automated 8-terminal/6-winding measurement capability
• Simultaneous winding magnetization
• Tests operation of on-load tap-changers
• Built-in auto-demagnetization feature
• Automatic discharge
• Power DB software (MTO330)

 

MEGGER BGFT 246100B BATTERY GROUND FAULT TRACER

• Ground faults in ungrounded dc battery systems easily located
• Operates in high electrical noise environment
• Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes

 

COMBINED LOOP AND RCD TESTERS MEGGER - LRCD210 AND LRCD220

• Non-trip loop tester
• RCD testing from 10 mA to 1000 mA
• Extremely easy and safe to use
• Built-in protective front cover

 

EARTH LEAKAGE CLAMPMETER MEGGER - DCM300E

• 0.01 mA resolution
• EMC and IEC61010-2-032 compliance
• 30 mA, 300 mA, 30 A and 300 A range

 

FORK MULTIMETER MEGGER - DCM330

• 200.0 A a.c. open-jaw current measurement
• 0.1 V to 1000 V auto-ranging a.c. and d.c. voltage measurement
• 0.1 O to 20.00 MO resistance range
• Continuity buzzer