THT80 Compact Infrared thermography camera 120x90pxl

Code: THT80


 

HT Infrared Cameras PDF, 7.48 Mb

Description

THT80
Compact infrared camera with 120x90pxl resolution

THT80 is the new compact professional thermal camera equipped with a high resolution 120x90pxl IR sensor, a measuring range of -20°C ÷ 550°C and a field of view of 50° x 37° which makes it suitable for use in frequent hydraulic, mechanical or electrical maintenance.
It is also equipped with the AutoFusion function and a large color display with high brightness capacitive touch-screen, for immediate use, as well as being usable through the new and convenient HT Pro Camera application.

Functions
IR Resolution120 x 90 pxl
Temperature range-20° ÷ 550°C
Image frequency50Hz
Thermal sensitivity / NETD<0.05°C @ 30°C / 50mK
Field of view (FOV)50° x 37°
Focal lengthf 1.13
Lens2.3mm
IFOV7.3mrad
Focus modefixed focus
Built-in camera2 MP, foco fijo, con linterna LED
Picture in Picture function
AutoFusion image enhancement
Uncertainty about the measure±2°C (±3.6°F) o±2% of reading
Digital zoom1x ÷ 32x
Measurement tools (in live mode)3 spots, central spot, hot / cold spot, 3 areas, horizontal vertical lines
Area measurement informationmax, min, center
IR Video recording
Measurement correctionsemissivity, reflected temperature, ambient temperature, atmospheric humidity, infrared compensation, distance compensation
Color Palettesiron, rainbow, white hot, black hot, brown hot, blue/red, hot/cold, feather, above max alarm, below min alarm, interval alarm
Span modesAutomatic / Manual / Histogram
Built in LED light
Internal memory3,4 GB
On-camera report buildingtextual notes
Communication modesUSB tipo C, Wi-fi, micro SD
Displaytouch screen
Battery operation time3 hours
Size (LxWxH) (mm)133 x 87 x 24mm

 

More products HT ITALIA

INFRARED NON CONTACT THERMOMETER HT ITALIA

• Infrared temperature measurement from -50°C to 1000 °C
• Emissivity regulation
• Distance / Spot ratio of 50:1
• Laser pointer activation

 

HT2055 STEP AND CONTACT METER UP TO 50A

• TRMS
• Measuring range 200Ω
• Earth resistance by 2- and 3-wire method
• Ground resistivity by 4-wire method
• Compensation of disturbance voltages
• Compensation of test cables
• Measurement of step/contact voltage

 

HT9025T CURRENT CLAMP METER WITH INFRARD CAMERA AND 1500V DC

• TRMS
• Current measuring range 1000A
• AC/DC current AC+DC
• AC/DC voltage 1000VAC/1500VDC
• IR Resolution 120 x 120 pxl

 

SINGLE/ THREE-PHASE NETWORK AC VOLTAGE DATA LOGGER HT ITALIA XL423/ XL424

• TRMS AC Voltage measure up to 600V
• Recording with sampling programmable period
• Manual activation of recording
• RS-232 interface
• Programming with DATALINK software

 

SINGLE/ THREE-PHASE NETWORK AC CURRENT DATA LOGGER HT ITALIA XL421/ XL422

• TRMS AC current measure up to 2500A
• Recording with sampling programmable period
• Manual activation of recording
• RS-232 interface
• Programming with DATALINK software

 

DIGITAL MULTIFUNCTION VDE MULTIMETER HT ITALIA M74

• ContiDC Voltage
• AC TRMS Voltage
• nuity test of protective conductors with 200mA
• Insulation Resistance with 250, 500VDC
• Trip-out time of RCDs type AC Standard
• Test current selectable; 30mA, 30x5mA, 100mA, 300mA
• Global Earth Resistance without RCD tripping
• Global Earth Resistance with 0.1Ohm resolution

 

HT PQA924 CLASS S POWER QUALITY AND ENERGY ANALYZER

• AC voltage in single-phase and three-phase systems
• AC current in single-phase and three-phase systems
• Cosphi, Power Factor, K-Factor
• Voltage unbalance
• Flicker
• Active, Reactive, and Apparent power/energy
• Voltage and current harmonic amplitude and phase up to the 63rd order with THD% calculation

 

EARTH RESISTANCE AND LOOP IMPEDANCE RCD TESTER HT ITALIA SPEED 418

• Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
• Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
• Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
• Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
• Optical/USB interface for connection to PC

 

THREE-PHASE POWER QUALITY ANALYZER HT PQA820

• 3 system types: Single-phase, three-phase 3-wire, three-phase 4-wire.
•  Configurable directly from Smartphone or Tablet.
•  Fast trips and detailed zoom of all sizes.
•  Real Time.
•  Energy consumption logger.
•  383 parameters can be displayed simultaneously.
•  Technology and absolute simplicity.
•  Harmonics Jump function.

 

I-V600 ADVANCED MULTIFUNCTION INSTRUMENT FOR I-V CURVE MEASUREMENTS UP TO 1500V AND 40A

• I-V curve tracing of mono-facial and bi-facial PV modules and strings up to 1500V/40A according to IEC/EN60891
• SOLAR03 remote unit with Bluetooth connection
• Up to 3 reference cells to measure front-side and rear-side radiation according to IEC TS 60904-1-2
• Database of over 30,000 photovoltaic modules manageable via connection with the new HT AGORÀ software (downloadable in the Download Area)