Professional Multimeter Cable Verifier for LAN VDE checking HT Italia M75

Code: HT Italia M75


 

Datasheet PDF, 0.42 Mb

Description

DMM SECTION

  • DC Voltage
  • AC TRMS Voltage
  • AC TRMS Current with External Clamp
  • AC TRMS Leakage current with external clamp (optional)
  • DC Current
  • Resistance
  • Continuity test with buzzer
  • Frequency with test leads
  • Frequency with External Clamp
  • MIN/MAX/AVG functions
  • PEAK function with response time 1ms
  • HOLD function

 

SAFETY TEST SECTION

  • Continuity test of protective conductors with 200mA
  • Insulation Resistance measurement with 500VDC
  • Trip-out time of RCDs type AC Standard with test current of 30mA, 30x5mA, 100mA, 300mA
  • Global Earth Resistance without RCD tripping
  • Phase sequence indication at 1 or 2 wires
  • Phase coincidence indication at 1 or 2 wires
  • Leakage current (with HT96U optional clamp + NOCANBA connector)
  • AUTOTEST function: automatic sequence test of Global Earth Resistance + RDC test + Insulation test with OK / NOT OK indications LAN SECTION
  • Test executed on twisted pairs cables UTP and STP with RJ45 connector
  • Wire mapping control of following wrong conditions:
  • OPEN, SHORT, CROSS, REVERSE, SPLIT, MISWIRE message at display
  • Quickly selection of cables pairs
  • Automatic detection of remote control units (from #1 to #8)
  • AutoPowerOFF
  • Low battery indication
 

Standard accessories

  • HT4003: 400A AC clamps
  • C2075: two safety banana + Shuko plug cable
  • KIT0075: kit of 2 Test leads + 2 alligator clips
  • N° 2 Remote identifier # 1, # 2
  • N° 3 Patch cables, 30 cm, RJ45  RJ45 connectors
  • BORSA75: Carrying bag
  • Calibration Certificate ISO9000
  • Instruction manual
  • Warranty card
 

Recommended options

  • HT96U: leakage current clamp 1-100-1000A/1V 54mm max diameter
  • NOCANBA: adaptor for connection HT96U clamp
  • REM38: N° 6 Remote unit # 3, # 4, # 5, # 6, # 7, # 8
  • REM3: remote unit #3 + connection cable RJ45-RJ45
  • REM4: remote unit #4 + connection cable RJ45-RJ45
  • REM5: remote unit #5 + connection cable RJ45-RJ45
  • REM6: remote unit #6 + connection cable RJ45-RJ45
  • REM7: remote unit #7 + connection cable RJ45-RJ45
  • REM8: remote unit #8 + connection cable RJ45-RJ45
 

More products HT

MULTIFUNCTION PORTABLE MULTIMETER FOR EARTH RESISTANCE MEASUREMENT HT ITALIA M73

• Trip out time measure on AC Standard RCD's
• Trip out current: 30, 30x5, 100, 300mA
• Global Earth Resistance with 0.1Ohm resolution
• Global Earth Resistance without RCD's tripping
• DC Voltage
• AC TRMS Voltage
• Automatic detection of AC/DC signals

 

HANDHELD DIGITAL MEGOHMMETER INSULATION & CONTINUITY 4 GOHM 1000V HT ITALIA M70

• Insulation with test voltage 250, 500, 1000VDC
• Up to 4Gohm measurement range
• Automatic discharge of device under test
• LOCK feature for continuous measurements
• Programmable timer up to 60s
• Continuity of earth conductors with test current of 200mA
• A/DC voltage up to 600V
• Resistance and continuity test with buzzer

 

PROFESSIONAL MULTIMETER CABLE VERIFIER FOR LAN VDE CHECKING HT ITALIA M75

• DC Voltage
• AC TRMS Voltage
• Continuity test of protective conductors with 200mA
• Insulation Resistance measurement with 500VDC
• Global Earth Resistance without RCD tripping
• Test executed on twisted pairs cables UTP and STP with RJ45 connector
• Quickly selection of cables pairs

 

HANDHELD DIGITAL SOUNDMETER WITH CALIBRATOR HT ITALIA HT154

• Measure of Sound Level Pressure (SPL)
• 0.1dB resolution
• Selection manual of range
• MAX/MIN display
• Frequency Weighting A and C
• Integration FAST/SLOW

 

DIGITAL MULTIFUNCTION VDE MULTIMETER HT ITALIA M74

• ContiDC Voltage
• AC TRMS Voltage
• nuity test of protective conductors with 200mA
• Insulation Resistance with 250, 500VDC
• Trip-out time of RCDs type AC Standard
• Test current selectable; 30mA, 30x5mA, 100mA, 300mA
• Global Earth Resistance without RCD tripping
• Global Earth Resistance with 0.1Ohm resolution

 

EARTH RESISTANCE AND LOOP IMPEDANCE RCD TESTER HT ITALIA SPEED 418

• Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
• Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
• Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
• Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
• Optical/USB interface for connection to PC

 

HT SOLAR I-VE MULTIFUNCTION I-V CURVE TRACER FOR PHOTOVOLTAIC SYSTEMS

• 1500V Multifunction I-V Curve Tracer for maintenance and efficiency tests on single-phase installations.
• Measurement of efficiency of a single-phase photovoltaic system
• Measurement of I-V Curve of a module or of a string up to 1500V/10A - 1000V/15A
• Measurement of open-circuit voltage of a module or of a string (VOC) 1500V
• Measurement of short-circuit current of a module or of a string (ISC) 15A

 

PV-ISOTEST TESTER FOR CHECKING ELECTRIC SAFETY OF PHOTOVOLTAIC PANELS WITH GROUD FAULT LOCATION GFL FUNCTION

• Insulation measurement up to 1,500V DC even on live systems
• Localization of the faulty module through the new GFL function
• Continuity of the protective conductor with 200mA

 

DIGITAL PORTABLE MULTIMETERS HT ITALIA

• DC Voltage
• AC TRMS Voltage
• DC Current
• AC TRMS Current

 

HT PQA924 CLASS S POWER QUALITY AND ENERGY ANALYZER

• AC voltage in single-phase and three-phase systems
• AC current in single-phase and three-phase systems
• Cosphi, Power Factor, K-Factor
• Voltage unbalance
• Flicker
• Active, Reactive, and Apparent power/energy
• Voltage and current harmonic amplitude and phase up to the 63rd order with THD% calculation