Pressure Calibrator Fluke 718

Code: Fluke 718


 

Datasheet PDF, 0.54 Mb

Description

  • Pressure Source and Milliamp Measurement to calibrate and maintain almost any pressure device
  • Integrated pump is easily cleaned when accidently exposed to fluids that reduces cost of ownership and repairs and enables servicing the pump in the field
  • Error % calculation for quicker pass/fail decision making in the field
  • Best in class mA accuracy of 0.015 % for better measurement confidence and workload coverage
  • Min/Max/Hold to capture changing measurements
  • Switch test feature for quicker and more accurate pressure switch testing
  • New 1 and 300 PSI pressure ranges mean fewer extra tools required
  • 1, 30, 100 & 300 PSI ranges available
 

Standard accessories

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • Test Leads and Alligator Clip
  • Two 9V alkaline batteries
  • NIST - Traceable calibration report and data
 

Recommended options

Fluke 718 1G

Pressure Calibrator -1 to 1 PSI, (-689 mbar to 689 mbar, -689 to 689 kPa)

Fluke 718 30G

Pressure Calibrator -12 PSI to 30 PSI, (-850 mbar to 2 bar, -85 to 20684 kPa)

Fluke 718 100G

Pressure Calibrator -12 PSI to 100 PSI, (-850 mbar to 7 bar, -85 to 68948 kPa)

Fluke 718 300G

Pressure Calibrator -12 PSI to 300 PSI, (-850 mbar to 20 bar, -85 to 206842 kPa )

 

More products FLUKE

FLUKE 1621 EARTH GROUND TESTER

• 3-pole Fall-of-Potential earth testing for basic measurements
• 2-pole resistance measurements for added versatility
• 600 V Cat II

 

DIGITAL CONTACT THERMOMETERS SERIES FLUKE 50 II

• Relative time clock on MIN, MAX, and AVG provides a time reference for major events
• Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
• Measures J, K, T, and E-types of thermocouples
• Readout in ºC, ºF, or Kelvin (K)
• Data Logging up to 500 points of data with user adjustable recording interval(Fluke 53 II and Fluke 54 II)

 

AC VOLTAGE DATA ACQUISITION RECORDING KIT FLUKE FLK-CNX V3000 KIT

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC voltage measurements to 1000V
• Memory recording up to 65,000 readings
• CAT III 1000 V; CAT IV 600 V; IP42


FLUKE II905 ACOUSTIC CAMERA IMAGER FOR INSPECTINA AND DETECTION COMPESSED AIR

• Easy, fast, and safe visual detection of compressed gas leaks with LeakQ mode including estimated leak size and cost.
• The 7" LCD touchscreen overlays a SoundMap on visual images, facilitating rapid leak location identification.
• The integrated visual- and textual tagging and annotation functionalities offer important details to optimize reporting and follow-up actions.

 

FLUKE VT04 INFRARED THERMOMETER WITH INTEGRATED CAMERA

• take simultaneous visual images with the thermal heat map images that are accurately aligned close in
• Temperature measurement range -10 °C to +250 °C (14 °F to 482 °F)
• Infrared spectral band 6.5 µm to 14 µm
• Minimum focus distance 50 cm (19.6 in)
• Field of View 28° X 28°
• 4 GB Micro SD card

 

MULTI-PRODUCT UNIVERSAL CALIBRATOR FLUKE 5522A

• Handheld and bench meters (analog and digital) up to 6 ½ digits
• Current clamps and clamp meters, Thermocouples and RTDs
• Process calibrators, Data loggers
• Strip and chart recorders, Watt meters
• Power harmonics analyzers, Panel meters
• Graphical multimeters, Power quality analyzers (with option)

 

PHASE ROTATION INDICATOR FLUKE 9040

• 3 phase indication
• Indication of phase rotation
• Clear LCD display
• No battery required

 

HANDHELD LOOP CALIBRATOR FLUKE 707EX

• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.015%
• For use in explosion endangered areas ATEX certifed ( II 2 G Eex ia IIC T4)

 

INDUSTRIAL MAINTENANCE SYSTEM FLUKE CNX 3000 GM

• • True-RMS AC and DC voltage measurements to 1000V
• • True-RMS AC and DC current with 0.01 mA resolution
• • True-RMS AC voltage measurements to 1000V
• • True-RMS AC current measurements to 2500 A


FLUKE 1550C MEGOHMMETER INSULATION RESISTANCE 250V/ 5KV

• Resistance Test range: 1 TO
• Test voltage: 5 kV