  • Pressure Source and Milliamp Measurement to calibrate and maintain almost any pressure device
  • Integrated pump is easily cleaned when accidently exposed to fluids that reduces cost of ownership and repairs and enables servicing the pump in the field
  • Error % calculation for quicker pass/fail decision making in the field
  • Best in class mA accuracy of 0.015 % for better measurement confidence and workload coverage
  • Min/Max/Hold to capture changing measurements
  • Switch test feature for quicker and more accurate pressure switch testing
  • New 1 and 300 PSI pressure ranges mean fewer extra tools required
  • 1, 30, 100 & 300 PSI ranges available
 

Standard accessories

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • Test Leads and Alligator Clip
  • Two 9V alkaline batteries
  • NIST - Traceable calibration report and data
 

Recommended options

Fluke 718 1G

Pressure Calibrator -1 to 1 PSI, (-689 mbar to 689 mbar, -689 to 689 kPa)

Fluke 718 30G

Pressure Calibrator -12 PSI to 30 PSI, (-850 mbar to 2 bar, -85 to 20684 kPa)

Fluke 718 100G

Pressure Calibrator -12 PSI to 100 PSI, (-850 mbar to 7 bar, -85 to 68948 kPa)

Fluke 718 300G

Pressure Calibrator -12 PSI to 300 PSI, (-850 mbar to 20 bar, -85 to 206842 kPa )

 

More products FLUKE

FLUKE 1654B MULTIFUNCTION INSTALLATION TESTER 50V-1000V

• Test voltage: 50V, 100V, 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results
• Earth resistance

 

FLUKE 700PTPK PNEUMATIC TEST KIT FOR PRESSURE CALIBRATION

• Combine with any Fluke-700G Series Gauge, 1,000 psi (69 bar) or less, to make a complete pressure testing kit
• Generate pressure up to 600 psi, 40 bar with the 700PTP-1 test pump
• Connect the 700G Series gauge directly to the included PTP-1 hand pump
• Includes hoses and adapters for connecting to the pressure device to be tested
• Hard case protects pump and gauge and allows gauge to remain connected to the pump

 

INTERNAL BATTERY RESISTANCE ANALYZER FLUKE BT520

• Key measurements: Battery resistance, dc and ac voltage, dc and ac current, ripple voltage, frequency and battery temperature.
• Enhanced data analysis: Quickly compare trends, analyze results and create reports with included battery management software.
• Easy reporting: Generate PDF report on the PC software with analysis graphics and data table or quick email format report with csv file on the mobile app.
• Wireless communication
• USB Port

 

FLUKE NORMA 4000 PRECISION POWER ANALYZER

• 1 to 3 power phases
• Bandwidth from dc to 3 MHz / 10 MHz
• FFT analysis, vector diagram, and Digital Oscilloscope
• Voltage, current and power harmonics measured up to the 40th harmonic

 

HANDHELD VOLT/MA CALIBRATOR FLUKE 715

• 0 to 200 mV, 0 to 20 V Voltage measure
• 0 to 100mV, 0 to 10 V Voltage source / simulate
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• very high accuracy of 0.015% and 1 mA resolution

 

FLUKE 28 II HANDHELD MULTIMETER RUGGED IP67 INDUSTRIAL 4.5 DIGIT

• 4.5 digit
• 20,000 count resolution for precise measurements
• 0.05% basic accuracy
• New - IP 67 waterproof & dustproof protection, completely sealed for use in harsh environments
• Peak min-max
• True-rms ac voltage and current for accurate measurements on non linear signals
• Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument

 

VOLTAGE CONTINUITY TESTER FLUKE T140

• Resistance measurement
• Backlight
• LED Bargraph
• Display: 3½ digit LCD
• Voltage test
• Optical and acoustical continuity test

 

FLUKE 714B THERMOCOUPLE CALIBRATOR

• measure and simulate (17) different thermocouple types and millivolts
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration

 

AC VOLTAGE DATA ACQUISITION RECORDING KIT FLUKE FLK-CNX V3000 KIT

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC voltage measurements to 1000V
• Memory recording up to 65,000 readings
• CAT III 1000 V; CAT IV 600 V; IP42


FLUKE 434 II THREE PHASE POWER QUALITY ANALYZER

• Energy loss calculator
• Real-time analysis of trends using the cursors and zoom tools
• Highest safety rating in the industry
• Measure all three phases and neutral
• Automatic Trending
• Ten power quality parameters on one screen according to EN50160 power quality standard
• Logger function