Fluke 714B Thermocouple Calibrator

Code: Fluke 714B


 

Datasheet PDF, 1.87 Mb

Description

Highly accurate, easy-to-use single function thermocouple temperature calibrator

 For the temperature calibration professional who wants a highly accurate, easy-to-use, single function thermocouple temperature calibrator the Fluke 714B is the ideal test tool.

 

 

  • The 714B can measure and simulate (17) different thermocouple types and millivolts
  • Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
  • Hanging tool designed in and included with every unit
  • Configurable 0 % and 100 % source settings for quick 25 % linearity checks
  • Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
  • Dual inputs and backlit display for easy interpretation of measurements
  • Power down settings remembered at power up for easy restart of tests
  • 1-year and 2-year specifications and traceable certification of calibration
 

General Specifications

Maximum voltage applied between any terminal and earth ground or between any two terminals

30 V

Operating temperature

-10 °C to 50 °C

Storage temperature

-30 °C to 60 °C

Operating altitude

2,000 meters

Storage altitude

12,000 meters

Relative humidity (% RH operating without condensation)

Non condensing

90% (10 °C to 30 °C)

75% (30 °C to 40 °C)

45% (40 °C to 50 °C)

(Without condensation)

Vibration requirements

MIL-T-28800E, Class 2

Drop text requirements

1 meter

IP Rating

IEC 60529: IP52

Electromagnetic environment

IEC 61326-1, Portable

Safety

IEC 61010-1, Max 30 V to earth, Pollution Degree 2

Power supply

4 AA NEDA 1.5A IEC LR6 batteries

Size (H x W x L)

52.5 mm x 84 mm x 188.5 mm

Weight

515 g

 

Standard accessories

 

Included equipment

  • Magnetic hanging tool
  • batteries,
  • manual,
  • traceable calibration certificate,
  • test leads
 

More products FLUKE

CURRENT CLAMP METER TRUE-RMS AC/DC 200A FLUKE 365

• 200 A AC and DC current measurement with detachable jaw
• 600 V AC and DC voltage measurement
• True-rms AC voltage and current
• 6000 O resistance measurement

 

FLUKE 1625-2 GEO EARTH GROUND RESISTANCE TESTER

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• USB data storage and transfer
• Automatic Frequency Control (AFC)
• R* measurement - calculates earth ground impedance at 55 Hz

 

FLUKE 6306 AUTOMATIC RCL METER 50 HZ..1 MHZ

• 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps)
• 100 kHz to 1 MHz (1 kHz steps) test frequencies
• 0.1 % basic accuracy
• Easy to use, at-a-glance display

 

MILIAMP PROCESS CLAMP METER FLUKE 772

• 0 to 24 mA Current measure / source / simulate
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity

 

CURRENT CLAMP METER AC/DC TRUE-RMS 2000 A FLUKE 355

• 2000 A AC + DC true-rms, 1400 A AC, and 2000 A DC
• large 58 mm (2.3 in) jaw capacity
• 1000 V AC + DC true-rms, 600 V AC, and 1000 V DC
• Accurately measure frequency up to 1 kHz
• Resistance to 400 Kohms

 

LASER DISTANCE METER 100M FLUKE 424D

• The ultimate Fluke laser distance meter
• Measures up to 100 m (330 feet)
• Feature-rich meter includes tilt sensor for hard-to-reach measurements, corner angle feature and compass

 

PRESSURE CALIBRATOR FLUKE 717

• Measure pressure, 0.05% of full scale
• Measure mA with 0.015% accuracy and 0.001 mA resolution
• Measure pressure to 10,000 psi/700 bar

 

VOLTAGE CONTINUITY TESTER FLUKE T90/ T110/ T130/ T150

• Voltage AC/DC 12V - 690V
• Continuity 0 - 400 k?
• Frequency 0 / 40 - 400 Hz
• Phase rotation
• Resistance measurement

 

FLUKE TIS50 INFRARED CAMERA 220X165

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

AIR FLOW METER FLUKE 922

• Air Pressure
• Air Velocity
• Air Flow (Volume)
• Temperature