Handheld Volt/mA Calibrator Fluke 715

Code: Fluke 715


 

Datasheet PDF, 0.53 Mb

Description

  • 0 to 200 mV, 0 to 20 V Voltage measure
  • 0 to 100mV, 0 to 10 V Voltage source / simulate
  • 0 to 24 mA Current measure
  • 0 to 20 mA Current source / simulate
  • Measure loop current (0-20 mA, 4-20 mA) signals with very high accuracy of 0.015% and 1 mA resolution
  • Measure voltage output process signals from PLCs, transmitters
  • 24V loop supply with simultaneous current measurement
  • Enhanced voltage and current measure and source accuracy
  • Improved battery life
  • 250 ohm HART resistor with loop power
  • Holster features test lead storage
  • Compatible with toolpack magnetic hanging system
  • Step and linear ramp output function
  • Configurable zero and span settings
 

Standard accessories

  • Protective Yellow Holster with Test Lead Storage
  • Instructions Sheet (14 languages)
  • single 9V alkaline battery
  • Test Leads and Alligator Clips
  • NIST- traceable calibration report and data
 

More products FLUKE

FLUKE TI300 INFRARED CAMERA 240X180 RESOLUTION

• 240x180 Detector resolution
• Ruggedized high resolution 640x480 capacitive touch screen for quick menu navigation
• Range: -20 °C si +650 °C
• Precision : ± 2 °C sau 2%
• Sensibility : = 0,05 °C

 

MOTOR PHASE ROTATION INDICATOR FLUKE 9062

• 3 phase indication
• Indication of phase rotation
• Indication of motor rotation direction
• Contact free determination of the rotation direction of running motors

 

FLUKE 1625-2 GEO EARTH GROUND RESISTANCE TESTER

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• USB data storage and transfer
• Automatic Frequency Control (AFC)
• R* measurement - calculates earth ground impedance at 55 Hz

 

FLUKE 179 HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count resolution
• 0.09% basic accuracy
• True RMS voltage and current measurements
• Digital display with analog bargraph and backlight
• Temperature measurements

 

FLUKE 1630 EARTH GROUND CLAMP METER

• resistance range from 0.025 O to 1500 O
• large jaw opening of 35 mm
• ground leakage current, from 0.2 mA to 1000 mA
• ac current measurement range from 0.2 A to 30 A

 

MULTIFUNCTIONAL TESTER FOR TEMPERATURE, HUMIDITY, VELOCITY, CO, CO2 FLUKE 075 AIRMETER

• Temperature -20 °C to 50 °C (-5 °F to 122 °F)
• Velocity 0.25 m/sec to 15 m/sec
• Relative Humidity 10 % to 90 % RH, non-condensing
• CO2 0 to 5000 ppm
• CO 0 to 500 ppm

 

FLUKE 700HTPK HYDRAULICTEST KIT FOR PRESSURE CALIBRATION

• Combine with any Fluke-700G Series Gauge, 1,000 psi range or greater, to make a complete pressure testing kit
• Generates pressure up to 10,000 psi range or greater, to make a complete pressure testing kit
• Connect the 700G Series gauge directly to the HTP-2 hand pump
• Includes 700HTH-1 hose kit and adapters for connecting to the pressure device to be tested
• Hard case protects pump and gauge and allows gauge to remain connected to the pump

 

FLUKE ESA712 ELECTRO-SECURITY ANALYZER FOR MEDICAL EQUIPMENTS

• 5” Touchscreen with intuitive user interface
• Small, portable, ergonomic design with an integratedhandle
• Ten applied parts posts with innovative LED lighting guidance (ECG & Banana)
• Insulation resistance from 50V, 100V, 250V and 500V

 

MULTIFUNCTION PROCESS CALIBRATOR FLUKE 726

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 20 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 4000 O Resistance measure / source / simulate
• 1 to 15 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure

 

CURRENT CLAMP METER TRUE-RMS AC/DC FLUKE 381

• Detachable digital display, read measurements up to 30 feet away
• iFlex fexible current probe included, 18-inch circumference
• 2500 A AC current measurement with iFlex
• 1000 A AC current measurement with fxed jaw
• 1000 V AC and DC voltage measurement
• True-rms AC voltage and current
• Frequency measurement to 500 Hz
• 60-k O resistance measurement
• 500 mV DC measurement range
• 1000 µF capacitance measurement