Multifunctional Tester for Temperature, Humidity, Velocity, CO, CO2 Fluke 075 AirMeter

Code: Fluke 975 AirMeter


 

Datasheet PDF, 0.42 Mb

Description

  • Temperature -20 °C to 50 °C (-5 °F to 122 °F)
  • Velocity 0.25 m/sec to 15 m/sec
  • Relative Humidity 10 % to 90 % RH, non-condensing
  • CO2 0 to 5000 ppm
  • CO 0 to 500 ppm

 

  • Respond to comfort-related calls from occupants.
  • Verify the operation of building HVAC control systems.
  • Determine whether adequate ventilation exists.
  • Monitor air flow and velocity.
  • Test for dangerous carbon monoxide leaks.
  • Perform duct traversals.
  • Optimize HVAC systems to manage energy costs

 

  • Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display
  • One-touch air flow and velocity with available probe*
  • Wet bulb and dew point temperature
  • % of outside air calculation
  • CO2 and CO field calibration feature
  • Self-test function at startup
  • Auto-backlight
  • Automatically compensates for barometric pressure changes
  • Min/Max/Average on all measured and calculated readings
  • Multi-language user interface
  • Metric or standard units
  • Audible and visual threshold alarms
  • Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
  • Keypad lock for security
  • Included FlukeView Forms® software
 

Standard accessories

Fluke 975V      AirMeter™ with Velocity        

Fluke 975         AirMeter™

 

 

  • A4 alkaline batteries (3)
  • Users Manual
  • Calibration Cap
  • FlukeView Forms Software
  • Power Adapter
  • International Power Plugs
  • Air Velocity Probe (Fluke 975V only)
 

More products FLUKE

FLUKE TIX500 INFRARED CAMERA 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 

INTERNAL BATTERY RESISTANCE ANALYZER FLUKE BT520

• Key measurements: Battery resistance, dc and ac voltage, dc and ac current, ripple voltage, frequency and battery temperature.
• Enhanced data analysis: Quickly compare trends, analyze results and create reports with included battery management software.
• Easy reporting: Generate PDF report on the PC software with analysis graphics and data table or quick email format report with csv file on the mobile app.
• Wireless communication
• USB Port

 

FLUKE 1623-2 GEO EARTH GROUND RESISTANCE TESTER

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• Rugged carrying case
• USB data storage and transfer

 

MULTIFUNCTION PROCESS CALIBRATOR FLUKE 725

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 O Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure

 

FLUKE 1587 MEGOHMMETER INSULATION MULTIMETER 50/ 1000V

• Insulation test: 0.01 MO to 2 GO
• Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V

 

FLUKE 700PTPK PNEUMATIC TEST KIT FOR PRESSURE CALIBRATION

• Combine with any Fluke-700G Series Gauge, 1,000 psi (69 bar) or less, to make a complete pressure testing kit
• Generate pressure up to 600 psi, 40 bar with the 700PTP-1 test pump
• Connect the 700G Series gauge directly to the included PTP-1 hand pump
• Includes hoses and adapters for connecting to the pressure device to be tested
• Hard case protects pump and gauge and allows gauge to remain connected to the pump

 

MILIAMP PROCESS CLAMP METER FLUKE 772

• 0 to 24 mA Current measure / source / simulate
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity

 

FLUKE TIX520 INFRARED CAMERA 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 

PRESSURE CALIBRATOR FLUKE 717

• Measure pressure, 0.05% of full scale
• Measure mA with 0.015% accuracy and 0.001 mA resolution
• Measure pressure to 10,000 psi/700 bar

 

FLUKE 8845A DIGITAL BENCH MULTIMETER 6.5 DIGIT

• 6.5 digit resolution
• Basic Vdc accuracy 0.0035 %
• Dual display
• 100 µA to 10 A current range, with up to 100 pA resolution