Fluke 8846A Digital Bench Multimeter 6.5 digit

Code: Fluke 8846A


 

Datasheet PDF, 0.55 Mb

Description

  • 6.5 digit resolution
  • Basic Vdc accuracy 0.0024 %
  • Dual display
  • 100 µA to 10 A current range, with up to 100 pA resolution
  • Wide ohms range from 10 O to 1 GO with up to 10 µO resolution
  • 2 x 4 ohms 4-wire measurement technique
  • Both models measure frequency and period
  • Measures capacitance and temperature
  • USB memory drive port
  • Fluke 45 and Agilent 34401A emulation
  • Graphical display
  • Trendplot™ paperless recorder mode, statistics, histogram
  • CAT I 1000 V, CAT II 600 V
 

Standard accessories

  • TL71 Test Lead Set, Premium DMM
  • LCI Line Cord
  • USB to RS232 Cable Adapter
  • Statement of Calibration Practices
  • WEEE Information Sheet
  • Warranty Information
  • Programmer, Users and Service Manuals (CD-ROM)
  • FlukeView Forms - Basic for 8845/8846
 

More products FLUKE

VIBRATION METER FLUKE 805

• measures overall vibration as well as specific variables like bearing condition and temperature
• calculate bearing condition and overall vibration
• Sensor sensitivity can read a wide range of frequencies (10 to 1,000 Hz and 4,000 to 20,000 Hz)
• Exportable data via USB
• Crest Factor+

 

FLUKE 123B 123B/S INDUSTRIAL SCOPEMETER HAND-HELD OSCILLOSCOPE 2X20MHZ

• 2-channel 20MHz
• Dual-input digital oscilloscope and multimeter
• 40 MHz or 20 MHz oscilloscope bandwidth
• Two 5,000-count true-rms digital multimeters
• Power measurements (W, VA, VAR, PF, DPF, Hz)
• Voltage, current and power harmonics
• Optional WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*

 

FLUKE 43B POWER QUALITY ANALYZER

• Power Quality Analyzer Measures power (W, VA, VAR) and power factor (PF, DPF)
• Oscilloscope Dual-channel scope 20 MHz bandwidth
• Multimeter
• Recorder
• Harmonics Up to 51st
• Power One and three phase

 

FLUKE 113 HANDHELD DIGITAL MULTIMETER 3 1/2 DIGIT

• 3.5 digit
• 6000 count
• 0.5% accuracy
• True-rms for accurate ac measurements on non-linear loads
• VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity

 

FLUKE 1653B MULTIFUNCTION INSTALLATION TESTER 50V-1000V

• Test voltage: 50V, 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results
• Earth resistance

 

ESA710 ELECTRICAL SECURITY ANALYZER FOR TESTING MEDICAL EQUIPMENTS

• 5” Touchscreen with intuitive user interface
• Small, portable, ergonomic design with an integrated handle
• OneQA-enabled workflow automation eliminates need for laptop
• Wireless capability allows you to run test procedures in the field and automatically sync results

 

HVAC CURRENT CLAMP METER 600 A FLUKE 902

• Designed for HVAC applications
• capacitance, DC Current (µA), and temperature measurements
• Small body and jaws

 

WIRELESS CURRENT CLAMP FLUKE CNX A3000

• True-RMS AC current measurements to 400 A
• 2% accuracy to 100 Hz, 2-1/2% accuracy to 500 Hz
• Memory recording up to 65,000 readings
• Backlit LCD display
• CAT III 600 V; IP42


FLUKE 8845A DIGITAL BENCH MULTIMETER 6.5 DIGIT

• 6.5 digit resolution
• Basic Vdc accuracy 0.0035 %
• Dual display
• 100 µA to 10 A current range, with up to 100 pA resolution

 

DOCUMENTING PROCESS CALIBRATOR-HART FLUKE 753

• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement
• HART Capabilities