Voltage detector Fluke 1AC II VoltAlert

Code: Fluke 1AC II VoltAlert


 

Datasheet PDF, 0.26 Mb

Description

  • Voltbeat™ technology and continuous self-test - so you always know it’s working
  • Upon detection, tip glows and beeper sounds
  • CAT IV 1000 V for added protection
  • 200 V to 1000 V AC
  • 20 V to 90 V AC control circuit model also available
  • Two-year warranty
 

Recommended options

  • Fluke 1AC E1 II 5PK VoltAlert, 5 Pack
 

More products FLUKE

INDUSTRIAL MEASUREMENT SYSTEM FLUKE CNX 3000 HVAC

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• Temperature measurements from -200 °C to 1372 °C
• True-RMA AC current measurements to 400 A


FLUKE ESA712 ELECTRO-SECURITY ANALYZER FOR MEDICAL EQUIPMENTS

• 5” Touchscreen with intuitive user interface
• Small, portable, ergonomic design with an integratedhandle
• Ten applied parts posts with innovative LED lighting guidance (ECG & Banana)
• Insulation resistance from 50V, 100V, 250V and 500V

 

FLUKE 190-502 190-502/S HANDHELD DIGITAL OSCILLOSCOPE 2X500 MHZ

• 2-channels isolated 500MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity

 

PROCESS MULTIMETER FLUKE 787

• 0 to 1000 V DC/AC Voltage measure
• 0 to 1 A Current measure
• 0 to 20 mA, 4 to 24 mA Current source
• DMM and loop calibrator in one tool

 

FLUKE 1623-2 GEO EARTH GROUND RESISTANCE TESTER

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• Rugged carrying case
• USB data storage and transfer

 

FLUKE 714B THERMOCOUPLE CALIBRATOR

• measure and simulate (17) different thermocouple types and millivolts
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration

 

INTRINSICALLY SAFE CALIBRATOR FLUKE 725EX

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 O Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure
• ATEX II 1 G Ex ia IIB 171°C KEMA 04ATEX 1303X

 

HVAC CURRENT CLAMP METER 600 A FLUKE 902

• Designed for HVAC applications
• capacitance, DC Current (µA), and temperature measurements
• Small body and jaws

 

CURRENT CLAMP METER AC/DC TRUE-RMS 2000 A FLUKE 355

• 2000 A AC + DC true-rms, 1400 A AC, and 2000 A DC
• large 58 mm (2.3 in) jaw capacity
• 1000 V AC + DC true-rms, 600 V AC, and 1000 V DC
• Accurately measure frequency up to 1 kHz
• Resistance to 400 Kohms

 

FLUKE 6304/ 6304C AUTOMATIC RCL METER 50 HZ..100 KHZ

• 50, 60, 100, 120 Hz, 200 Hz to 20 kHz (100 Hz steps), 100 kHz test frequencies
• 0.1 % basic accuracy (0.05 % for PM 6304C)
• Easy to use, at-a-glance display