Voltage Continuity Tester Fluke T50

Code: Fluke T50


 

Datasheet PDF, 0.09 Mb

Description

  • Voltage test
  • Optical and acoustical continuity test
  • Display: 10 LED's
  • Single pole test for phase detection
  • Indication of polarity
  • The voltage display also functions when using discharged - or no batteries
 

Standard accessories

  • 2 batteries 1.5 V and instruction sheet
  • instruction manual
 

More products FLUKE

INDUSTRIAL VOLTAGE AND CURRENT MEASUREMENT SYSTEM FLUKE CNX 3000 IND

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC current measurements to 2500 A
• True-RMS AC voltage measurements to 1000V
• CAT III 1000 V, CAT IV 600 V, CAT III 1000 V; IP42


FLUKE 175 HANDHELD DIGITAL MULTIMETER 3.5 DIGIT

• 3.5 digit
• 6000 count resolution
• 0.15% basic accuracy
• True RMS voltage and current measurements

 

WIRELESS AC CURRENT MEASUREMENT KIT FLK-CNX I3000 IFLEX KIT

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC current measurements to 2500 A
• Memory recording up to 65,000 readings
• CAT III 1000, CAT IV 600 V; IP42


INTERNAL BATTERY RESISTANCE ANALYZER FLUKE BT510

• Key measurements: Battery resistance, dc and ac voltage, dc and ac current, ripple voltage, frequency and battery temperature.
• Enhanced data analysis: Quickly compare trends, analyze results and create reports with included battery management software.
• Easy reporting: Generate PDF report on the PC software with analysis graphics and data table or quick email format report with csv file on the mobile app.
• Wireless communication
• USB Port

 

VIBRATION METER FLUKE 805

• measures overall vibration as well as specific variables like bearing condition and temperature
• calculate bearing condition and overall vibration
• Sensor sensitivity can read a wide range of frequencies (10 to 1,000 Hz and 4,000 to 20,000 Hz)
• Exportable data via USB
• Crest Factor+

 

DIGITAL CONTACT THERMOMETERS SERIES FLUKE 50 II

• Relative time clock on MIN, MAX, and AVG provides a time reference for major events
• Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
• Measures J, K, T, and E-types of thermocouples
• Readout in ºC, ºF, or Kelvin (K)
• Data Logging up to 500 points of data with user adjustable recording interval(Fluke 53 II and Fluke 54 II)

 

FLUKE TIS45 INFRARED CAMERA 160X120

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 753

• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement

 

WIRELESS CURRENT CLAMP FLUKE CNX A3000

• True-RMS AC current measurements to 400 A
• 2% accuracy to 100 Hz, 2-1/2% accuracy to 500 Hz
• Memory recording up to 65,000 readings
• Backlit LCD display
• CAT III 600 V; IP42


FLUKE MEMOBOX 1745 THREE PHASE POWER QUALITY LOGGER

• monitor & logging: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
• measures voltage & current harmonics, interharmonics, mains signaling, unbalance, frequency
• Plug and play
• Determines the root cause
• Monitors power for the long-term
• 0.1% voltage accuracy IEC61000-4-30 Class-A compliant
• five hour UPS
• IP50 advanced protection