Intrinsically Safe Pressure Calibrator Fluke 718

Code: Fluke 718


 

Datasheet PDF, 0.54 Mb

Description

  • ATEX II  1G Ex ia IIC T4 Compliant
  • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules
  • Wide range of selectable measurement units for pressure
  • Current measurement with 0.02% accuracy and 0.001 mA resolution
  • Pressure switch test function
  • Min-Max Hold functions
  • Compact size and weight
  • Simple, push-button user interface
  • Rugged and reliable, ideal for field use
 

Standard accessories

  • Protective Red Holster
  • TL75 Test Leads
  • AC72 Test Clips
  • CD Users Manuals
  • Fluke 718Ex CCD content control drawing
  • NIST- traceable calibration report and data
 

Recommended options

Fluke 718EX 30

Pressure Calibrator 30 PSI, EX - I.S.

Fluke 718EX 100G

Pressure Calibrator 100 PSI, EX - I.S

Fluke 718EX 300G

Pressure Calibrator 300 PSI, EX - I.S

 

More products FLUKE

ELECTRIC PRESSURE CALIBRATOR FLUKE 719

• Best in class pressure measurement uncertainty of 0.025%
• Measure and source mA with best in class 0.015% accuracy
• 30 PSI and 100 PSI pressure ranges

 

CURRENT CLAMP METER TRUE-RMS AC/DC FLUKE 381

• Detachable digital display, read measurements up to 30 feet away
• iFlex fexible current probe included, 18-inch circumference
• 2500 A AC current measurement with iFlex
• 1000 A AC current measurement with fxed jaw
• 1000 V AC and DC voltage measurement
• True-rms AC voltage and current
• Frequency measurement to 500 Hz
• 60-k O resistance measurement
• 500 mV DC measurement range
• 1000 µF capacitance measurement

 

WIRELESS TEMPERATURE K-TYPE ACQUISITION MODULE FLUKE CNX T3000

• Temperature measurements from -200 °C to 1372 °C
• ± 0.5% accuracy
• Memory recording up to 65,000 readings
• Backlit LCD display
• IP30


HANDHELD LOOP CALIBRATOR FLUKE 705

• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.02%

 

FLUKE 721 PRESSURE CALIBRATOR

• 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor
• 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
• Ideal for gas flow calibration (custody transfer) applications
• Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
• Pt100 RTD input for temperature measurement, (probe optional)
• Measures 4 to 20 mA signals
• Internal 24 V loop power supply can power a transmitter under test
• Measure up to 30 V dc, check 24 V loop power supplies

 

VOLTAGE CONTINUITY TESTER FLUKE T90/ T110/ T130/ T150

• Voltage AC/DC 12V - 690V
• Continuity 0 - 400 k?
• Frequency 0 / 40 - 400 Hz
• Phase rotation
• Resistance measurement

 

FLUKE II905 ACOUSTIC CAMERA IMAGER FOR INSPECTINA AND DETECTION COMPESSED AIR

• Easy, fast, and safe visual detection of compressed gas leaks with LeakQ mode including estimated leak size and cost.
• The 7" LCD touchscreen overlays a SoundMap on visual images, facilitating rapid leak location identification.
• The integrated visual- and textual tagging and annotation functionalities offer important details to optimize reporting and follow-up actions.

 

HANDHELD TEMPERATURE CALIBRATOR FLUKE 724

• -10 to 75 mV, 0 to 10 V Voltage source
• -10 to 75 mV, 0 to 30 V Voltage measure
• 0 to 24 mA Current measure
• 0 to 3200 O Resistance measure / source

 

FLUKE 287 HANDHELD DIGITAL DATA LOGGING MULTIMETER 4.5 DIGIT

• 4.5 digit large ¼ VGA display with white backlight
• 50,000 count
• 0.025% basic accuracy
• Logging function with TrendCapture

 

FLUKE 8845A DIGITAL BENCH MULTIMETER 6.5 DIGIT

• 6.5 digit resolution
• Basic Vdc accuracy 0.0035 %
• Dual display
• 100 µA to 10 A current range, with up to 100 pA resolution