Intrinsically Safe Pressure Calibrator Fluke 718

Code: Fluke 718


 

Datasheet PDF, 0.54 Mb

Description

  • ATEX II  1G Ex ia IIC T4 Compliant
  • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules
  • Wide range of selectable measurement units for pressure
  • Current measurement with 0.02% accuracy and 0.001 mA resolution
  • Pressure switch test function
  • Min-Max Hold functions
  • Compact size and weight
  • Simple, push-button user interface
  • Rugged and reliable, ideal for field use
 

Standard accessories

  • Protective Red Holster
  • TL75 Test Leads
  • AC72 Test Clips
  • CD Users Manuals
  • Fluke 718Ex CCD content control drawing
  • NIST- traceable calibration report and data
 

Recommended options

Fluke 718EX 30

Pressure Calibrator 30 PSI, EX - I.S.

Fluke 718EX 100G

Pressure Calibrator 100 PSI, EX - I.S

Fluke 718EX 300G

Pressure Calibrator 300 PSI, EX - I.S

 

More products FLUKE

FLUKE TIS20 INFRARED CAMERA 120X90

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

TRUE-RMS CURRENT CLAMP METER 400 A FLUKE 325

• 400 A ac and dc current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Resistance measurement up to 40 k? with continuity detection
• Temperature and capacitance measurement
• Frequency measurement

 

PRESSURE CALIBRATOR FLUKE 718

• Pressure Source and Milliamp Measurement
• Best in class mA accuracy of 0.015 %
• 1, 30, 100 & 300 PSI ranges available

 

FLUKE 700PTP-1 PNEUMATIC TEST PUMP FOR PRESSURE CALIBRATION

• Ideal for calibrating pressure transmitters, pressure switches and pressure gauges up to 600 PSI/40 bar
• Pump can be easily cleaned without disassembly
• The vernier can be used as a stand-alone low pressure calibration source
• Two pressure ports allowing simultaneous connection:
• ¼ -NPT female fitting for the reference gauge or pressure module
• ¼" NPT female fitting for the unit under test
• Adjustable stroke length can be set to limit the pressure per stroke

 

TRUE-RMS CURRENT CLAMP METER 400 A FLUKE 323

• 400 A ac current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Resistance measurement up to 40 k? with continuity detection

 

CARBON MONOXIDE TESTER FLUKE CO-220

• Rugged case and electronics.
• Large LCD displays CO levels from 0 to 1000 ppm.
• Bright back-light allows easy screen viewing under dim lighting conditions.
• Beeper triggers with increasing frequency as CO levels rise.
• MAX Hold function stores and displays the maximum CO level.
• Automatic sensor zeroing and self-test sequence upon start-up.

 

FLUKE 1654B MULTIFUNCTION INSTALLATION TESTER 50V-1000V

• Test voltage: 50V, 100V, 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results
• Earth resistance

 

INDUSTRIAL VOLTAGE AND CURRENT MEASUREMENT SYSTEM FLUKE CNX 3000 IND

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC current measurements to 2500 A
• True-RMS AC voltage measurements to 1000V
• CAT III 1000 V, CAT IV 600 V, CAT III 1000 V; IP42


FLUKE 83V HANDHELD DIGITAL MULTIMETER 3.75 DIGIT

• 3.75 digit
• 6000 count resolution
• 0.1% basic accuracy

 

AIR QUALITY PARTICLE COUNTER FLUKE 985

• Six channels and particle size range of 0.3 - 10.0 µm
• Ultra-lightweight and ergonomic design
• Large 3.5 QVGC Color display
• 10,000 record storage
• USB/Ethernet charge cradle