The Fluke 570 non-contact thermometers are ideal professional diagnostic tools for maintenance professionals requiring the most accurate temperature readings at all distances. The Fluke 570 series infrared (IR) measures surface temperatures, helping to quickly locate lubrication problems, overloads, short-circuits or misaligned and overheated equipment, reducing work and follow-up time, and improving performance.

From close-up electrical connections, to distant room balancing checks, the Fluke 570 series can take IR temperature measurements with ease. Predictive maintenance professionals requiring analysis and documentation use the 574 model with 100-point data logging and included software for graphing and analysis for follow-up reporting and documentation.

 

  • Backlit display for poorly lit areas
  • Last ten temperature readings displayed on bar graph for easy reference
  • Enhanced optics (distance to spot ratio up to 60:1) allow measurements of smaller objects from farther away
  • Coaxial three-dot laser sighting system highlights the true diameter of measurement spots at all distances (90% energy)
  • Extra bright appearing 635nm laser (tested to the same safety and power standards as less bright laser sights) to clearly highlight the targeted area
  • Close-focus option available for specialized applications
  • MIN/MAX measurements calculations instantly computed
  • Audible and visible HI temperature alarm for instant recognition
  • Comfortable, overmolded pistol grip makes target sighting easy
  • Adjustable emissivity setting (.01 increments) for more accurate measurement
  • Durable hard plastic storage case included
  • DIF/AVG measurement calculations instantly computed
  • 100 temperature data logging capability for easy route review
  • 30 pre-set common material emissivity values for most accurate temperature readings
  • Audible and visible HI and LO temperature alarm for instant recognition
  • Thermocouple K probe input for contact temperature measurements with same unit
  • Customizable log names, alarms, and emissivity values for more efficient, less error-prone predictive maintenance routes
  • Windows-based (Windows NT/ 2000/XP) software for data storage and analysis
  • Software to log, graph, and analyze temperature data via RS232 connection
 
 

Standard accessories

Fluke 574 Precision Infrared Thermometer 
Includes:

  • Durable hard case
  • Thermocouple K probe
  • Power supply
  • RS232 data cable
  • Data graphing, storage, and analysis software
  • 2 AA batteries

 

 

 

Fluke 574CF Precision Infrared Thermometer Close Focus 
Includes:

  • Standard Fluke 574 accessories
  • Close Focus Option available for specialized applications, such as electrical components, features minimum measurement diameter 6mm (0.24") and Distance to Spot (D:S): 50:1
 

Recommended options

Temperature

80PK-11

80PK-11 Type-K Flexible Cuff Thermocouple Temperature Probe

80PK-27

80PK-27 Industrial Surface Probe

80PK-8

80PK-8 Pipe Clamp Temperature Probe (Type K)

 

More products FLUKE

MULTIFUNCTION PROCESS CALIBRATOR FLUKE 726

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 20 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 4000 O Resistance measure / source / simulate
• 1 to 15 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure

 

FLUKE TOPAS 1760 THREE PHASE POWER QUALITY RECORDER

• 8 input channels
• Fully IEC 61000-4-30 Class-A standard compliant
• Power quality statistics according to EN50160, DISDIP tables, ITIC, CEBEMA, ANSI
• 10 MHz, 6000 Vpk waveform capture
• GPS time synchronization
• records rms, min, max values for: Voltage Current Power P, Q, S Power Factor kWh Flicker Unbalance Frequency Harmonics Interharmonics

 

FLUKE TIS45 INFRARED CAMERA 160X120

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

FLUKE 8846A DIGITAL BENCH MULTIMETER 6.5 DIGIT

• 6.5 digit resolution
• Basic Vdc accuracy 0.0024 %
• Dual display
• 100 µA to 10 A current range, with up to 100 pA resolution

 

VOLTAGE DETECTOR FLUKE LVD2 VOLT LIGHT

• Detects voltages from 40 V AC to 300 V AC
• Non-contact AC voltage detector and LED flashlight
• exclusive dual-sensitivity

 

FLUKE VT04 INFRARED THERMOMETER WITH INTEGRATED CAMERA

• take simultaneous visual images with the thermal heat map images that are accurately aligned close in
• Temperature measurement range -10 °C to +250 °C (14 °F to 482 °F)
• Infrared spectral band 6.5 µm to 14 µm
• Minimum focus distance 50 cm (19.6 in)
• Field of View 28° X 28°
• 4 GB Micro SD card

 

CURRENT CLAMP METER TRUE-RMS AC/DC FLUKE 381

• Detachable digital display, read measurements up to 30 feet away
• iFlex fexible current probe included, 18-inch circumference
• 2500 A AC current measurement with iFlex
• 1000 A AC current measurement with fxed jaw
• 1000 V AC and DC voltage measurement
• True-rms AC voltage and current
• Frequency measurement to 500 Hz
• 60-k O resistance measurement
• 500 mV DC measurement range
• 1000 µF capacitance measurement

 

FLUKE II915 ACUSTIC CAMERA FOR GAS LEAKS, ELECTRICAL DISCHARGES, AND MECHANICAL FAULTS

• Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
• LeakQ™ Mode: Estimated leak size and cost.
• PDQ Mode™: Assesses discharge severity.
• MecQ™ Mode: Proactively address potential problems in rotating mechanical components.
• Reporting Features: Integrated visual and textual tagging and annotation functionalities for streamlined reporting.
• Wireless Upload: Easily transfer data to Fluke Connect.

 

HANDHELD TEMPERATURE CALIBRATOR FLUKE 724

• -10 to 75 mV, 0 to 10 V Voltage source
• -10 to 75 mV, 0 to 30 V Voltage measure
• 0 to 24 mA Current measure
• 0 to 3200 O Resistance measure / source

 

FLUKE 6306 AUTOMATIC RCL METER 50 HZ..1 MHZ

• 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps)
• 100 kHz to 1 MHz (1 kHz steps) test frequencies
• 0.1 % basic accuracy
• Easy to use, at-a-glance display