Description

  • Automated Measurement with Optional Software
  • Field Uniformity Better than 3 dB Over Operating Range
  • Compact Bench-Top Design
  • Frequency Range of 1.0 GHz to 40 GHz
  • Radiated Immunity and Emissions Measurements
    IEC61000-4-21
    MIL-STD-461E
  • Fast Measurement Time
  • Two Year Warranty

 

Electrical Specifications

Frequency Minimum

1.0 GHz

Frequency Maximum

40 GHz

 

Standard accessories

  • Chamber calibration from 1.0 GHz to 40 GHz per IEC 61000-4-21
  • Two Year Warranty
  • One Type N and one Type K connector for horns
  • Two double ridged horn antennas (mounted)
  • One vertical, one horizontal tuner, with stepper motors
  • SMART 1000 Mini-Reverb Assembly
 

Recommended options

  • SMARTImm Immunity software
  • Additional N, SMA, 2.9, 3.5, or Type K connectors
  • SMARTEMI Emissions software
 

More products ETS-LINDGREN

PORTABLE TEST ENCLOSURE FOR EMI/RFI TEST ETS-LINDGREN 5240

• Ease of operation in a compact, portable format
• Maximum performance Double Electrically Isolated (DEI) RF door with toggle action over center draw latches
• High performance 24 ounce copper shielding construction
• Shielding performance of 120 dB+

 

BROADBAND BICON ANTENNA WITH RADOME PROTECTION 1..18 GHZ ETS-LINDGREN 3184

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• VSWR Ratio (AVG) 2:1
• Maximum Continuous Power 50 watts @ 1 GHz, 25 watts @ 18 GHz
• Broadband Spectrum Monitoring
• Harmonics Level Measurement IEC 61000-4-3

 

DUAL POLARIZED LOG PERIODIC ARRAY ANTENNA 100 MHZ..1.1 GHZ ETS-LINDGREN 3145BDP

• Frequency Range 100 MHz - 1.1 GHz
• Input Impedance 50 ?
• VSWR 1.5:1 average, 3.5:1 maximum
• Maximum RF input power 800 W
• Stainless Steel Construction
• Dual Linearly Polarized

 

ELECTROMAGNETIC FIELD EMISSION MEASURING TESTER OF VIDEO DISPLAYS ETS-LINDGREN HI-3603

• VDT / VLF Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings

 

HIGH CURRENT POWER PROTECTION FILTERS IN THREE PHASE NETWORK AND RFI/EMP SYSTEMS 400..800A ETS-LINDGREN N258X

• Current Rating 800 Amps
• Frequency 50/60 Hz
• Number of Lines 4
• Voltage Frequency Maximum 440/250
• Tempest Capability
• Ideal for EMPP systems

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 400 MHZ..10 GHZ ETS-LINDGREN 3164-10

• Frequency Minimum 400 MHz
• Frequency Maximum 10 GHz
• VSWR Ratio (AVG) 5:1 maximum, 1.75:1 average
• Maximum Continuous Power 100 watts @ 400 MHz, 20 watts @ 10 GHz
• Impedance (Nominal) 50 ?

 

CONICAL LOG SPIRAL ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3103

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 100 W
• Pattern Type directional
• Peak Power 100 W
• Polarization circular
• VSWR 1.6:1
• Two Year Warranty
• Extremely low VSWR

 

ELECTRIC & MAGNETIC FIELD RF INDUSTRIAL COMPLIANCE TESTER 10..42 MHZ ETS-LINDGREN HI-3408

• 13.56 MHz, 27.12 MHz, 40.68 MHz Cal Frequencies
• Field Intensity Bar Graph
• On-Board Data Logging and Review
• Low Cost EMF Detection
• Electric and Magnetic Field Strength Measurements
• Data Logging (Up to 112 Points)

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMP APPLICATIONS CURRENTS 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

MAGNETIC SHIELDED COIL ANTENNA LOW FREQUENCIES 30 HZ..100 KHZ ETS-LINDGREN 7605/ 7606

• Frequency Minimum 30 Hz
• Frequency Maximum 100 kHz
• Connectors Banana Jack (2) - [7605], BNC - [7606]
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear