High Performance Control Filters for Tempest/ EMP/ EMI applications currents 2..10A ETS-Lindgren N502X/ N503X

Code: ETS-Lindgren N502X/ N503X


 

Datasheet PDF, 0.35 Mb

Description

  • Current Rating  2 Amps
  • Number of Lines           2
  • Voltage Frequency Maximum   100/DC
  • Current range up to 10 Amperes
  • Inter-changeable with L2962/72
  • Protection for Tempest and EMP
  • Low volt drop
  • AC and DC Options
 

More products ETS-LINDGREN

DOUBLE-RIDGET HORN ANTENNA FOR EMC MEASUREMENTS 18..40 GHZ ETS-LINDGREN 3116B

• Frequency Minimum 18 GHz
• Frequency Maximum 40 GHz
• VSWR Ratio (AVG) 2.5:1 max
• Maximum Continuous Power 20 W
• Peak Power 200 W
• Impedance (Nominal) 50 ?

 

PORTABLE TEST ENCLOSURE FOR EMI/RFI TEST ETS-LINDGREN 5240

• Ease of operation in a compact, portable format
• Maximum performance Double Electrically Isolated (DEI) RF door with toggle action over center draw latches
• High performance 24 ounce copper shielding construction
• Shielding performance of 120 dB+

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3164-01

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• VSWR Ratio (AVG) 3:1 maximum
• 1.75:1 average
• Maximum Continuous Power 750 watts @ 100 MHz
• 200 watts @ 1 GHz
• Impedance (Nominal) 50 ?
• Connectors (2) Type N Female

 

PROTECTION TEMPEST/ RFI/ EMI FILTERS FOR TELECOM ETS-LINDGREN N24X/ N29X

• Suitable for EMI, EMP and Tempest protection
• Tubular, flat-pack or modular design
• 100dB insertion loss
• New ISDN filters now available
• Matched to balanced 600 Ohm lines

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ RFI/ EMI TEST CURRENTS 6..100A ETS-LINDGREN N255X

• Maximum protection in Tempest and EMPP applications
• Highest performing commercially available power line filter
• Over 100dB insertion loss from 10 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive

 

BULK INJECTION CURRENT PROBES 10 KHZ..400 MHZ ETS-LINDGREN 95236-1/ 95242-1

• 95236-1: frequency range is 10 kHz to 100 MHz
• 95242-1: frequency range is 2 MHz to 400 MHz
• Maximum Power: 100W

 

MAGNETIC FIELD MEASUREMENT PROBE 300 KHZ..300 MHZ ETS-LINDGREN HI-4433

• Frequency Range: 300 kHz - 300 MHz
• Magnetic Field Sensing: 5-300 MHz
• Automatic Continuous Zeroing
• Data from each axis can be viewed individually
• Isotropic Detection

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 700 MHZ..10 GHZ ETS-LINDGREN 3164-08

• Frequency Minimum 700 MHz
• Frequency Maximum 10 GHz
• Cross Polarization Isolation >20 dB
• Impedance 50 ?
• Connector Input Power SMA Female (2)
• 700 MHz - 10 GHz Frequency Range
• Linear or Circular Polarization (With Hybrid)

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4