Hybrid Log Periodic Broadband Antenna for EMC measurements 26 MHz..3 GHz ETS-Lindgren 3140B

Code: ETS-Lindgren 3140B


 

Datasheet PDF, 0.77 Mb

Description

  • Frequency Minimum     26 MHz
  • Frequency Maximum    3 GHz
  • Connectors       Type N
  • Impedance (Nominal)   50 ?
  • Maximum Continuous Power    1 kW
  • Pattern Type     directional
  • Peak Power     1.3 kW
  • Polarization       linear
  • VSWR 2.0:1
  • 26 MHz - 3 GHz Frequency Range
  • Two Year Warranty
  • Fits Compact Chambers
  • Tough powder coat finish
  • Avg. 2:1 VSWR Above 80 MHz
  • Best EMC RI Performance from 26 MHz - 80 MHz<=300 W to generate 10 V/m
  • Above 30 MHz at 3m, 80% AM
 

More products ETS-LINDGREN

HIGH GAIN CONICAL HORN ANTENNA WITH LINEAR POLARIZATION 4..26.5 GHZ ETS-LINDGREN 3163

• Conical Shape
• Series Frequency Range: 4 GHz to 26.5 GHz
• High Gain
• Low VSWR

 

ACTIVE RECEIVING LOOP ANTENNA 10 KHZ..30 MHZ ETS-LINDGREN 6502

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• 1 dB Comp. Point 5 V/m
• Connectors BNC (f)
• Dynamic Range 125 dB @ 1 MHz, 85dB @ 10 kHz
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3164-01

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• VSWR Ratio (AVG) 3:1 maximum
• 1.75:1 average
• Maximum Continuous Power 750 watts @ 100 MHz
• 200 watts @ 1 GHz
• Impedance (Nominal) 50 ?
• Connectors (2) Type N Female

 

ACTIVE MONOPOLE RECEPTION ANTENNA 30 HZ..50 MHZ ETS-LINDGREN 3301C

• Frequency Minimum 30 Hz
• Frequency Maximum 50 MHz
• Connectors BNC (f)
• Impedance (Nominal) 50 ?
• Polarization linear
• 30 hours of continuous operation in a single charge

 

ELECTROMAGNETIC LEAKAGE AUTOMATIC SCANNING METER OF MICROWAVE OVEN ETS-LINDGREN HI-1710A

• Digital Alarm Set
• Auto-ranging
• RS-232 Interface
• Removable Sensing Probe
• Optional Remote Zero
• Analog bar graph
• Serial Printer Output

 

E-FIELD GENERATOR LINEAR POLARIZED 10 KHZ..30 MHZ ETS-LINDGREN 3107B

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1000 W
• Peak Power 1500 W
• Polarization linear
• Linear Polarization

 

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION CURRENTS 6..100A ETS-LINDGREN N182X

• Current Rating 6 Amps
• Number of Lines 2
• 100dB insertion loss
• High protection rate against EMI

 

INDUCED RF CURRENT METER 9 KHZ..70 MHZ ETS-LINDGREN HI-3702

• Wide Frequency Response (9 kHz - 70 MHz)
• Eliminates concern over foot contact and body orientation
• Monitors induced current while standing, walking, or climbing.
• Thermally based True RMS Converter Circuit for increased accuracy

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5411

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

BICONICAL LINEAR POLARIZED ANTENNA 30..100 MHZ ETS-LINDGREN 3159

• Frequency Minimum 30 MHz
• Frequency Maximum 100 MHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 15 kW
• Pattern Type omnidirectional
• Polarization linear