Multifunction Electrical Machine Tester Chauvin Arnoux CA6155

Code: Chauvin Arnoux CA6155


 

Datasheet PDF, 1.21 Mb

Description

The multi-function C.A 6155 can be used for all the measurements required to test the electrical safety of portable electrical equipment, machines and switchgear.

 

It provides a wide range of fully-compliant measurements:

- Measurements in compliance with the IEC 60204

Ed.5 / VDE701/702 / IEC 61439 (IEC 60439) standards

- 200 mA and 10 A continuity measurements

- Insulation resistance at 250 VDC and 500 VDC

- Dielectric test at 1,000 V / 1,890 V / 2,500 V

- Leakage current measurement by substitution method

- Differential leakage current

- Contact leakage current

- Mains power-lead polarity test

- Functional test with consumption measurement

- TRMS leakage and load current measurements (current clamp available as option)

- RCD test (including portable RCDs)

- Loop impedance and line impedance measurement with calculation of short-circuit currents

- Discharge time

- Phase rotation

- Voltage / frequency measurements

- Functional and visual inspections.

 

Standard accessories

C.A 6155. . .. . . . . . . . P01146001

Delivered with an accessories bag containing:

- 1 high-voltage test probe

- 1 mains-socket test cable

- 1 test cable with separate wires

- 1 red lead 1.5 m long

- 1 black lead 1.5 m long

- 1 green lead 1.5 m long

- 1 red lead 4 m long

- 4 test probes

- 3 crocodile clamps

- 1 operating manual in 5 languages

- 1 USB communication cable

- 1 RS232 communication cable

- Data transfer software

 

Recommended options

 

 

More products CHAUVIN ARNOUX

EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6472

• 5 tools in 1 with this tester
• extensive measurement ranges: 0.001?to 100 k?
• analysing the frequency behaviour of the earthing systems (from 41 Hz to 5 kHz)
• high-level, expert calculation capabilities
• IP 53 leakproofing

 

EARTH GROUND RESISTANCE TESTER CHAUVIN ARNOUX CA6460

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

INSULATION MEGOHMMETER 5000V CHAUVIN ARNOUX CA6545

• wide range from 30k? to 10T? !
• 4 fixed test voltages: 500/1,000/2,500 and 5,000V
• programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V
• giant backlit LCD screen with digital display + bargraph
• qualitative analysis: automatic calculation of DAR, PI and DD

 

ENERGY POWER ANALYZER CHAUVIN-ARNOUX CA8230

• Voltage range: 6VRMS to 600VRMS AC+DC
• AC current range: 5mA to 6,500A
• DC current range: 1A to 1,700A
• Values: Min., Max., Avg., Peak (+/-), CF
• Power: W, VA, var, DF, THD, cos f, tan f
• Energy: Wh, VAh, varh
• Harmonics: up to the 50th order
• IEC1010/EN61010: Cat.III-600V

 

ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6114

• automatic installation status test immediately after connection
• measurement of voltage (10 to 440V AC/DC) and frequency (15.3 to 450Hz)
• installation insulation measurement at 500V
• standard earth connection resistance measurement (1 stake + loop method)
• PE conductor continuity test
• measurement of internal loops
• testing of RCDs up to 500mA (exact tripping time and current)
• phase rotation testing

 

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6471

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods
• Ergonomic, comprehensive and accurate

 

SOLAR PANEL EFFICIENCY TESTER CHAUVIN ARNOUX FTV100 GREENTEST

• electrical power survey
• Calculation of solar panel efficiency
• Calculation of inverter efficiency
• Voltage up to 1,000 VDC / 600 VAC
• Current up to 1,400 ADC / 3,000 AAC
• AC/DC power: 20,000 WDC / 1,200 WAC

 

MEGOHMMETER 15KV CHAUVIN ARNOUX CA6555

• Wide measurement range from 10 kohm to 30 Tohm
• Fixed or programmable test voltage from 40V to 15 kV
• 5mA max. charging current
• Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs
• Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)
• Multiple test modes: voltage ramp and step with "burning", "early break" and "I-limit" modes

 

EARTH GROUNDING RESISTANCE TESTER CHAUVIN ARNOUX CA6462

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

MEGOHMMETER 10KV CHAUVIN ARNOUX CA6550

• Wide measurement range from 10 kohm to 25 Tohm
• Fixed or programmable test voltage from 40V to 10 kV
• 5mA max charging current
• Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs
• Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)