Digital Insulation Megohmmeter 500V Chauvin Arnoux CA6533

Code: Chauvin Arnoux CA6533


 

Description

Ideal for tests on telephone lines or electronic equipment, the C.A 6533 megohmmeter measures insulation at 50V, 100V, 250V and 500V, as well as resistance. It indicates the AC/DC voltage before each measurement.

 

  • insulation: up to 20G? at 50V, 100V, 250V and 500V
  • voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
  • resistance: 0 to 400kO
  • giant 4,000-count display + bargraph (simultaneous reading of the measurement and analogue variation)
  • backlit display
  • programmable alarms
  • DREL function for testing for the presence of transmission frame or measurement of the difference in resistance between 2 wires of a pair
  • remote control probe (option)
  • back stand for use on a table or on the ground
  • long battery life: 6 x 1.5V batteries
  • Measurements in compliance with IEC 61557, NF C 15-100, VDE 0413
  • electrical safety: IEC 1010 300V Cat. III

 

 

 

Standard accessories

C.A 6531...................P01140804B

C.A 6533...................P01140805

 

½ 1 "hands-free" carrying case

½ 1 pair of 1.5 m leads, red + black

(the leads on C.A 6533 are guarded)

½ 1 red croc-clip

½ 1 black test probe

½ 2 wire grips, red + black

½ 6 LR6 batteries

½ 1 set of operating instructions.

* + 1 blue 1.5 m lead and 1 blue croc-clip for model C.A 6533

 

More products CHAUVIN ARNOUX

EARTH GROUND RESISTANCE TESTER CHAUVIN ARNOUX CA6460

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

SOLAR PANEL EFFICIENCY TESTER CHAUVIN ARNOUX FTV100 GREENTEST

• electrical power survey
• Calculation of solar panel efficiency
• Calculation of inverter efficiency
• Voltage up to 1,000 VDC / 600 VAC
• Current up to 1,400 ADC / 3,000 AAC
• AC/DC power: 20,000 WDC / 1,200 WAC

 

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6471

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods
• Ergonomic, comprehensive and accurate

 

THREE-PHASE POWER QUALITY ANALYZER CHAUVIN-ARNOUX CA8435

• C.A 8435, the rugged, waterproof IP67
• Indoor and outdoor use, even when it is raining
• 5 voltage inputs, 4 current inputs
• Continuous recording of all the parameters simultaneously
• Monitoring with alarms
• All types of installations
• Measurement of P, Q, S and D power values (total and per phase)
• Calculation of Pst & Plt flicker values

 

EARTH GROUNDING RESISTANCE TESTER CHAUVIN ARNOUX CA6462

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

THREE-PHASE ENERGY QUALITY ANALYZER CHAUVIN-ARNOUX CA8334B QUALISTAR

• Complete three-phase analysis:
• - voltage, current,
• - power / energy,
• - harmonics (up to 50th order), flicker,
• - measurement of transients,
• - alarm trigger...
• Processing of data via PC software QualistarView or DataViewer Pro.
• Recording of 12 screens
• Compliant with IEC 61010-1, 600V Cat.IV

 

INSULATION MEGOHMMETER 5000V CHAUVIN ARNOUX CA6545

• wide range from 30k? to 10T? !
• 4 fixed test voltages: 500/1,000/2,500 and 5,000V
• programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V
• giant backlit LCD screen with digital display + bargraph
• qualitative analysis: automatic calculation of DAR, PI and DD

 

DIGITAL INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6533

• insulation: up to 20G? at 50V, 100V, 250V and 500V
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• resistance: 0 to 400kO
• giant 4,000-count display + bargraph
• backlit display
• programmable alarms


MULTIFUNCTION ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6116

• ALL-IN-ONE tool for electrical installation testing
• compliance with the national and international standards (IEC 60364-6, NF C 15-100, VDE 100, XP C 16-600...
• design, ergonomics, simplicity, rapidity and accuracy
• Suitable for all types of neutral systems (TT, TN, IT)
• large backlit graphic screen

 

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6470N TERCA3

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods