Insulation Resistance Megohmmeter 1kV Chauvin Arnoux CA6541

Code: Chauvin Arnoux CA6541


 

Datasheet PDF, 0.52 Mb

Description

The C.A 6541 is a high-performance 50V to 1kV insulation tester; it supports the most demanding site conditions and is ideal for qualitative insulation analysis.

 

  • insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
  • automatic calculation of insulation quality ratios: DAR and PI
  • programmable test period and plotting of the R(t) curve (automatic memorisation of 20 samples)
  • automatic indication of voltage before and after measurement: 1 to 1000V AC/DC
  • resistance: from 0.01O to 400kO
  • continuity: 0.01O to +40O (audible beep and lead compensation)
  • automatic measurement capacity after each insulation measurement: 0.005 to 4.999 ½F
  • microprocessor-controlled
  • giant LCD screen with digital display + bargraph
  • backlit display
  • SMOOTH function (smoothing of values displayed)
  • insulation test voltages can be locked
  • programmable alarms

½          long battery life: 8 x LR14 batteries (21,000 insulation tests of 5s each)

½          remote control probe available as an option

½          electrical security: IEC 61010-1 + A2 ½ Cat. III - 600V and IEC 61557

½          dimensions: 240 x 185 x 110mm; weight: 3.4kg

 

 

 

Standard accessories

C.A 6541 P01.1389.01

C.A 6543 P01.1389.02

 

Complete with carrying bag containing all the accessories:

_ 2 x 1.5 m safety leads (red/blue)

_ 1 x 1.5 m guarded safety lead (black)

_ 3 x crocodile clips (red/blue/black)

_ 1 x test probe (black)

_ 1 x 2-sided condensed user½s manual

_ 1 user½s manual

_ 8 x LR14 batteries (for C.A 6541)

or 1 x 2m mains lead (for C.A 6543)

 

Recommended options

OPTIONAL ACCESSORIES:

Remote control probe P01.1019.35

PC software for C.A 6543 P01.1019.38

Serial printer for C.A 6543 P01.1029.03

Serial-to-parallel adapter

for C.A 6543 P01.1019.41

Pair of 2 test probe leads

(red/ black) P01.1018.55

Set of 3 x 3m safety leads

(red/blue/guarded black) P01.2951.70

 

More products CHAUVIN ARNOUX

ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6114

• automatic installation status test immediately after connection
• measurement of voltage (10 to 440V AC/DC) and frequency (15.3 to 450Hz)
• installation insulation measurement at 500V
• standard earth connection resistance measurement (1 stake + loop method)
• PE conductor continuity test
• measurement of internal loops
• testing of RCDs up to 500mA (exact tripping time and current)
• phase rotation testing

 

DIGITAL INSULATION MEGOHMMETER 1000V CHAUVIN ARNOUX CA6523

• insulation: up to 2G? at 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph


RCD TESTER CHAUVIN ARNOUX CA6030

• Direct, safe connection to installation mains
• Automatic installation voltage and frequency measurement
• Tests standard, selective, A and AC RCDs
• 5 fixed calibres 10/30/100/300/500mA + 1 calibre adjustable from 6 to 650mA
• Checks RCD trips / trip time measurement (pulse or ramp mode) and exact trip current (ramp mode)

 

EARTH GROUNDING RESISTANCE TESTER CHAUVIN ARNOUX CA6462

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

EARTH GROUND RESISTANCE TESTER CHAUVIN ARNOUX CA6460

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

INSULATION MEGOHMETER 1KV CHAUVIN ARNOUX CA6543

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plottingof the R(t) curve
• automatic indication of voltage before and after measurement: 1 to 1,000V AC/DC
• resistance: 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation )

 

EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6470N TERCA3

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods

 

ELECTRICAL MACHINE CERTIFICATION TESTER CHAUVIN ARNOUX CA6160

• dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2)
• continuity: up to 100O with 0.1 < ITEST < 25A
• voltage drop: up to 100V (Itest > 10A)
• insulation resistance: up to 1GO at 250/500VDC and 1,000VDC
• measurement of internal and external discharge time (at the plug)
• leakage current: operating and residual up to 20mA, contact up to 2mA
• functional testing: voltage, current, frequency and power

 

DIGITAL INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6533

• insulation: up to 20G? at 50V, 100V, 250V and 500V
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• resistance: 0 to 400kO
• giant 4,000-count display + bargraph
• backlit display
• programmable alarms


ANALOGUE MEGOHMMETER 1000V CHAUVIN ARNOUX CA6513

• insulation: up to 1,000MO (1 cal.) at 500V and 1,000V DC
• AC voltage: 0 to 600V
• resistance: 0 to 1,000O
• continuity: -10O to +10O (I=200mA)
• automatic testing of voltage absence by direct measurement