Digital Insulation Megohmmeter 5kV Chauvin Arnoux CA6547

Code: Chauvin Arnoux CA6547


 

Datasheet PDF, 0.72 Mb

Description

In its site-proof case, the C.A 6547 megohmmeter can be used for quantitative and qualitative analysis of insulation. It also automatically measures voltage, capacitance and residual current.

In addition, this model offers memorisation of measurements and an RS 232 link for controlling the instrument and processing the data using computer software.

 

 

  • wide range from 30k? to 10T? !
  • 4 fixed test voltages: 500 / 1,000 / 2500 and 5,000V
  • programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V
  • giant backlit LCD screen with digital display + bargraph
  • qualitative analysis of insulation: automatic calculation of DAR, PI and DD (dielectric discharge) ratios and plotting of the R(t) curve
  • numerous functions: programmable test duration, lock-in of test voltage, smooth function, programmable alarms, etc.
  • memorisation of several thousand measurements
  • RS 232 connector for link-up to a PC (MEGOVIEW processing software)

 

 

Standard accessories

C.A 6547 Megohmmeter .................................... P01139702

C.A 6549 Megohmmeter .................................... P01139703

Delivered with a carrying bag containing:

½ 2 safety leads 3 m long with HV plug and HV crocodile clip (red/blue)

½ 1 guarded safety plug 3 m long with an HV plug with rear connection

and an HV crocodile clip (black)

½ 1 lead with rear connection (blue) 0.35 m long

½ 1 mains power cable 2 m long,

½ 1 communication lead,

½ 1 simplified operating manual

½ 1 operating manual in 5 languages

 

More products CHAUVIN ARNOUX

ANALOGUE MEGOHMMETER 1000V CHAUVIN ARNOUX CA6513

• insulation: up to 1,000MO (1 cal.) at 500V and 1,000V DC
• AC voltage: 0 to 600V
• resistance: 0 to 1,000O
• continuity: -10O to +10O (I=200mA)
• automatic testing of voltage absence by direct measurement


EARTHING RESISTANCE TESTER CHAUVIN ARNOUX CA6470N TERCA3

• extensive measurement ranges: 0.001? to 100 k?
• adjustment of the measurement frequency between 41 Hz and 512 Hz
• 10 times greater accuracy due to its 4-pole measurement method
• measuring soil resistivity
• calculate r automatically by the Wenner or Schlumberger methods

 

THREE-PHASE POWER QUALITY ANALYZER CHAUVIN-ARNOUX CA8435

• C.A 8435, the rugged, waterproof IP67
• Indoor and outdoor use, even when it is raining
• 5 voltage inputs, 4 current inputs
• Continuous recording of all the parameters simultaneously
• Monitoring with alarms
• All types of installations
• Measurement of P, Q, S and D power values (total and per phase)
• Calculation of Pst & Plt flicker values

 

INSULATION RESISTANCE MEGOHMMETER 1KV CHAUVIN ARNOUX CA6541

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plotting of the R(t) curve (automatic memorisation of 20 samples)
• automatic indication of voltage before and after measurement: 1 to 1000V AC/DC
• resistance: from 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation)
• automatic measurement capacity after each insulation measurement: 0.005 to 4.999 ½F

 

EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6474

• Ideal for earth measurements on pylons
• measurement range: 0.001 O to 99.99 kO
• resolution: 0.001 to 10 O
• no-load voltage: 16 or 32 VRMS
• measurement frequency: 41 Hz to 5,018 Hz
• measurement of resistance of earth stakes: 0.01 O to 100kO
• leakproofing: IP53

 

ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6114

• automatic installation status test immediately after connection
• measurement of voltage (10 to 440V AC/DC) and frequency (15.3 to 450Hz)
• installation insulation measurement at 500V
• standard earth connection resistance measurement (1 stake + loop method)
• PE conductor continuity test
• measurement of internal loops
• testing of RCDs up to 500mA (exact tripping time and current)
• phase rotation testing

 

INSULATION MEGOHMETER 5KV CHAUVIN ARNOUX CA6505

• Adjustable test voltage: 40 V to 5,100 V in 10 or 100 V increments
• 500 V: 10 kO to 2 TO
• 1,000 V: 10 kO to 4 TO
• 2,500 V: 10 kO to 10 TO
• 5,000 V: 10 kO to 10 TO

 

MULTIFUNCTION ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6116

• ALL-IN-ONE tool for electrical installation testing
• compliance with the national and international standards (IEC 60364-6, NF C 15-100, VDE 100, XP C 16-600...
• design, ergonomics, simplicity, rapidity and accuracy
• Suitable for all types of neutral systems (TT, TN, IT)
• large backlit graphic screen

 

EARTH GROUND RESISTANCE TESTER CHAUVIN ARNOUX CA6460

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

EARTH RESISTANCE TESTER CHAUVIN ARNOUX CA6421

• earth resistance: 0.5Oat 1,000 O (log scale) )
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• removable captive connection strip between S and H for 2-wire resistance measurements