Digital Insulation Megohmmeter 1kV Chauvin Arnoux CA6525

Code: Chauvin Arnoux CA6525


 

Description

Particularly innovative and user-friendly, the C.A 6525 insulation tester is ideal for testing electrical installations and equipment:

 

  • insulation: up to 2G? at 250V, 500V and 1,000V DC
  • voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
  • continuity: -20? to +20? (audible beep and compensation of leads)
  • resistance: 0 to 400k?
  • giant 4,000-count display + bargraph (simultaneous reading of the measurement and analogue variance)
  • backlit rear display
  • programming of alarms
  • timer function (0 to 15min)
  • remote control probe available as an option
  • back stand for use on a table or on the ground
  • long battery life: 6 x 1.5V batteries
  • Measurements in compliance with IEC 61557, NF C 15-100, VDE 0413
  • electrical safety: IEC 1010 600V Cat. II
  • dimensions: 211 x 108 x 60mm; weight: 830g

 

 

Standard accessories

C.A 6521...................P01140801D

C.A 6523...................P01140802D

C.A 6525...................P01140803D

 

½ 1 ½hands-free½ carrying case

½ 1 pair of 1.5 m leads, red + black

½ 1 red croc-clip

½ 1 black test probe

½ 6 LR6 batteries

½ 1 set of operating instructions

 

More products CHAUVIN ARNOUX

RCD TESTER CHAUVIN ARNOUX CA6030

• Direct, safe connection to installation mains
• Automatic installation voltage and frequency measurement
• Tests standard, selective, A and AC RCDs
• 5 fixed calibres 10/30/100/300/500mA + 1 calibre adjustable from 6 to 650mA
• Checks RCD trips / trip time measurement (pulse or ramp mode) and exact trip current (ramp mode)

 

THREE-PHASE ENERGY ANALYZER CHAUVIN-ARNOUX CA8335 QUALISTAR PLUS

• - Voltage ratios: 1 V to 500 kV
• - Mixed sensors: 10 mA to 60 kA depending on sensor
• for quick verification of network quality and simple processing of the results

 

DIGITAL INSULATION MEGOHMMETER 5KV CHAUVIN ARNOUX CA6549

• measurement range: 10k? to 10T?!
• 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000V
• adjustable test voltage position: 40 to 5,100V in 10V or 100V increments
• step voltage mode: R(Utest) measurement curve viewed on the screen and gradient calculated automatically in ppm/V
• DAR, PI and DD quality ratios calculated automatically
• programmable test length and R(t) measurement curve

 

INSULATION MEGOHMETER 1KV CHAUVIN ARNOUX CA6543

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plottingof the R(t) curve
• automatic indication of voltage before and after measurement: 1 to 1,000V AC/DC
• resistance: 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation )

 

MULTIFUNCTION ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6116

• ALL-IN-ONE tool for electrical installation testing
• compliance with the national and international standards (IEC 60364-6, NF C 15-100, VDE 100, XP C 16-600...
• design, ergonomics, simplicity, rapidity and accuracy
• Suitable for all types of neutral systems (TT, TN, IT)
• large backlit graphic screen

 

INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6511

• insulation: up to 1,000MO (1 cal.) at 500V DC
• AC voltage: 0 to 600V
• continuity: -10? to +10? (I=200mA)
• automatic testing of absence of voltage by direct measurement
• single input on two colour-coded terminals


EARTH RESISTANCE TESTER CHAUVIN ARNOUX CA6421

• earth resistance: 0.5Oat 1,000 O (log scale) )
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• removable captive connection strip between S and H for 2-wire resistance measurements


DIGITAL INSULATION MEGOHMMETER 5KV CHAUVIN ARNOUX CA6547

• wide range from 30k? to 10T? !
• 4 fixed test voltages: 500 / 1,000 / 2500 and 5,000V
• programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V
• giant backlit LCD screen with digital display + bargraph
• qualitative analysis of insulation: automatic calculation of DAR, PI and DD (dielectric discharge) ratios
• plotting of the R(t) curve

 

DIGITAL INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6521

• insulation: up to 2G? at 250V and 500V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep)
• giant 400-count display + bargraph (simultaneous reading of measurement and analogue variance)
• back stand for use on a table or on the ground
• long battery life: 6 x 1.5V batteries


DIGITAL INSULATION MEGOHMMETER 1000V CHAUVIN ARNOUX CA6523

• insulation: up to 2G? at 500V and 1,000V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep and compensation of leads)
• resistance: 0 to 400k?
• giant 4,000-count display + bargraph